schildknecht DATAEAGLE COMPACT 4 Series Guide

Installation and commissioning manual
Wireless Data System
DATAEAGLE® 4XXX Compact
Schildknecht AG
D -71711 Murr –Haugweg 26
Tel +49 (0)7144 89718-0 - Fax +49 (0) 7144 8971829
Email: office@schildknecht.ag - Internet: www.schildknecht.ag
DATAEAGLE 4XXX Compact
Version: 14.04.2020

Montage und Inbetriebnahme DATAEAGLE 4XXX Compact
© Copyright
Schildknecht AG
All rights reserved.
No part of this publication
may be reproduced or
translated in full or in part
without prior written per-
mission.
Right to make changes
Changes may be made
at any time to the form,
equipment and technol-
ogy of items covered in
this documentation. For
this reason, no claims re-
lating to the aforemen-
tioned may be derived
from the information,
illustration and descrip-
tions provided in these
operating instructions for
appliances or systems
manufactured after the
date of issue of these op-
erating instructions.
Warranty
Schildknecht AG can ac-
cept no liability for indi-
rect damage or direct
damage, incidental dam-
age, consequential dam-
age or compensation for
expenses incurred by
performance of contract
which arise from deliv-
ery, provision and use of
this material.
Introduction

Montage und Inbetriebnahme DATAEAGLE 4XXX Compact
To start with, we have a few important things to say about
safety. Please observe these instructions without fail, in order
to avoid property damage and personal injury.
We show you step by step how to install the system, put it
into operation and how to operate it.
Any questions? First, have a look in the table of contents.
You will quickly find what you are looking for.
If you do need us in person: just call us or send a fax:
Schildknecht AG
Haugweg 26
D -71711 Murr
Phone
+49 / (0) 7144 89718-0
Fax
+49 / (0) 7144 8971829
Internet
www.schildknecht.ag
e-mail
WWW
e-mail
FAX

Montage und Inbetriebnahme DATAEAGLE 4XXX Compact
List of contents
Subject Page no.
Introduction 1-1
1. General information 1-1
1.1. Guide to symbols 1-1
1.2. Copyright and brand names 1-1
1.3. Declaration of conformity and EC directives 1-1
2. Safety instructions 2-1
2.1. Intended use 2-1
2.2. General information 2-1
2.3. Installations instructions 2-2
2.4. Safety instructions for operation 2-2
2.5. Personnel qualification 2-3
3. Structure 3-1
3.1. System description 3-1
3.2. Radio module 3-2
4. Installation of new devices 4-1
4.1. Overview Installation 4-1
4.2. Install unit on top-hat rail 4-2
4.3. Install antenna cable 4-3
4.4. Connect Ethernet plug 4-4
4.5. Connect power supply 4-4
5. Extension and exchange 5-1
5.1. Preparation 5-1
5.1.1. System requirements 5-1
5.1.2. Create a new folder 5-1
5.1.3. Microsoft Internet Explorer 5-2
5.1.4. Install USB drivers 5-3
5.1.5. Install Dataeagle Wizard 5-7
5.2. Extension 5-9
5.2.1. Additional Profinet device / Safety Node (SN) to existing or new
Radio Slave 5-9
5.2.2. Additional Radio Slave 5-9
5.2.3. Start Dataeagle Wizard 5-10
5.2.4. Configure Radio Master 5-11
5.2.5. Configure Radio Slave 5-16
5.3. Exchange 5-19
5.3.1. Remove wiring 5-20

Montage und Inbetriebnahme DATAEAGLE 4XXX Compact
5.3.2. Remove old module 5-20
5.3.3. Install new module 5-20
5.3.4. Start Dataeagle Wizard 5-21
5.3.5. Procedure for exchanging radio modules 5-22
5.3.6. Example 1: Exchange of a Radio Slave 5-23
5.3.7. Example 2: Exchange of a radio master 5-30
6. Increasing the system availability (Profinet only) 6-1
6.1. Function 6-1
6.2. Setting of the filter time at Radio Master and Radio Slave 6-1
6.3. Typical values for the filter time 6-5
6.3.1. Default 6-5
6.3.2. Recommendation for operation 6-5
6.3.3. Recommendation for commissioning 6-5
6.3.4. Recommendation for applications with Profisafe 6-5
7. Dismantling and disposal 7-1
8. Tips and Tricks 8-1
8.1. Improving the EMC safety 8-1
8.1.1. Introduction 8-1
8.1.2. Basic guidelines 8-1
8.2. Guidelines for optimized installation of antennas 8-5
8.3. Advices for troubleshooting 8-7
9. Technical specifications 9-1

