CT1000 v2
CT1000 v2 is a touch keypad that can be installed and used for
many different purposes, e.g. to open a door, turn on the light, or
call for an elevator - just a few among many other options.
Art.no. 460100 - CT1000v2 Black
Art.no. 460106 - CT1000v2 White.
www.conlan.eu

USER MANUAL - CT1000 v2-ENG-04-23
CONTENT
1. INSTALLATION Page 3
2. ACCESS Page 3
2.1. Using the device Page 3
3. FIXED USER PIN CODES MANAGEMENT Page 4
3.1 Add user PIN codes Page 5
3.2 Delete user codes Page 5
4. CONFIGURATION Page 6
4.1 Software Factory Reset Page 6
4.2 Delete All User PIN Codes Page 7
4.3 Change User Configuration Code Page 7
4.4 Change Service Configuration Code Page 8
4.5 Light indications Page 8
4.5.1 Idle State Indication Page 9
4.5.2 Output2 Active State Indication Page 9
4.5.3 Wrong PIN Inserted Indication Page 9
4.5.4 Back Lights Configuration Page 10
4.6 Outputs Configuration Page 11
4.7 Feedback Page 13
4.8 Special Functions Page 15
4.9 Splitter and Bell Function Page 16
4.10 Custom User Output Page 18
5. HARDWARE FACTORY RESET Page 19
6. REX INPUT Page 20
7. TECHNICAL SPECIFICATIONS Page 20

3
USER MANUAL - CT1000 v2-ENG-04-23
USER MANUAL -CT1000 v2-ENG-04-23
2.1. Using the device
The CT1000 v2 can store up to 200 xed PIN codes that range from 1 to 8 digits long. Each user
is allocated their own PIN code to operate the lock, which also enables sharing one lock between
different users.
The default xed PIN code ‘1234’ is pre-congured at position 1 during fabrication and can be
used to test the device.
To manage the xed user PIN codes, please refer to section 3, ‘Fixed User PIN Codes Manage-
ment’, on page 4.
2. ACCESS
The keypad is a standalone device that allows access to open a lock by entering a custom user
PIN code.
1. INSTALLATION
To learn how to install the keypad, please refer to the installation guide.
When a valid user PIN code is inserted, a
conrmation beep will sound, and the green
LED will light as long as
Output2 is activated (default 5 seconds).
#
32 4
1
Example:
Opening and Closing
When the device is idle, the yellow light (factory
default) is always ON, and the keypad is waiting
for user interaction.
The back-lights are OFF by default but turn on
when a key is touched.
Idle State

4
USER MANUAL - CT1000 v2-ENG-04-23
The next sections uses Juan as example to add and delete xed PIN codes on the device.
Position User PIN
1 Carlos 148954
17 Torbjörn 94830132
23 Juan 1111
Example of user tracking:
Example:
3. FIXED USER PIN CODES MANAGEMENT
Each user code is stored in a specic address of internal memory (from 1 to 200). We recommend
keeping a record of the position number and user names for future management.
To add or delete user codes, you need to access the User Conguration Menu by entering the User
Conguration Code (factory default is 4711) followed by ‘#’.
If four successive wrong attempts are made, the keypad will lock out for 60 seconds.
1#
7 1
4
The green LED will blink, indicating that
the keypad is ready to add or delete xed
user PIN codes.
User Conguration Menu
Enter:
When a wrong code is entered, a re-
jection beep will sound, and the red
LED will blink three times.
#
00 0
0
Example:
Wrong Code

5
USER MANUAL - CT1000 v2-ENG-04-23
USER MANUAL -CT1000 v2-ENG-04-23
3.2 Delete user codes
To delete one or more xed PIN codes, you don’t need to know the specic code, but you must
know its position.
3.1 Add user PIN codes
If a valid position is entered, a conrmation beep will sound, then
the keypad go back to User Conguration Menu and is ready to
perform another user PIN handling action.
#
3
2
Example:
The red LED will blink rapidly. Then insert the position of the PIN
code that you want to delete and press ‘#’ to conrm the deletion.
(a number between 1 and 200).
#2
Insert:
Deleting a specic PIN code
It’s important to note that all positions can be overwritten, which
means that you should keep a record of all congured PIN codes
and their corresponding positions. This will help you avoid acciden-
tally deleting or modifying any existing PIN codes.
1#
1 1
1
Example:
When a valid position is entered, the yellow LED will blink slowly
while the green LED will blink rapidly until a new user PIN code is
inserted. It’s important to note that the new user PIN must consist of
a numeric sequence that ranges from 1 to 8 digits.
#
3
2
The yellow LED will blink rapidly. Then insert a user position be-
tween 1 and 200 to place the new PIN code.
Example:
#1
Insert:

