Sentiotec STP-INFACE-T User manual

INSTRUCTIONS MANUAL
TOUCH CONTROL INTERFACE
STEAM GENERATOR
FOR
STP

IMPORTANT
Factory Reset is a must after
installing steam generator for the
first time. Refer to point 3.5.13,
page 6.
Table of Contents
1. Introduction
2. Installing the Control Unit
3. OFF Mode
3.1 ON/OFF Button
3.2 Current Day & Time
3.3 Light
3.4 Hidden Button
3.5 Settings Menu
3.5.1 Day & Time
3.5.2 Kilowatt Value
3.5.3 Counters
3.5.4 Autodrain
3.5.5 Decalcifying
3.5.6 Blackout Memory
3.5.7 Temperature Scale
3.5.8 Standby Temperature Setting
3.5.9 Auto Set Light
3.5.10 Auto Set Fan
3.5.11 Software Version
3.5.12 LCD Contrast
3.5.13 Factory Reset
3.5.14 Save and Exit
3.6 Preset Time Settings
4. ON Mode
4.1 Steam ON
4.2 Day and Session Time
4.3 Temperature Setup
4.4 Optional Features
4.4.1 Aroma
4.4.2 Dimmer
4.4.3 Fan
1
2
3
3
3
3
3
4
4
4
4
5
5
5
5
5
5
6
6
6
6
6
7
8
8
8
8
9
9
9
9
5. Standby Mode
4.1 Current Day and Standby Time
4.1 Pause Button
6. Drain Mode
7. Easy Mode
7.1 Hidden Button
7.2 Steam ON
8. Steam Generator DIP Switches
8.1 Standby Time
8.2 Session Time
8.3 First Block of 8 Switches
8.4 Dip switches for Naming Slaves
8.5 Dip switches for Other Functions
9. Control Panel DIP Switches
10. Remote and Alarm Connections
10.1 Emergency Alarm
10.2 Remote ON
11. Maintenance
11.1 Decalcification
12. Troubleshooting
12.1 For Tandem Connection
12.2 Error Codes
10
10
10
10
11
11
11
12
12
12
12
12
12
13
14
14
14
15
15
16
16
16

Indicators
1. Introduction
There are five different operation modes in the unit: OFF, ON, Standby, Easy
Mode and Drain. The user can easily switch between different modes making
the steam bathing more convenient.
To use the steam room, the control unit needs to be in ON Mode. In the ON
mode, the steam generator is producing steam and temperature in the steam
room is kept in preferred set temperature with occasional discharge of steam.
However, if the steam room is not used constantly, the generator can be set to
Standby Mode. During the Standby Mode, water and steam room are kept
warm with minimal energy consumption. The generator is able to produce
steam shortly after the unit is switched back to ON mode for the user’s
convenience.
Steam ON (Animated) Light ON (Animated)
Dimmer - optional feature
Fan ON (Animated)
- optional feature
Aroma ON (Animated)
- optional feature
1
Indicators
Keylock is on.
Preset time is activated. Refer to point 3.5.14.
Heating element error icon shows if there is a problem with
the heating elements. Refer to Factory Reset point 3.5.13.
{

Run the Factory Reset after installing the steam
generator for the first time or after changing the
control panel. Refer to point 3.5.13.
2. Installing The Control Unit
152 mm
77 mm
Check the most suitable area to place your steam generator control. The control and
the steam generator should be accessible for the user and for maintenance. Do not
install the control unit inside the steam room! The cable connecting the control
unit and the steam generator is 7.5 meters long.
Never attempt to modify or fix the steam control. Contact your licensed technician or
your nearest service center for repair.
Before installation, main power supply of the generator must be switch off from the
circuit breaker.
Mount the control unit in the wall according to the specifications given below. Follow
the illustrations.
2
Insert the metal casing
into the hole. Bend the
locks on the sides to
hold the casing still. If
not possible because of
a thick wall, screw the
casing into the wall.
Snap-in the control panel into
the metal casing to lock.
For maintenance, pull out the
control panel using a flat screw
driver or similar.
Locks
1
2
Metal
Casing
Control
Panel
(Cut)
1 3
2 4

ON
Current Day and Time Light
FanSettings Menu
3.1 ON/OFF
Button
3.3 Light Button
3. OFF Mode
Pressing shortly the ON button will switch the steam generator
ON. Temperature and session-time setting is automatically set
based on the saved settings from the previous session. To
change the settings, press the Settings Menu.
Switch OFF the display by pressing for the ON/OFF button 3
seconds. Tap the display to turn it on.
3.2 Current Day
& Time Button Day and Clock button is displayed in the OFF Mode. It shows the
current day and time.
Long press the button to jump into Pre-Set Time setup. Refer to
Pre-set time setting at point 3.6.
Toggle the light button to switch ON/OFF your steam room lights.
When your steam generator has a dimmer feature you can adjust
the brightness from 0-100%. Dimmer setting appears when you
turn on the light or long press the light button while light is on.
Hidden Button
3.4 Hidden
Button The hidden button is the gateway to Easy Mode. Long press 10
seconds to activate the Easy Mode. 3

