Samsung SSA-S2000W User manual

Standalone RFID
Access Controller
user manual
SSA-S2000
imagine the possibilities
Thank you for purchasing this Samsung product.
To receive more complete service,
please visit our website.
www.samsungsecurity.com

2_ Safety information
safety information
CAUTION
RISK OF ELECTRIC SHOCK.
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
This symbol indicates that dangerous voltage consisting a risk of electric shock is
present within this unit.
This exclamation point symbol is intended to alert the user to the presence of
important operating and maintenance (servicing) instructions in the literature
accompanying the appliance.
WARNING
To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture.
WARNING
Be sure to use only the standard adapter that is specified in the specification sheet.
Using any other adapter could cause fire, electrical shock, or damage to the product.
Incorrectly connecting the power supply or replacing battery may cause explosion, fire, electric shock, or damage to
the product.
Do not connect multiple controllers to a single adapter. Exceeding the capacity may cause abnormal heat generation or fire.
Securely plug the power cord into the power receptacle. Insecure connection may cause fire.
When installing the controller, fasten it securely and firmly. The fall of controller may cause personal injury.
Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or containers filled with water on top of the
controller. Doing so may cause personal injury due to fire, electric shock, or falling objects.
Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fire or electric shock.
If any unusual smells or smoke come from the unit, stop using the product. In such case, immediately disconnect the
power source and contact the service center. Continued use in such a condition may cause fire or electric shock.
If this product fails to operate normally, contact the nearest service center. Never disassemble or modify this product in
any way. (SAMSUNG is not liable for problems caused by unauthorized modifications or attempted repair.)
. When cleaning, do not spray water directly onto parts of the product. Doing so may cause fire or electric shock.
CAUTION
Do not drop objects on the product or apply strong blows to it. Keep away from a location subject to excessive
vibration or magnetic interference.
Do not install in a location subject to high temperature (over 50°C), low temperature (below -10°C), or high humidity.
Doing so may cause fire or electric shock.
If you want to relocate the already installed product, be sure to turn off the power and then move or reinstall it.
Remove the power plug from the outlet when there is a lighting storm. Neglecting to do so may cause fire or damage
to the product.
•
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
1.
2.
3.
4.

English _ 3
SAFETY INFORMATION
Keep out of direct sunlight and heat radiation sources. It may cause fire.
Install it in a place with good ventilation.
Avoid aiming the controller directly towards extremely bright objects such as sun.
Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be
placed on the apparatus.
The Mains plug is used as a disconnect device and shall stay readily operable at any time.
FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions :
This device may not cause harmful interference, and
This device must accept any interference received including interference that may cause undesired operation.
5.
6.
7.
8.
9.
1)
2)
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with dry cloth.
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
Do not install near any heat sources such as radiators, heat registers, or other apparatus (including amplifiers) that
produce heat.
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one
wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third
prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the
point where they exit from the apparatus.
Only use attachments/accessories specified by the manufacturer.
Use only with cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with
the apparatus.
Unplug this apparatus when a card is used. Use caution when moving the cart/ apparatus
combination to avoid injury from tip-over.
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any
way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus,
the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
IMPORTANT SAFETY INSTRUCTIONS
Caution
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part
15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in ac-
cordance with the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.

4_ Contents
contents
PRODUCT INTRODUCTION
6
6Features
7What’s included
8At a Glance
9Cable Color Scheme
INSTALLATION AND EXTERNAL
CONNECTION
10
10 Installing the rear template
11 Cable Selection
12 Bypass Diode Connection
12 I/O Connection
14 External Reader Connection
INITIALIZATION
15
15 Basic Operations
16 Wiegand Output Setup
16 Initialization
17 Forced Initialization with External Line
17 Hardware Forcible Initialization
READER MODE SETUP
18
18 Reader Mode Setup (RF ONLY)
19 Reader Mode Setup (RF + P/W)
19 Reader Mode Setup (PIN ONLY)
20 Reader Mode Setup (RF/PIN Combination
Mode)
20 Enabling Keypad Input for the Card Number
USER MANAGEMENT
21
21 To register cards in RF ONLY mode
21 RegIsterIng cards In a combInatIon oF RF
and P/W modes
22 to regIster cards In PIn mode
22 regIsterIng cards In rF card / PIn combInatIon
mode
23 to delete a regIstered card or PIn number
BASIC SETUP
24
24 Duress Alarm
24 To specify the retry count for an unregistered
ID
25 To specify the keypad input suspension time
if the retry count with an unregistered ID
exceeds the limit
25 To specify the delayed start time in Secure
mode
26 To specify the operation time of the Door
Contact Sensor
26 To specify the limited time for the keypad
input
27 To specify the alarm output port for the
dismantled device
27 To open or close the entry door
28 To set or release the QUICK mode
28 To set or release the Toggle mode for the
door relay
29 To specify the output time if the card is
authenticated

English _ 5
CONTENTS
ADVANCED SETTING
34
34 To specify the TTL output operation mode
34 To set the chime bell function
35 To specify the chime bell operation time
35 To specify the input mode for AUX 1
36 To specify the input mode for AUX 2
36 To specify the input mode for AUX 3
37 To specify the input mode for the Exit Button
37 To specify the input mode for the Door
Contact Sensor
38 Mute
38 To specify the use of the tamper alarm
ADDITIONAL FEATURES
38
39 To check the output specified for a registered
card user
39 To check the output specified for an
unregistered card user
40 To check the output specified for the Door
Contact Sensor alarm
40 To check the output specified for AUX 1
41 To check the output specified for AUX 2
41 To check the output specified for AUX 3
I/O TIME SETUP
29
30 To specify the output time if the card is not
authenticated
30 To specify the Duress TTL output
31 To specify the alarm output for an input error
of the Door contact Sensor
31 To specify the alarm operation time for AUX 1
32 To specify the alarm operation time for AUX 2
32 To specify the alarm operation time for AUX 3
33 To activate or deactivate the door relay by
the Door Contact Sensor
OTHER INFORMATION
42
42 InItIal Values
43 FunctIon codes
TROUBLESHOOTING
45
45 Troubleshooting
PRODUCT SPECIFICATIONS
50
50 product specifications