Installation and commissioning DATAEAGLE 4XXX Compact 1-1
Chapter 1 –General information
1. General information
1.1. Guide to symbols
This section contains an explanation of the symbols used in
this manual.
Indicates an imminently hazardous situation which, if not
avoided, may result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, may result in property damage.
Indicates sections which contain important information.
Indicates work operations which need to be carried out.
This symbol is followed by a description about how the status
of the system changes after an operation has been carried
out.
1.2. Copyright and brand names
Brand names and product names mentioned in this manual
are trademarks or registered trademarks of their respective
owners.
Microsoft Windows 7, Windows Vista, Windows 2000, Win-
dows XP and Microsoft Internet Explorer are registered
trademarks of Microsoft Corp.
Adobe Reader is a registered trademark of Adobe Systems
Corp.
DATAEAGLE® is a registered trademark of Schildknecht AG.
1.3. Declaration of conformity and EC
directives
Information about the declaration of conformity and about EC
directives can be found under:
http://www.schildknecht.ag/download/dataeagle-konformitaetserklaerung
CAUTION

Installation and commissioning DATAEAGLE 4XXX Compact 2-1
Chapter 2 - Safety instructions
2. Safety instructions
2.1. Intended use
Information about the intended use can be found in the oper-
ating instructions wireless data systems DATAEAGLE.
2.2. General information
In order to guarantee safe use and fault-free operation, the
according safety instructions have to be observed under all
circumstances.
Safety instructions which apply to all product families are de-
scribed in the operating instructions for wireless data sys-
tems DATAEAGLE. This manual is part of the system docu-
mentation. Read these instructions before installation and
commissioning of the wireless data system.
Safety instructions which apply only to an individual wireless
data system are described below and in the according sec-
tion of this installation and commissioning manual.

Installation and commissioning DATAEAGLE 4XXX Compact 2-2
Chapter 2 - Safety instructions
2.3. Installations instructions
Country licenses can be found in the attached declara-
tion of conformity.
Risk of electrical shock.
Always disconnect the modules from the power source
when working on the modules (installation, etc.)!
Risk of injury.
Comply with the local regulations and safety instruc-
tions during installation!
Static charges can damage electronic devices.
Remove electrostatic discharge from your body before
touching the device!
The modules must not be opened or modified (except
the steps described in this manual). Do not repair the
module yourself, replace it with an equivalent module.
Repairs may only be carried out by the Schildknecht AG.
The Schildknecht AG is not liable for damage resulting
from a failure to comply.
2.4. Safety instructions for operation
Electromagnetic radiation.
Keep at least a distance of 20 cm to the antennas when
the devices are in operation.
CAUTION
CAUTION

Installation and commissioning DATAEAGLE 4XXX Compact 2-3
Chapter 2 - Safety instructions
2.5. Personnel qualification
Only qualified personnel may carry out the following tasks:
Installation
Commissioning
Operation
Maintenance
Within the context of safety regulations, qualified personnel
are individuals authorized to commission, to ground, and to
identify equipment and systems in accordance with the
safety-engineering standards.
All operating personnel must be trained accordingly.
Personnel involved with operating the unit in conjunction with
controllers must possess sound programming skills for the in-
dividual controller and programming language in question.

Installation and commissioning DATAEAGLE 4XXX Compact 3-1
Chapter 3 –Structure
3. Structure
3.1. System description
The system DATAEAGLE 4xxx is used for a transparent
Ethernet data transmission. It consists of a radio master and
up to 4 radio slaves (depending on the device type).
The series DATAEAGLE 4xx2, 4xx3 and 4xx5 is optimized
for Profinet and openSAFETY via UDP.
Up to 6 Profinet devices or 16 Safety Nodes (SN) can be
connected to one or more radio slaves (depending on the de-
vice type).
The radio links work like an Ethernet cable.
Each radio module is identified by its address.
Subsequently the terms Ethernet and Profinet are used
equivalently. Differences are described where appropriate.
This manual suits for next models
8
Table of contents
Other schildknecht Microphone System manuals
Popular Microphone System manuals by other brands

Sennheiser
Sennheiser Evolution Wireless Digital EW-DX EM 2 quick guide

Alpha Technologies
Alpha Technologies RBMS Installation & operation manual

SWIT Electronics Co.,LTD.
SWIT Electronics Co.,LTD. CW-S150 user manual

Shure
Shure UA844 user guide

Panasonic
Panasonic SHFX70 - DVD HOME THEATER WIRELESS SYSTEM operating instructions

Pyle
Pyle PDWM5000 user manual