6
USER MANUAL - CT1000 v2-ENG-04-23
4. CONFIGURATION
To congure the CT1000 v2, you need to access the Service Conguration Menu with the Service
Conguration Code (12347890 as factory default). This code is used to authenticate and access the
menu.
You can access this menu within the first 5 minutes after the device has been powered up,
after which it becomes inaccessible.
Once in Service Conguration Menu, the following actions can be performed:
4.1 Software Factory Reset
If you need to reset the device to its factory default settings, please follow these steps:
Within the first 5 minutes after the device has been powered up
The green LED will blink, indicating that the keypad is ready to be con-
gured.
9#
8 0
7
32 4
1
Insert:
5#
2 0
0
A conrmation beep will sound and all indication LEDs will
light up for a few seconds. Then, the device will automatically
restart and return to the idle state.
Insert:

7
USER MANUAL - CT1000 v2-ENG-04-23
USER MANUAL -CT1000 v2-ENG-04-23
To clear all stored user PIN codes from the device’s memory, please follow these steps:
4.3 Change User Configuration Code
4.2 Delete All User PIN Codes
2#
3 1
4
The User Conguration Code has been changed. The keypad
will go back to Service Conguration Menu and is ready to
perform another Service Conguration action.
The red LED will blink slowly. Insert a new User Congura-
tion Code between 4 to 8 digits
Example:
Insert: 1 #
A conrmation beep will sound to indicate that all the stored
PIN codes have been deleted.
0#
5 0
2
Insert:
The keypad will return to the Service Conguration Menu and
will be ready to perform another action.

8
USER MANUAL - CT1000 v2-ENG-04-23
4.4 Change Service Configuration Code
The light indications for different device states can be customized as follows:
4.5 Light indications
Example:
Example:
The Service Conguration Code has been changed. The keypad go
back to Service Conguration Menu and is ready to perform another
Service Conguration action.
9#
8 0
7
32 4
1
The green LED will blink slowly while the yellow LED will blink rapidly
until the new Service Conguration Code is inserted again to conrm
the action. Insert the same code again.
9#
8 0
7
32 4
1
The green LED will blink slowly. The keypad is ready to receive a new
Service Conguration Code. Insert a code that is between 4 to 8 digits.
Insert: 2 #
The green and red LEDs will blink slowly.
To access the LED conguration menu:
Insert: 3 #

9
USER MANUAL - CT1000 v2-ENG-04-23
USER MANUAL -CT1000 v2-ENG-04-23
4.5.1 Idle State Indication
4.5.2 Output2 Active State Indication
4.5.3 Wrong PIN Inserted Indication
Is the device normal state, it remains idle until a user action is performed.
This will show when OUTPTU2 is active (regardless of whether it’s oating or GND as output signal)
by a right user PIN code inserted or a REX input triggered for example.
To customize these three congurations, the desired LED can be turned ON or OFF by pushing 1 to
toggle the yellow LED, 2 to toggle the green LED, and 3 to toggle the red LED. Once the indication
is as desired, push # to save it.
The device shows the current Idle State indication. The yel-
low LED ON as default.
Insert: 1 #
The device shows the current OUTPTU2 Active State indica-
tion. The yellow and green LED’s ON as default.
Insert: 2 #
The device shows the current Wring PIN Inserted indication.
The red LED ON as default.
Insert: 3 #
#
Insert: To save the changes. After each customization,
the device returns to the Light Indications menu,
and another conguration can be performed.
LED’s
Values to toggle the LED’s:
Yellow Green Red
1 2 3

10
USER MANUAL - CT1000 v2-ENG-04-23
4.5.4 Back Lights Configuration
The device turns OFF all indication LED’s and shows the cur-
rent Back Lights State.
As default the Back Lights are turned ON for 5 seconds when
a key is touched, after what the lights turns OFF again. This
state is indicated by a slow blink of the Back Lights.
Insert: 4 #
To toggle the back lights state.Insert: 4
Three states are allowed:
• Always ON
• Always OFF
• Turn ON for 5 seconds when a key is touched
(indicated by a slow blink of the Back Lights).
#
Insert: To save the changes. After each customization,
the device returns to the Light Indications menu,
and another conguration can be performed.
Other manuals for Conlan CT1000 v2
1
This manual suits for next models
2
Table of contents
Other Salto Door Opening System manuals
Popular Door Opening System manuals by other brands

Normstahl
Normstahl IDO7 installation manual

Häfele
Häfele Finetta T 70 VF manual

AGS
AGS D-PL Instructions for fitting, operating and maintenance

Stanley
Stanley MA900ñ Installation and owner's manual

WITTUR
WITTUR Hydra Plus UD300 Instruction handbook

Alutech
Alutech TR-3019-230E-ICU Assembly and operation manual