Confirm to reset
Long press Reset button
3.5 Settings Menu and Keylock
3.5.1 Day and Time
The Settings Menu is only available in the OFF State.
Press not less than 5 seconds and release the button to enter
setup. A beeping sound will signal the change of menu status.
Here you may preset session time, temperature, fan, light,
perform steam generator maintenance and access to useful
information about your steam control system.
To lock/unlock screen, press more than 10 seconds the Settings
Menu button. Lock icon will appear on the display.
Select the day and time by pressing the day, hour
and minute button. Change values by short or
long pressing the buttons. Long pressing hour or
minute button will change numbers faster.
3.5.2 Kilowatt Value Set the correct kilowatt value of the steam
generator to the control (see kilowatt information
on your steam generator). Press the arrow up or
down to select. The default kilowatt value setting
at 7.5.
3.5.3 Counters Counters display the usage of time and kilowatt of
the steam generator. This information is very
necessary to evaluate the need of a preventive
maintenance and compute electricity
consumption.
Pressing the Reset button will reset the ON hours
and kWh counters. Previous data cannot be
retrieved after resetting the counter.
Press reset button for 10 seconds to display the
actual usage information. This usage counter
cannot be erased. It shows usage of the control
panel since the manufacturing date.
ACTUALUSAGE
4

3.5.4 Autodrain
The autodrain is set to ON by default. For manual
drain, select OFF to deactivate the function.
When autodrain is ON, it will automatically drain the
water inside the steam generator tank after use. In
case of power interruption, it will continue to drain
when detecting a high water level in the tank.
Bold outline means selected.
3.5.5 Decalcifying
Decalcifying function is very useful for maintenance.
This function requires autodrain.
Read more information on how to decalcify your
steam generator tank in page 15.
Active Blackout Memory restores control to its
previous state before power failure. For example, if
steam generator was on before power failure, the
steam generator will automatically continue from the
previous state.
You may set the temperature scale either Celsius or
Fahrenheit.
Steam room temperature will be maintained during
Standby Mode. Standby temperature can be set from
00C to 450C.
5
The light can be set as auto ON or OFF. When the
light is set to auto ON the light will switch ON when
the steam generator is in ON or Standby mode.
3.5.9 Auto Set Light
3.5.6 Blackout Memory
3.5.7 Temperature Scale
3.5.8 Standby Temperature Setting

3.5.11 Software Version
Software version has two parts, Interface Software
Version and the Controller Board Version.
3.5.12 LCD Contrast Setting
You can adjust the contrast of the display between 0
and 100.
Press the HeE RESET to remove heating element
error after checking or fixing the heating elements. If
steam generator’s kW is changed, press reset button
instead.
Pressing the RESET button will revert all settings to
factory default. This is used when there is a
malfunction on the machine or you wish to clear
previous settings. Factory reset does not reset on
hours and kWh counters.
Once everything has been set, you may press SAVE
to save all the setup or ESC if you wish to abort the
settings.
Auto fan turns on the fan once control goes to Off
Mode to dry out the steam room. Fan will remain on
for selected time. You may adjust the time from 0 - 24
hours with 15minute intervals. Auto fan is activated
only when the animated Auto button is displayed on
the screen.
01:15
6
3.5.10 Auto Set Fan
3.5.13 Factory Reset
3.5.14 Save and Exit

3.6 Preset Time Settings
This can be switched OFF/ON. A small icon appears on
the screen indicating that the Preset Time is activated.
Press ON to set preset time. When presetting time, you
can set the day and time for your steam session.
Long press to activate the Preset Settings
Preset activated
Darkened area is the active area that can be modified.
Press arrows left or right to change settings. Tap the
active area to jump into next setting. When start time
and end time are same, there is no steam session.
Maximum session time depends on the dip switch
setting on the steam generator. (See Steam Generator
DIP switches at page 12).
Three-arrow button copies settings from the day on the
left to the day on the right. Press OK when all is set.
7
Current Day and Time
Preset Time

Steam ON
Day and Session Time Light - Dimmer (Optional)
Fan (Optional)
Room Temperature
4.1 Steam ON The steam generator produces steam during ON mode. In
this mode, you will find the steam button animated,
indicating that the steam session is ongoing.
Short press the Steam ON button to switch on Standby
Mode. Long press the steam button to switch OFF. If
autodrain is present, steam generator goes to Drain Mode
and turns off after draining.
4.2 Day and Session Time The day indicates current day which can be set in the Day
and Time setup in Settings Menu.
Session time is the remaining time of using the steam room.
The session time can be set until 24hours and it counts
down.
When Day and Session button is pressed, a setup screen
will appear. Use arrows up and down to change the session
time and hit OK when values are set.
Maximum length of the session time can be set on the DIP
switches. (See Steam Generator DIP switches on page 12).
4.3 Temperature Setup The temperature button indicates either the actual or target
steam room temperature (refer to Control Panel DIP
switches page13). Press the up and down arrow keys to
change the temperature settings inside the steam room.
8
4. ON Mode