Krog Iversen & Co. A/S - DK-5492 Vissenbjerg
Technical info
Rated output: 6 kW
Min./max.: 2 - 8 kW
Weight of radiation stove: 70 kg
Weight of convection stove: 92 kg
Connection piece diameter: int. 120 mm/ext. 128 mm
Warranty conditions
All SCAN wood-burning stoves and inserts are made of first-class material and are subject to a strict quality control,
before they leave the factory. However, if an error should occur, we back all SCAN wood-burning stoves and inserts with
an extensive, five-year limited warranty.
See also the General Instructions for Installation delivered with your stove for more details.
Distances to flammable
materials (mm)
710
385 570
126
SCAN Andersen 1
Data for calculation of the chimney
Stove with convection
You should observe the following mini-
mum distances from the sides of the
stove:
D
C
D
Floor
plate
500
300
Radiation area
Corner
Wall
B
A
C
500
Radiation area
Floor
plate
For radiation stoves, the distance to the side
walls is as follows:
CORNER: 300 mm
WALL: 450 mm
Stove
model
SCAN
Connecting
adaptor
mm
1
Density of
flue gas
flow
g/s
2
Flue gas
tempera-
ture
oC
3
Minimum
draft
Pa
4
Density of
flue gas
flow
g/s
5
Flue gas
temperature
oC
6
Minimum
draft
Pa
7
0,8
Minimum
draft
Pa
A1 130 - - - 7,3 270 13 11
With closed doorsWith open doors
Column 5 shows the flue gas temperature in the connecting adaptor
Column 6 shows the lowest/minimum draft in Pa by rated value
Column 7 shows the lowest/minimum draft in Pa by 0.8 x rated value