Sealey GSA27 User manual

Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,
give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS,
WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH
IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE
THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
Follow workshop Health & Safety rules, regulations and conditions when using drill.
WARNING!Disconnect from air supply before changing accessories or servicing.
Maintain the drill in good condition and replace any damaged or worn parts. Use
genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
WARNING! Check correct air pressure is maintained and not exceeded. We recommended 90psi.
Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each
use and ensure that all connections are secure.
Wear approved safety gloves, eye and ear protection. If dust is generated wear respiratory
protection.
Keep drill bits clean and sharp for best and safest performance.
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
Secure unstable workpiece with a clamp, vice or other suitable holding device.
Ensure the chuck is securely fastened to the spindle and the drill bit is secure in the chuck.
Avoid unintentional starting.
Keep children and unauthorised persons away from the work area.
DO NOT hold the workpiece by hand. Use clamps or a vice to secure the workpiece.
DO NOT use the drill for a task it is not designed to perform.
WARNING! DO NOT use drill if damaged or thought to be faulty. Contact your local service agent.
DO NOT use drill unless you have been instructed in its use by a qualified person.
DO NOT drop, throw or abuse the drill.
DO NOT carry the drill by the air hose, or yank the hose from the air supply.
DO NOT operate drill if you are tired or under the influence of alcohol, drugs or intoxicating
medication.
DO NOT carry drill with your hand on the trigger in order to avoid unintentional starting.
DO NOT direct air from the air hose at yourself or others.
When not in use disconnect from air supply and store in a safe, dry, childproof location.
INSTRUCTIONS FOR:
13MM REVERSIBLE AIR DRILL
WITH KEYLESS CHUCK
MODEL No: GSA27
2. INTRODUCTION & SPECIFICATION
Chuck size:........................13mm
Free speed: ................600 to 700rpm
Air consumption:................... 4.5cfm
Operating pressure: ................. 90psi
Air inlet size:.....................1/4”BSP
Weight: ........................... 1.5kg
Noise Power: ..................99.71dB(A)
Noise Pressure: ................88.71dB(A)
Vibration Figure: ...................2.7m/s²
Uncertainty Value: ................0.46m/s²
Fully polished finish with exhaust through handle base for reduced noise emission. Unit features
encaged planetary gear drive assembly. Rotor runs on high quality ball bearings for long life and
reliability. Fully reversible drive with finger-tip control set above trigger. Fitted with Jacobs keyless
chuck for fast bit changes. Supplied with side handle. Contoured soft-grip handle gives added
comfort and control.
Original Language Version GSA27 Issue:3(SP)-31/07/13
© Jack Sealey Limited

3.1. Air Supply (Recommended hook-up is shown in fig. 1.)
3.1.1. Ensure drill air valve (or trigger) is in the "off" position before connecting to the air supply.
3.1.2. You will require an air pressure of 90psi and an air flow of 4.5cfm.
3.1.3. WARNING! Ensure the air supply is clean and does not exceed 90psi. Too high an air
pressure or unclean air will shorten the life of the drill due to excessive wear, and may
be dangerous, causing damage and/or personal injury.
3.1.4. Drain the air tank daily. Water in the air line will damage the drill.
3.1.5. Clean compressor air inlet filter weekly.
3.1.6. Line pressure should be increased to compensate for unusually long air hoses (over 8
metres). The minimum hose size should be 1/4” I.D. and fittings must have the same internal
bore.
3.1.7. Keep hose away from heat, oil and sharp edges. Check hose for wear and make certain
that all connections are secure.
3.2. Couplings
Vibration may cause failure if a quick change coupling is connected directly to the drill.
To overcome this, connect a leader hose to the drill. A quick change coupling may then be
used to connect the leader hose to the air line recoil hose. (See figs. 1 & 2).
3. PREPARING DRILL FOR USE
4. OPERATING INSTRUCTIONS
WARNING! Ensure you read, understand and apply safety instructions before use.
4.1. Take hold of the drill with one hand and wrap thumb and forfinger around the back part of
chuck. Spin front part of chuck anticlockwise with other hand to open the jaws to the size of
the drill bit to be used.
4.2. Insert drill bit and rotate front part of chuck until it starts to grip the drill bit. Grip rear part of
chuck and turn front part of chuck clockwise until the bit is firmly locked in place. Rotate
whole chuck to check that bit is running true.
fig.1
Original Language Version GSA27 Issue:3(SP)-31/07/13
fig.2
© Jack Sealey Limited

WARNING!Disconnect drill from air supply before changing accessories, servicing or
performing maintenance.Replace or repair damaged parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the warranty.
5.1. If the air system does not include an oiler, lubricate the drill daily with a few drops of Sealey
air tool oil dripped into the air inlet.
5.2. Clean the drill after use.
5.3. Loss of power or erratic action may be due to the following:
a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or
type of hose connectors. To remedy, check the air supply and follow instructions in
Section 3.
b) Grit or gum deposits in the drill. If your model has an air filter (located in the area of the
air inlet), remove and clean it. Flush the drill out with gum solvent oil or an equal mixture
of SAE No 10 oil and paraffin. Allow to dry before use.
5.4. For a full service contact your local Sealey service agent.
5.5. When not in use, disconnect from air supply, clean and store in a safe, dry, childproof
location.
4.3. Connect the drill to the air hose as in Section 3.
4.4. The drill direction is changed by switching the reverse lever behindthe trigger formside to
side. Check that the drill is set to operate in the required direction.
4.5. To adjust the position of the side handle loosen the sleeve directly above thegripwith an
18mm spanner. Rotate the grip to the position required and retighten.
4.6. Depress the trigger to operate the drill.
DO NOT allow drill to free run for an extended period of time as this will cause accelerated
wear.
5. MAINTENANCE
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
sales@sealey.co.uk
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
www.sealey.co.uk
Web
email
Original Language Version GSA27 Issue:3(SP)-31/07/13
© Jack Sealey Limited

