Sensit HXG-2d User manual

851 Transport Drive • Valparaiso, IN 46383 (USA)
Phone: 219.465.2700 • www.gasleaksensors.com
Combustible Gas Detector
INSTRUCTION MANUAL
SENSIT®HXG-2d
Read and understand instructions before use.
Intrinsically Safe for Use in
Class I, Groups C and D, T3
Hazardous Locations
For use in clean dry areas only.
Suitable for combustible gases such as Methane,
Butane, Propane and Natural Gas
710183
UL 913

⚠WARNING: Do not replace batteries when an explosive atmosphere is present.
⚠WARNING: Use only DURACELL® PROCELL, Type PC1400 Alkaline Batteries
⚠WARNING: Do not mix batteries of different age or type.
⚠WARNING: For use in clean dry areas only.
⚠WARNING: Not for use in atmospheres of oxygen greater than 21%.
⚠WARNING: Substitution of components may impair intrinsic safety.
⚠WARNING:ONLY zero instrument in a gas free environment.
⚠WARNING: To maintain intrinsic safety, service must be performed by factory authorized
technicians with approved replacement parts only.
⚠WARNING: All Accessories are to be used in an area known to be non-ammable.
⚠WARNING: Use only sensor from SENSIT Technologies. PN 375-2611-01
NOTE: Performance/Accuracy aspects of this product have not been assessed and are not
covered as a part of the SGS approval.
FOR YOUR SAFETY
NOTICE
⚠CAUTION: This safety symbol is used to indicate a potentially
hazardous situation which, if not avoided, may result in minor or
moderate injury.
⚠WARNING: This safety symbol is used to indicate a potentially
hazardous situation which, if not avoided, may result in serious injury.
ii

3
CONTENTS
Preparation
For Your Safety.............................................................. ii
Parts and Accessories...................................................4
General Description.......................................................5
Sensor Specications....................................................6
Product Features....................................................... 7-9
Sensor Type ................................................................10
Basic Operation
Battery Installation/Replacement.................................11
Operation and Use ................................................ 12-14
Calibration Check ........................................................15
Calibration ............................................................. 15-16
Sensor Replacment.....................................................17
Adjustable Features.....................................................18
Options Menu ........................................................ 19-21
Warranty ....................................................... Back Cover

4
PARTS AND ACCESSORIES
Standard Accessories (Included)
Soft Carrying Pouch 360-00006
T10 Torx Wrench 360-00105
Duracell “C”Alkaline Battery (ea) 310-00004*
Wrist Strap 360-00040
Instruction Manual 750-00022
Accessories and Replacement Parts
LEL Sensor 375-2611-01
Sensor Cap with Filter Disc 882-00036
Filter Disc Replacement 360-00203
Extension Adapter 870-00012
Calibration Kits
Methane Calibration Kit
2.5% Methane/Air (21L), Regulator, Hose 881-00017
Propane Calibration Kit
1.1% Propane (21L), Regulator, Hose 881-00073
Replacement Gas Cylinders
2.5% Methane/Air (21L) 315-080012
1.1% Propane/Air (21L) 315-080022
Contact Factory for additional options.

GENERAL DESCRIPTION
The SENSIT® HXG-2d is designed to detect combustible gases. This
instrument incorporates an advanced low power semiconductor sensor to
measure a wide variety of combustible gases in both the PPM and %LEL
range. The PPM readings auto-range to %LEL when the concentration
exceeds 990PPM (2%LEL methane or 4.5%LEL propane).
Optionally all readings can be set to a resolution of 0.1%LEL only (PPM
off). An “on demand” backlight allows use in dark environments. A user
activated “TICK” control assists in locating small gas leaks.
Audible and visual alarms warn the operator of hazards. The alarms can
be set in either the PPM or LEL modes. The default alarm is 10%LEL
methane/propane.
The instrument is adjusted at the factory for either methane or propane
as the primary gas, and is calibrated accordingly. The primary gas can be
selected when ordering.
The SENSIT® HXG-2d meets US UL913 requirements when used with
approved batteries.
The SENSIT® HXG-2d is operated using approved alkaline batteries
only.
⚠ Warning: Never mix batteries of different age or type.
5

