SECO-LARM SK-1011-SDQ User manual

Indoor Access
Control Keypad
SK-1011-SDQ
Installation Manual
The ENFORCER SK-1011-SDQ is a single-output, indoor access control keypad that doesn't
scrimp on the important features. It supports up to 1,000 users and 50 temporary visitors and can
be surface mounted with the included back box or flush mounted in a standard single-gang back
box. It includes a tamper alarm, and a backlit keypad for ease of use at night or in dark areas.
12~24 VDC/VAC Auto-adjusting operation
Up to 1,000 possible user codes (000~999)
Up to 50 (01~50) possible temporary visitor codes, which can be programmed for one-time or
limited-time use (1~99 hours)
Form C relay, 1A@30VDC max. can be programmed to activate for up to 99,999 seconds
(nearly 28 hours)
Tamper output N.C. Dry contact, 50mA@24VDC max.
Mounts to a standard single-gang back box (surface-mount back box included)
All features are programmed directly from the keypad with no need for an external programmer
EEPROM Memory protects programmed information in case of power loss
Egress input lets users exit the premises without keying in the code
Data I/O terminal for split-series setup providing added security
Expansion port for future optional features
Always-on backlit keypad

Indoor Access Control Keypad
2 SECO-LARM U.S.A., Inc.
Quick Installation Guide
This page is for installers looking to do a basic installation and programming of the keypad. For
more in-depth installation and programming instructions, see the Table of Contents on pg. 4. For
optional Split-Series Controller installation and operation instructions, please refer to its manual.
Mounting Diagram
Quick Wiring Diagram
*To protect the relay, you must install the included diode—with the cathode (striped end ) wired toward the positive
side—for DC powered locks unless your lock has a diode built in. AC powered locks and electromagnetic locks require a
varistor/MOV (05D390K or similar, not included) wired in the same location if the lock does not have one built in (all SECO-LARM
electromagnetic locks have built-in protection). Failure to use these as directed will void the warranty.
Faceplate
screws
Mounting
screws x3
12~24 VAC/VDC
Power supply
These terminals
are
for connection to optional
Split-
Series Controller. See controller manual for
installation and connection instructions.

Indoor Access Control Keypad
SECO-LARM U.S.A., Inc. 3
Quick Programming Guide
This page is for installers looking to do a basic installation and programming of the keypad. For
more in-depth installation and programming instructions, see the Table of Contents on pg. 4. For
optional Split-Series Controller installation and operation instructions, please refer to its manual.
Programming Tips
The master code, super user code, and user codes cannot be the same.
A flashing amber LED indicates the keypad is in standby mode.
A solid amber LED indicates the keypad is in programming mode.
If the user code entry mode is set for auto-entry, your user codes will need to be the same
number of digits as the master code (see Programming the User Code Entry Mode, pg. 19).
Programming Instructions
Follow the instructions below if the following covers your needs.
A new master code
A single 4-digit user code for all users
One output to unlock a door
A 3-second delay time in opening the door after the output is activated
1. Turn off the beeping before the 1-minute power-up period ends
2. Enter programming mode
NOTE: The default master code is 0000.
3. Change the master code
NOTE: In the formula above, represents the new master code.
4. Set the user code to operate the output (unlock the door)
NOTE: chooses user ID #000 of 1,000 possible users (000~999).
is the new user code for user ID #1.
5. Set the output delay time (skip this step if the default value of 5 seconds is acceptable)
NOTE: sets the output delay time for 3 seconds.
6. Exit programming mode

Indoor Access Control Keypad
4 SECO-LARM U.S.A., Inc.
Table of Contents
Quick Installation Guide .................................... 2
Mounting Diagram ............................................ 2
Quick Wiring Diagram ....................................... 2
Quick Programming Guide ............................... 3
Table of Contents ............................................. 4
Parts List ........................................................... 4
Specifications ................................................... 4
Overview ........................................................... 5
LED Indicators and Keypad Sounds ................. 5
Installation ........................................................ 6
Important Notes ................................................ 6
Wiring Diagram ................................................. 7
Sample Application ........................................... 7
Getting Ready to Program ................................ 8
Programming Format and Default
Programming Values .................................... 9
System Restore .............................................. 10
Programming the Master Code....................... 10
The Super User Code ..................................... 11
Programming User Codes .............................. 13
Programming Visitor Codes ........................... 14
Programming the Output Mode and
Duration ..................................................... 15
Programming the Real-Time Clock ................ 16
Programming the Auto-Disable Time ............. 17
Programming the Wrong-Code System
Lockup ....................................................... 18
Programming the User Code Entry Mode ...... 19
Programming the Keypad Sounds ................. 19
Programming the Output Relay Activation
Sounds ....................................................... 20
Programming the Amber LED in Standby
Mode .......................................................... 20
Programming the Egress Delay/Warning ....... 21
Direct Access to Programming ....................... 22
Installer Notes ................................................ 23
Users' Guide to Operating the Keypad .......... 24
Warranty and Notices ..................................... 24
Parts List
1x
Keypad
1x
Back box
2x
Faceplate
screws
3
x
Mounting screws
1x
Diode
1x
Manual
Specifications
Operating voltage 12~24 VAC/VDC
Current draw
(@12VDC)
Standby 15mA
Keypress 30mA
Output 1 active 55mA
Total (max.) 90mA
Outputs Output 1, Form C 1A@30VDC
Tamper 50mA@24VDC
Egress input N.O. Ground
Operating humidity 5~95%, non-condensing
Operating temperature -4°~154° F (-20°~70° C)
Dimensions (including back box) 45/8"x27/8"x115/16" (117x73x49 mm)
Weight 6-oz (170g)

