Sealey PPHY User manual

CAT IV 1000V HIGH VOLTAGE TESTER
HYBRID VEHICLES
MODEL NO: PPHY
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING! Please read manual carefully before any operation. This manual includes safety warning and safety requirement, which
help user to operate the equipment safely.
9After measuring AC/DC voltage source for 3 minutes, the tester must take a rest for 1 minute.
8 Nevermeasurethevoltagebeyondspecied(1000V).
8DO NOToperatetheequipmentnearammablegasses.
8DO NOT operating the equipment with wet hands.
9 Keephandsandngersbehindthebarriersduringmeasurements.
8DO NOT unlock and open the battery case during measurements.
9 Conrmthefunctionoftheequipmentwithaknownsourcebeforemeasureunknownvoltagesource.
8DO NOT make any measurement when there is abnormal condition, such as broken case or exposed metal parts are present an the
instrument, test probes, and cables.
8DO NOT modify the equipment.
9Take extreme caution when operating with a live circuit.
9 LEDonlyfunctionproperlywhentemperatureisbetween0~50°C.
9Before using a voltage detector with audible indicator at locations with a high background noise level, it has to be determined
whether the audible signal is perceptible.
2. INTRODUCTION
ProfessionaltwopolevoltagetesterCATIV1000Vforcheckinghigh
voltage on electric/hybrid vehicles. Suitable for checking AC mains and
DCpowersuppliesbetween6-1000VDCand24-1000VAC.Canalso
be used for checking voltage and polarity on car batteries and
continuity testing of DC circuits. Includes a self-test function and
illuminationlight.EN61243-3,IP65,CEcertied.Requires2xAAA
1.5Vbatteries(notsupplied).
3. SPECIFICATION
Model No:.................................................................... PPHY
Accuracy: .............................................................+/-(3%+3)V
CAT Category:..................................................CATIV1000V
IPRating: ........................................................................IP65
Maximum Current:...................................... <3.5mA@1000V
Power:..................................2xAAABatteries(notsupplied)
Voltage: ..................................... 6-1000VDC&24-1000VAC
4. PREPARATION
4.1. POWER ON/ SELF-DIAGNOSTIC
4.1.1. Pressthe“ON/OFF”buttononthemainproberstandthen
onthesecondprobe,shortthetwometalprobes(g.2).The
power will automatically turn on, and the equipment start a
self-diagnostic test.
4.1.2. AllindicatorsonLCDwilllightup(g.3),andbuzzerwillsoundduringthenormalself-
diagnostic test.
8DO NOT operate the equipment if any abnormality occurs during the self-diagnostic test.
4.1.3. LCDwillash5timeswhenbatterypowerislowerthan2.2±0.1V.Pleasechangethebattery.
4.2. TROUBLE SHOOTING
4.2.1. Ifanyofthefollowinghappens,openthebatterycaseandcloseitagainafter5seconds.
Conductaself-diagnostictestafterclosingthecaseagainsee4.1.
Problems:(1)Cannotperformself-diagnostictestbeforeoraftertheoperationoftheequipment.
(2)Cannotautopoweroff.
Main Probe (+)
Second Probe (-)
Illumination Light
Non Contact Voltage Sensor
Non contact voltage indicator
LCD Display
Probe Barrier
Probe Barrier
Light/ Non contact sensing switch
Power Switch
DC positive (+) indicator
DC negative (-) indicator
Probe Clip
Power Switch
g.1
g.2
PPHYIssue118/07/19
Original Language Version
© Jack Sealey Limited
ReferTo
Instructions
Electrical
Shock
Hazard
Wear Eye
Protection
Wear Protective
HighVoltage
Gloves
Warning!: Use
HighVoltage
Safety Mat
Suitable For Live
Working
1 000 V