SPECIFICATIONS
SENSOR SPECIFICATIONS
TYPE RESOLUTION RANGE ACCURACY
PPM 10ppm 0-990ppm ±10%
LEL 0.1%. 0-100%LEL ±10%
PRODUCT SPECIFICATIONS
Size: 10” x 3” x 1.6” (254 x 76 x 41 mm)
Weight: 1.2 lbs. (544 g)
Operational Temp: -20° to 40° C (-4 to 104° F)
Battery Life: Alkaline: 50 hours continuous
6
The SENSIT® HXG-2d meets US UL913 requirements
when used with Duracell PC1400 batteries.
Intrinsically Safe for Use in Class I,
Groups C and D, T3 Hazardous Locations
For use in clean dry areas only.
710183
UL 913

7
PRODUCT FEATURES
SENSOR
ALARM LED
GRAPHIC DISPLAY
OPERATION BUTTONS
ELECTRONIC TICK CONTROL
FLEXIBLE GOOSENECK
BATTERY COMPARTMENT

8
PRODUCT FEATURES
SENSIT® HXG-2d instruments are constructed of durable high impact
ABS to withstand the rigors of eld use.
Incorporated in the hand grip area is the battery compartment. All
SENSIT® HXG-2d instruments require 3. Duracell PC1400 batteries
provide approximately 50 hours of continuous use.
A push button located in the center of the instrument activates an
audible tick sound that will help in locating the source of a gas leak. This
tick is generated by using specialized circuitry in combination with the
LEL sensor located at the end of the gooseneck assembly. The tick can
be easily heard with the speaker located in the back of the instrument.
A exible gooseneck is used to assist in locating the source of gas leaks
and remote sampling.
The display continuously updates the operator of changes in gas
concentrations and alerts of low battery power.
A green LED on the left side indicates the instrument is ready for use. A
red LED indicates the preset alarm points have been exceeded.

9
PRODUCT FEATURES
There are 3 operational button pads on the front of all SENSIT® HXG-2d
instruments.
BUTTON (A) POWER/MUTE
Operates the POWER and MUTE features and exit menu items.
BUTTON (B) TICK/CAL
Use to operate TICK or begin calibration.
BUTTON (C) LIGHT/ZERO
Use to turn on the backlight or manually zero the sensor.

10
SENSOR TYPE
COMBUSTIBLE GAS SENSOR
All SENSIT® HXG-2d instruments incorporate a highly sensitive
semiconductor type sensor. The function and accuracy of the sensor are
monitored and controlled by specialized circuitry and a microprocessor.
This sensor is capable of measuring concentrations of 10ppm of
methane/propane up to 100% LEL. Factory calibration uses methane
or propane depending on preset gas type.. This sensor will detect many
combustible gases.
SENSOR FILTER REPLACEMENT / CLEANING
Remove sensor cap by pressing retaining tab located on side of sensor
and pulling the cap away from base. Filter will be loose inside. Clean
lter with mild soap and water and thoroughly dry lter cap. Replace
Cap/Filter on base until retaining tab engages.
NOTE: Operating the instrument without a sensor cap or with an altered
sensor cap can cause damage to the instrument and void the warranty.
Other manuals for HXG-2d
2
Table of contents
Other Sensit Security Sensor manuals

Sensit
Sensit HXG-2d User manual

Sensit
Sensit TKX User manual

Sensit
Sensit VMD Operating instructions

Sensit
Sensit HXG-2d User manual

Sensit
Sensit HXG-3P User manual

Sensit
Sensit RLD-2 User manual

Sensit
Sensit HXG-3 User manual

Sensit
Sensit CO Programming manual

Sensit
Sensit PMD2 User manual

Sensit
Sensit TKX User manual