Indoor Access Control Keypad
SECO-LARM U.S.A., Inc. 5
Overview
LED Indicators and Keypad Sounds
LED Indicators
Red LED (Left) Amber LED (Center) Green LED (Right)
Steady
Output inhibited Programming mode Output activated
Flashing
Output inhibit paused Standby mode –
Keypad Sounds and Amber LED
Status Sounds* Amber LED (Center)
In programming mode – Steady ON
Successful key entry 1 Beep 1 Flash
Successful code entry 2 Beeps 2 Flashes
Unsuccessful code entry 5 Beeps 5 Flashes
Power up delay Continuous beeping Continuous flashing
Output relay activation† 1-Sec long beep –
In standby mode‡ – 1 Flash/second
System refresh mode 2 Beeps after refresh completed Fast flashing for 2.5 minutes
Code already stored 1 Long beep –
Real time clock stopped after
power loss
Continuous 3 fast beeps
every 5 seconds –
*Keypad sounds can be programmed ON or OFF (see pg. 19).
†Output relay activation sounds can be programmed for 1-second long beep, 2 short beeps, or OFF (see pg. 20).
‡Amber LED flashing during standby mode can be programmed ON or OFF (see pg. 20).
45/8"
(117mm)
115/16"
(49mm)
27/8"
(73mm)
47/16"
(112mm)

Indoor Access Control Keypad
6 SECO-LARM U.S.A., Inc.
Installation
1. Find a suitable location to mount the keypad. Install it at the height at which most users will be
able to easily operate the keypad.
2. Note where the wires will enter and knock out the appropriate opening for running the wires.
3. Install the center mounting screw on the wall. Hang the back box on this screen by the top
"keyhole" mounting hole.
4. Install the remaining mounting screws and tighten all mounting screws in place.
5. Run the wire through the wall or conduit to the back box location, then run the wire into the
back box.
6. Connect the wires to the keypad according to the wiring diagram on pg. 7.
7. Finish assembly by attaching the keypad to the back box with the included faceplate screws.
Important Notes
1. Always disconnect power before servicing the keypad. Do not apply power until all connection
wiring is completed.
2. The keypad must be properly grounded. Use a minimum of 22AWG wire connected to the
ground terminal. Failure to do so may damage the keypad.
3. All wiring and programming should be done by a professional installer to reduce the risk of
improper installation.
4. The user’s guide for this keypad is located on pg. 24 of this manual.
5. Be sure to store this manual in a safe place for future reference.
Faceplate
screws
Mounting
screws x3
IF USING THE KEYPAD WITH A MECHANICALLY
OPERATED DOOR OR GATE, MOUNT THE KEYPAD AT
LEAST 15’ (5m) FROM THE DOOR OR GATE TO PREVENT
USERS FROM BEING CRUSHED OR PINNED. FAILURE TO
DO SO MAY RESULT IN SERIOUS INJURY OR DEATH.

Indoor Access Control Keypad
SECO-LARM U.S.A., Inc. 7
Wiring Diagram
Sample Application
Stand-Alone Door Lock
In this application, the keypad is connected to a single door lock and an egress pushbutton.
*To protect the relay, you must install the included diode—with the cathode (striped end ) wired toward the positive
side—for DC powered locks unless your lock has a diode built in. AC powered locks and electromagnetic locks require a
varistor/MOV (05D390K or similar, not included) wired in the same location if the lock does not have one built in (all SECO-LARM
electromagnetic locks have built-in protection). Failure to use these as directed will void the warranty.
Connection Terminals
Terminal Description
Tamper N.C.
Tamper switch output, N.C. contact, max.
50mA@24VDC. Connect to the N.C. 24-hour
protection zone of an alarm if needed.
12~24
VAC/VDC
Connect to a 12~24 VAC/VDC power supply.
Observe polarity.
Relay
Output
N.C.
1A@30VDC max. COM
N.O.
Egress In N.O. Pushbutton contact to ground. Press
button to initiate door unlock output.
Data I/O For use with optional Split-Series Controller
Ground Additional ground (–)
Connection Terminals
Connection Terminals Expansion Port
12~24 VAC/VDC
Power supply
These terminals
are
for connection to optional
Split-
Series Controller. See controller manual for
installation and connection instructions.