WARNING! – Risk of Hand Arm Vibration Injury.
This tool may cause Hand Arm Vibration Syndrome if its use is not managed adequately.
This tool is to be operated in accordance with these instructions.
Measured vibration emission value (a): .................. 2.7m/s²
Uncertainty value (k):................................. 0.46m/s²
Please note that the application of the tool to a sole specialist task may produce a different average vibration emission.
We recommend that a specific evaluation of the vibration emission is conducted prior to commencing with a specialist task.
A health and safety assessment by the user (or employer) will need to be carried out to determine the suitable duration of use for
each tool.
NB: Stated Vibration Emission values are type-test values and are intended to be typical.
Whilst in use, the actual value will vary considerably from and depend on many factors.
Such factors include; the operator, the task and the inserted tool or consumable.
NB: ensure that the length of leader hoses is sufficient to allow unrestricted use, as this also helps to reduce vibration.
The state of maintenance of the tool itself is also an important factor, a poorly maintained tool will also increase the risk of Hand
Arm Vibration Syndrome.
PREPARING FOR USE.
Air Supply.
WARNING!
Ensure the air supply is clean and does not exceed 90psi while operating the tool.
Too high an air pressure and unclean air will shorten the product life due to excessive wear and may cause damage and/or
personal injury.
Ensure that the tool air valve (or trigger) is in the “off” position before connecting to the air supply.
Monitor the compressor daily to ensure that moisture is not present in the compressed air. Water in the air line will damage the tool.
Line pressure should be increased to compensate for unusually long air hoses (over 8metres).
The minimum hose diameter should be ¼” internal diameter. Fittings must have compatible inside dimensions.
Keep hoses away from heat, oil and sharp edges. Check hoses for wear and ensure that all connections are secure.
Couplings.
Vibration may cause failure if a quick change coupling is connected directly to the tool.
To overcome this, connect a leader hose to the tool (Sealey ref: AH2R or AH2R/38).
A quick change coupling may then be used to connect the leader hose to the air line recoil hose.
CORRECT USE.
Vibration emission is closely linked to the operating pressure in the air supply. The user should ensure that the pressure is set in
accordance with our recommendations to assure optimum efficiency and minimise vibration exposure.
• Ensurethatthetooliscorrectlyalignedtothework.Misalignmentincreasestheriskofvibrationinjury.
• Ensurethatconsumablesareselected,maintainedandreplacedinaccordancewithSealeyInstructions.
• Sleevefittingsmustbeusedwherepossible.
• Alwayssupportthetoolinastandoronabalanceroratensiondevicewherepossible.
• Ensurethattheoperatorissufficientlyexperiencedinordertobeabletohandleandoperatethetoolcorrectly.
• Ensurethatthetoolisheldwithalightbutsecuregrip.Avoidexcessivegripforceasthiswillincreasetheriskofvibrationinjury.
MAINTENANCE.
If the air system does not have an oiler, lubricate the air tool daily with a few drops of Sealey air tool oil dripped into the air inlet.
Clean the tool after use.
DO NOT use worn or damaged grinding discs (if applicable).
Loss of power or erratic action may be due to the following:
Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type of hose connectors. To remedy, check
the air supply and follow instructions in the PREPARING FOR USE section.
Grit, residual deposits (gum) in the tool may also reduce performance.
Remove the strainer. Clean the strainer and flush the tool out with gum solvent oil or an equal mixture of SAE No: 10 oil and
paraffin.
Allow the tool and strainer to dry then lubricate before use.
For a full service, contact your local Sealey service agent.
When not in use, disconnect the tool from the air supply, clean the tool and store the tool in a safe, childproof, location.
Health surveillance.
We recommend a programme of health surveillance to detect early symptoms of vibration injury so that management procedures
can be modified accordingly.
Personal protective equipment.
We are not aware of any personal protective equipment (PPE) that provides protection against vibration injury that may result from
the uncontrolled use of this tool. We recommend a sufficient supply of clothing (including gloves) to enable the operator to remain
warm and dry and maintain good blood circulation in fingers etc. Please note that the most effective protection is prevention, please
refer to the Correct Use and Maintenance section in these instructions.
Guidance relating to the management of hand arm vibration can be found on the HSC website www.hse.gov.uk - Hand-Arm
Vibration at Work.
Table of contents
Other Sealey Drill manuals

Sealey
Sealey Quality MACHINERY GDM250F User manual

Sealey
Sealey CP4001 User manual

Sealey
Sealey CP2024VHK User manual

Sealey
Sealey PDME160B User manual

Sealey
Sealey CP9918VHK User manual

Sealey
Sealey SA24.V3 User manual

Sealey
Sealey SA76 User manual

Sealey
Sealey SUPER TORQUE CP3014vHK User manual

Sealey
Sealey SDSPLUS32 User manual

Sealey
Sealey CP3018VHK User manual

Sealey
Sealey SA1008 User manual

Sealey
Sealey SNA9821 User manual

Sealey
Sealey GDM150B/VS User manual

Sealey
Sealey MAG110V User manual

Sealey
Sealey Power Tools SA621.V2 User manual

Sealey
Sealey SA24.v2 User manual

Sealey
Sealey SA23/S.V3 User manual

Sealey
Sealey SV10.8 Series User manual

Sealey
Sealey SDM150 User manual

Sealey
Sealey GDM50B.V2 User manual