6_ Product Introduction
FEATURES
This controller is best designed for a single entry door control (single door access control).
It can store up to 512 cards including the Master Card that enables you to register, delete or set various user cards to
your preference.
This product features 5 external ports that can be connected to the Exit button, Door Contact Sensor, Motion Sensor,
and Fire Sensor. It also has 2 relay outputs that can control the door lock and alarm relay. The dual tamper switch triggers
an alert if the product is forcibly disassembled.
You can use the keypad to configure all settings as necessary.
This product is designed for a standalone system.
Single Door Access Control
You can use the RF card (SSA-C100,SSA-C110,SSA-C120) to control a single door.
User Registration
You can register a total of 512 cards including the Master Card.
Keypad Registration
SSA-S2000 is equipped with the built-in keypad that you can use to register, delete cards or configure various settings
independently.
Buzzer On/Off
With the help of various buzzer tones, you can check the operation status and the current settings and results of the
product.
External I/O Pins
SSA-SS2000 has 5 input ports and 4 output ports installed (2 relay and 2 TTL outputs).
The input ports can receive signals from the Exit button and the Door Contact sensor, while the two relays can be
connected to the door lock and the alarm device. One of the TTL output ports can function as a chime bell in connection
with the door bell.
Duress Alarm
This is used in a situation where you should open the door inevitably by a robber insisting to do so. Entering the two-digit
duress alarm password with pressing the
ENT
button and recognizing the registered card (or card number)
can open the door normally, while you can set to produce the TTL signal notifying the door is forcibly
opened.
Limited Access Tries for an Unregistered Card
You can specify the limit of times to try accessing the door, and the suspended operation time of the keypad for an
improper access.
product introduction

English _ 7
PRODUCT INTRODUCTION
WHAT’S INCLUDED
Check if the following items are included in the product package.
X Y Z
[ \ ]
^ _ `
lzj lu{
W
i
zzhTzYWWW
Main Unit Template O-rings (x5)
xGn
3.5 x 40mm Screws (x4)
3.5 x 12mm Screws (x4)
6 x 30mm Plastic Anchors (x4)
Quick Guide Diodes (x2)
(UF4004, 1N4001~4007)
tGj
Master Card (x1) Cables (x4) CD Manual

8_ Product Introduction
product introduction
AT A GLANCE
Front View
System Status LED
Indicates the operation status of the system.
Keypad
Use this to configure or release settings as appropriate, or enter a card
number.
X Y Z
[ \ ]
^ _ `
lzj lu{
W
i
zzhTzYWWW

English _ 9
PRODUCT INTRODUCTION
CABLE COLOR SCHEME
2-PIN Connector
I/O Pins Signal Cable Color
Power (+12V) DC +12V Red
Earth-grounding GND(-) Black
10-PIN Connector
I/O Pins Signal Cable Color
Door Control Relay (NC) NC(RL1) Blue with White stripes
Door Control Relay (COM) COM(RL1) Gray with Red stripes
Door Control Relay (NO) NO(RL1) White with Red stripes
Alarm Relay (NC) NC(RL2) Purple with White stripes
Alarm Relay (COM) COM(RL2) White
Alarm Relay (NO) NO(RL2) Purple
Exit Button EXIT Orange
Door Contact Sensor CONTACT Yellow with Red stripes
Aux Input #1 AUX IN 1 Green
Aux Input #2 AUX IN 2 Green with White stripes
7-PIN Connector
I/O Pins Signal Cable Color
Wiegand Data Input 0 DATA_0 Pink
Wiegand Data Input 1 DATA_1 Sky blue
TTL Output TTL Orange with White stripes
Chime Bell Output CHI Brown with White stripes
Aux Input #3 AUX IN 3 Green with Red stripes
RESERVED 1 Blue with Red stripes
RESERVED 2 Yellow with Red stripes
3-PIN Connector
I/O Pins Signal Cable Color
RESERVED 1 Black with White stripes
RESERVED 2 Red with White stripes
RESERVED 3 Black
❖
❖
❖
❖

10_ Installation and External Connection
installation and external connection
INSTALLING THE REAR TEMPLATE
Once the main unit is fixed with the rear panel, it will not be loosened. Please check if the device is operating before fixing
it. If you try to remove the rear panel once it is fixed, the lock parts of the rear panel will break, resulting in a situation
where the whole rear panel must be replaced.
J
2.05"(52mm) 1.85"(47mm)
3.03"(77mm)
1.52"(38.5mm) 1.52"(38.5mm)
1.55"(39.5mm)1.79"(45.5mm)
O-ring
O-ring
O-ring
O-ring
O-ring
6-32 hole
6-32 hole
1/2” hole
This manual suits for next models
1
Table of contents
Other Samsung IP Access Controllers manuals

Samsung
Samsung SSA-S2100 User manual

Samsung
Samsung SSA-R2010 User manual

Samsung
Samsung SSA-S1000 User manual

Samsung
Samsung SSA-S1000V User manual

Samsung
Samsung SSA-P400 User manual

Samsung
Samsung SSA-S2000V User manual

Samsung
Samsung SSA-R1001 User manual

Samsung
Samsung SSA-R1000V User manual

Samsung
Samsung Techwin SSA-R1001V User manual

