Indoor Access Control Keypad
8 SECO-LARM U.S.A., Inc.
Getting Ready to Program
Keypad Codes
There are four types of keypad codes.
Master code – Used only for entering programming mode; there can be only one master code
per keypad.
Super user code – Can be used to activate the output, or to disable (inhibit) or enable the
operation of the output.
User codes – Unique codes for each user to activate the output.
Visitor codes – Temporary codes that can be assigned to visitors or temporary workers to
activate the output; the visitor codes can be programmed for one-time use or to expire after a
set number of hours has passed.
Power Up the Keypad
When the keypad is first powered up, it will beep continuously for about 1 minute. During this
power-up time, if needed, use direct access to programming (DAP) to reset the master code (see
Direct Access to Programming on pg. 22).
1. Turn off the beeping before the 1-minute power-up period ends
This will immediately stop the beeping. When the beeping has ended, the keypad is ready for
normal operation or for programming.
Enter and Exit Programming Mode
All programming of the keypad is done in programming mode.
1. Enter programming mode
NOTE: In the formula above, represents the master code. The default master
code is "0000" (see Programming the Master Code on pg. 10 to program a new master
code). The amber LED will change to steady ON to indicate that the keypad is in
programming mode.
2. Exit programming mode
The entry can be used to exit programming mode at any time while programming. The
amber LED will return to flashing, indicating standby mode, upon exiting programming mode.
NOTE: DO NOT DISCONNECT THE KEYPAD FROM POWER WHILE IN PROGRAMMING
MODE. Disconnecting the keypad while in programming mode could cause a keypad
memory error.

Indoor Access Control Keypad
SECO-LARM U.S.A., Inc. 9
Programming Format and Default Programming Values
In this manual, the format used for programming the keypad is as follows.
A 2-digit ( ) FUNCTION identifier to tell the keypad what is being programmed.
A varying number of digits ( ) represents the parameters of that FUNCTION.
Press the key to confirm programming of the FUNCTION.
The following is a list of the different programming functions.
Function Parameters
Default functions and values
Page #
01 Master code Default 0000, code length from 4~8 digits 10
02 Super user code No default, must be programmed 11
10 User codes No default, must be programmed 13
40 Visitor codes No default, must be programmed 14
51 Output mode and duration 5-Second output, momentary 15
55 System real-time clock No default, must be programmed 16
56 Auto-disable time No default, must be programmed 17
60 Wrong-code system lock-up Locks keypad after 10 false code/card tries 18
70 User code entry mode Manual entry of "#" after each code 19
71 Keypad sounds Programming and operation beeps enabled 19
72 Output relay activation sounds 1-Second beep when output is activated 20
73 Amber LED standby flashing Center LED flashes on standby 20
90 Egress delay/warning/alarm Egress output happens immediately 21
NOTE The direct access to programming (DAP) code 2828 (see pg. 22) and the system restore
code 9999 (see pg. 10) are fixed and cannot be changed, even via programming.

Indoor Access Control Keypad
10 SECO-LARM U.S.A., Inc.
System Restore
System restore will reset all programming values except the master code back to the default values
shown on pg. 9.
1. Make sure the keypad is in programming mode (see Enter and Exit Programming Mode on
pg. 8).
2. Initiate system restore.
NOTES
System restore will reset ALL programming except the master code back to default values. Be
careful to use system restore only when absolutely necessary.
System restore may take several minutes. The amber LED will flash rapidly during this time.
Once system restore has been completed, the keypad will beep twice to show that all
programming values have been reset to their default values and are ready to be
reprogrammed.
At this point, the keypad is still in programming mode.
Programming the Master Code
The master code is used to enter programming mode. The master code does not serve as a user
code for activating the output.
1. Make sure the keypad is in programming mode (see Enter and Exit Programming Mode on
pg. 8).
2. Enter new master code.
NOTES
represents the new master code, which can be 4 to 8 digits long.
There can be only one master code for the keypad.
Programming a new master code will overwrite the previous master code.
If the master code is forgotten, use direct access to programming (DAP) to reset the master
code (see pg. 22).
The master code, super user code, and user codes cannot be the same.
If the keypad is set for auto-entry mode, user codes will need to be the same number of digits
as the master code (see Programming the User Code Entry Mode on pg. 19).
Other manuals for SK-1011-SDQ
1
Table of contents
Other SECO-LARM IP Access Controllers manuals

SECO-LARM
SECO-LARM SK3133-PPQ User manual

SECO-LARM
SECO-LARM ENFORCER SLI SK-B141-PQ Original operating instructions

SECO-LARM
SECO-LARM ENFORCER Wireless RF Request-to-Exit Buttons... User manual

SECO-LARM
SECO-LARM Enforcer SK-1011-SQ User manual

SECO-LARM
SECO-LARM ENFORCER SD-9963-KSGQ User manual

SECO-LARM
SECO-LARM SK-1011-SDQ User manual

SECO-LARM
SECO-LARM ENFORCER SK-B241-PQ Service manual

SECO-LARM
SECO-LARM ENFORCER SLI PR-B1124-PQ Installation manual