5. OPERATION
5.1. MEASUREMENT
WARNING! Please read the manual carefully.
9 Performaself-diagnostictesttoinsuretheLCDandbuzzer
function properly.
9Please conform the equipment with a known voltage source.
9When the device is in use make sure hands are behind the probe
barrier.
WARNING!Astheequipmenthashigherimpedance(about
300kΩ),capacitorandinductorvoltagemayindicate.
5.2. AC/ DC POLARITY MEASUREMENT (ON SECOND PROBE)
5.2.1. Connectingtwoprobestotwoportsofthevoltagesource(g.4).
5.2.2. Withoutpressinganybutton,thepolarityofAC/DC(24V-1000V)
will be indicated on the second test probe.
5.2.3. AC:bothpolaritylightsup.(+)DC:DC+lightsupand(-)DC:DC-
lights up.
5.2.4. Thedirectionofthemainprobewilldetermine(+)DCor(-)DC.If
main probe is on the positive port, DC+ lights up, and vice verse.
5.2.5. This function will be cancelled if either of the ON/OFF buttons
are pressed.
5.3. VOLTAGE MEASUREMENT
5.3.1. VOLTAGE AND POLARITY
5.3.2. Connectingtwoprobestotwoportsofthevoltagesource(g.4).
5.3.3. PresstheON/OFFbuttonsonbothprobesatsametime.VoltageandpolaritywillbedisplayedontheLCD.(DC6-1000V;
AC24-1000V;AC/+DC/-DC).
5.3.4. The direction of the main probe will determine DC+ or DC-. If main probe is on the positive port,
DC+ lights up, and vice versa.
WARNING!Ifonlyoneofthebuttonshaspressed,errorvoltagevalueAC23V-AC55Vwillbe
displayedontheLCDwhenvoltageisgreaterthanAC300V.
5.3.5. HIGH VOLTAGE INDICATION
5.3.6. LCD will display“”whenvoltagesource≥100VAC/VDC(g.5).
5.3.7. PHASE ROTATION
5.3.8. Phaserotationmeasurementisonlyfor3phase(4lines)system.Usingtherighthandholdthe
mainprobehandle(behindthebarrier)properlyduringthemeasurement(becauseoneofthe
sensingareasisonthemainprobehandle).
5.3.9. LCD will display voltage between phases.
5.3.10. Iftherotationisclockwise,LCDwilldisplay“R”(g.6).
5.3.11. Iftherotationiscounter-clockwise,LCDwilldisplay“L”(g.7).
5.3.12. Testingtips:Thismeasurementusetesterasavirtualground;ifequipmentoruserisnotwith
proper insulation condition, measurement may not function properly.
5.4. NON-CONTACT VOLTAGE SENSING
5.4.1. To switch on the function, press the “LIGHT/NOT-CONTACT SENSING SWITCH”, LCD will
display “DE-”.
5.4.2. Non-contact voltage indicator“”onthetoprightofthemainprobewilllightupandbuzzer
willsoundwhenthesensorisnearelectromagneticeldgreaterthan90VAC.
5.4.3. Press the “LIGHT/NON-CONTACT SENSING SWITCH” again to switch off the function.
5.4.4. This function will automatically switch off after 3 minutes.
5.5. CONTINUITY
WARNING! Make sure there is no live voltage in the circuit before testing continuity.
5.5.1. Connecting the two probes to the circuit to be tested, press both ‘ON/OFF SWITCH” on two
probes,ifthecircuithascontinuity,allindicatorontheLCDwillash,andbuzzerwillsound.
WARNING! If there is continuity in the circuit, the instrument will perform a self-diagnostic test.
5.6. ILLUMINATION
5.6.1. Longpressandholdthe“LIGHT/NON-CONTACTVOLTAGESENSINGSWITCH”to
switch on the illumination light.
WARNING! Illumination function and non-contact voltage sensing function share the
same button, be aware when using these two functions.
Non Contact
Voltage
Indicator
Voltage Value
Battery Power
Indicator
Voltage Bar Graph
Indicator
Phase
Direction
High Voltage
Warning
DC Indication
AC Indication
DC Positive (+)
Polarity
DC Negative (-)
Polarity
g.3
g.4
g.5
g.6
g.7
Original Language Version
© Jack Sealey Limited PPHYIssue118/07/19

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycleunwantedmaterialsinsteadofdisposingofthemaswaste.Alltools,accessoriesandpackagingshouldbesorted,takento
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceableandrequiresdisposal,drainanyfluids(ifapplicable)intoapprovedcontainersanddisposeoftheproductandfluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty:Guaranteeis12monthsfrompurchasedate,proofofwhichisrequiredforanyclaim.
6. MAINTENANCE
6.1. BATTERY REPLACEMENT
WARNING! Disconnect the device from the voltage source and switch off when
replacing the batteries.
6.1.1. IfLCDashes5timesitwillswitchoffautomaticallyduringselfdiagnosticsorvoltage
measurement, this indicates the equipment has run out of battery. Please change the batteries.
6.1.2. BatterypowerlevelwillalsodisplayontheLCDduringthevoltagemeasurement;please
note the battery power level when using.
(1)Unlockthebatterycapbyusingacoin.
(2)Openthebatterycapandreplacethebattery.Beawareofthebatterypolarity(g.8).
(3)Putbackthebatterycapandlockitwithacoin.
WARNING! Please make sure the battery cap is locked before any operation.
6.2. CLEANING & STORAGE
9Use a light damp cloth with neutral detergent for cleaning the instrument. DO NOT use
abrasives or solvent.
8DO NOT expose the instrument to direct sun, high temperature, humidity or damp.
9 Removebatterieswhentheinstrumentisnotgoingtobeusedforalongperiod.
8DO NOT lock the battery cap without batteries. g.8
Original Language Version
© Jack Sealey Limited
BATTERY REMOVAL SEE SECTION 6.1
UndertheWasteBatteriesandAccumulatorsRegulations2009,JackSealeyLtdarerequiredtoinformpotentialpurchasersofproducts
containingbatteries(asdefinedwithintheseregulations).
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE).Whentheproductisnolongerrequired,itmustbedisposedofinanenvironmentallyprotectiveway.Contactyourlocalsolid
waste authority for recycling information.
PPHYIssue118/07/19
Table of contents
Other Sealey Test Equipment manuals

Sealey
Sealey CV0011.V3 User manual

Sealey
Sealey TA131 User manual

Sealey
Sealey VS0061 User manual

Sealey
Sealey VSE211.V4 Firmware update

Sealey
Sealey TA320 User manual

Sealey
Sealey pp6 User manual

Sealey
Sealey AUTO SERVICE LINE TA125 User manual

Sealey
Sealey VS0275 User manual

Sealey
Sealey TA319 User manual

Sealey
Sealey BT91/10 User manual

Sealey
Sealey BT2002.V2 User manual

Sealey
Sealey Auto Service Line VS2030 User manual

Sealey
Sealey BT91/7PF User manual

Sealey
Sealey VS926 User manual

Sealey
Sealey CT951.V4 User manual

Sealey
Sealey VS001.V3 User manual

Sealey
Sealey BT2014 User manual

Sealey
Sealey AUTO SERVICE BT91/7C User manual

Sealey
Sealey BT91/3 User manual

Sealey
Sealey TST22 User manual