Roto E-Tec Series User manual

Roto E-Tec
Electronic drive and control systems
for windows and doors
Installation instructions for detachable miniature cable junctions

Imprint
Copyright: July 2012
Roto Frank AG
Wilhelm-Frank-Platz 1
D-70771 Leinfelden-Echterdingen
Telephone: +49 711 7598 0
Telefax: +49 711 7598 253
www.roto-frank.com
Liability exclusion
All specifications in this brochure were
diligently compiled and validated.
Changes due to technical progress,
changes in legislation and the passage
of time are unavoidable. We therefore
hope you understand that we cannot
be held liable for the accuracy or
completeness of the contents.
All rights, in particular the right to copy
and circulate, reserved.

Subject to change. Roto E-Tec Cable junctions IMO_229_EN_v0.July 2012
.3
Information on the product
Detachable miniature cable junction .......................... 4
Technical specifications .......................................................5
Detachable miniature cable junction
with alarm-glass connection socket........................... 6
Technical specifications .......................................................7
Scope of delivery ....................................................... 8
Dimensions ................................................................ 9
Mounting
Advice...................................................................... 10
Preparation for mounting......................................... 11
Cable junction .......................................................... 12
Determining connection assignment........................ 14
Detachable miniature cable junction
with alarm-glass connection socket ...................................14
Dismantling.............................................................. 15
Accessories
Cover plates, mounting box ..................................... 16
Dimensions & delivery scope .............................................17
Installation drawings for cover plates ...................... 18
Installation drawings for mounting box ................... 19
Contents

4
.July 2012
.IMO_229_EN_v0 Roto E-Tec Cable junctions Subject to change.
6-pin, detachable connector
Moulded-on cable
Window rebate installation
Due to its compact dimensions, the model M1334
cable junction(619 586) can be installed concealed
in the window and balcony door rebate without
additional milling.
After loosening the locking screw and disconnecting
the integrated, 6-pin connector
, the window/door can
be removed.
The cable is moulded onto the cable
junction pieces on the socket and plug side.
Information on the product
Detachable miniature cable junction

Subject to change. Roto E-Tec Cable junctions IMO_229_EN_v0.July 2012
.5
Technical specifications
Cable LiF9Y11Y 6-pin version 4.9mm dia., grey
6 wires: 0.34mm2, red, blue, white, brown, green and yellow
Max. 3.0A current load
Cable length on socket side 4m
Cable length on plug side 6 m
Protection type in accordance with DIN40050 IP67 (when plugged in)
Max. voltage 48VDC
Temperature range when moving -5°C to + 50°C
at rest -25°C to + 70°C
Fig.: Block diagram of socket
Fig.: Block diagram of plug
LIYY 6 x 0.34mm2
LIYY 6 x 0.34mm2
Information on the product
Detachable miniature cable junction
Technical specifications

6
.July 2012
.IMO_229_EN_v0 Roto E-Tec Cable junctions Subject to change.
Detachable connector
Suitable for alarm glass
Protection class IP67
The model M 13 40(619 587) detachable cable
junction is used to cover the transition from supply
lines in the window or balcony door rebate. The
simple disconnection of the cable junction via the
connector in the rebate area enables the sash to be
removed.
The minimal space requirement permits installation
at many points in the rebate area. With the window
closed, concealed installation in the window rebate
prevents access to the cable junction.
And the integrated tamper circuit (opening
monitoring ) enables monitoring of the plugged-in
connection. Opening of the connector is signalled by
the alarm control panel. In addition, the connector is
also mechanically fixed in place with a screw. With
the alarm-glass connection socket (AGV) at the other
end of the cable of the cable junction, alarm glasses
can be connected directly to the cable junction.
Information on the product
Detachable miniature cable junction with alarm-glass connection socket

Subject to change. Roto E-Tec Cable junctions IMO_229_EN_v0.July 2012
.7
Technical specifications
Cable plug LiF9Y11Y 6 x 0.14mm2 4.9mm dia., white
Cable socket LiY11Y 4 x 0.14mm2 3.2mm dia., white
Cable length on socket side, outside of spiral 0.33m
Cable length on plug side 6 m
Protection type in accordance with DIN40050 IP67 (when plugged in)
Max. voltage 48VDC
Max. current 0.5A
Temperature range when moving -5°C to + 50°C
at rest -25°C to + 70°C
Environmental grade in accordance with VdS2110
III
VdS approval number G108094
Information on the product
Detachable miniature cable junction with alarm-glass connection socket
Technical specifications

8
.July 2012
.IMO_229_EN_v0 Roto E-Tec Cable junctions Subject to change.
Delivery scope of model M 1334 detachable
miniature cable junction (mat. no. 619 586)
6-pin plug unit in PVC housing moulded with
connection cable
6-pin socket unit in PVC housing moulded with
assembled VA metal spring and connection cable
End piece for installation of the VA metal spring
4 each A2 fastening screws, DIN7982
(2.9 x 19mm)
Installation instructions
Delivery scope of detachable miniature cable
junction with alarm-glass connector
Model M 1340 (mat. no. 619 587)
6-pin plug unit in PVC housing moulded with
connection cable
6-pin socket unit in PVC housing moulded with
assembled VA metal spring and connection cable
with AGV socket
End piece for installation of the VA metal spring
4 each A2 fastening screws, DIN7982
(2.9 x 19mm)
Installation instructions
Information on the product
Scope of delivery

Subject to change. Roto E-Tec Cable junctions IMO_229_EN_v0.July 2012
.9
10.4 11 8.5
20.528
59
16
16
59
Ø 7.5
Information on the product
Dimensions

10
.July 2012
.IMO_229_EN_v0 Roto E-Tec Cable junctions Subject to change.
Due to the large number of profiles and hardware available on the market,
nogenerally applicable information on mounting can be provided, as these
systems differ in several dimensions. Pleasecheck the mounting location and
the available space in the rebate area before the start of mounting.
Mounting location: Window or balcony door rebate
The operation of the connector is restricted to a maximum of 10 plugging
cycles.
Avoid torsion (cable twist) over the entire length of the cable, especially in the
metal spring.
The connector has an anti-twist protection against the danger of polarity
reversal;nevertheless the correct polarity must be ensured prior to each
plugging cycle.
The connector must never be operated when soiled or damp.
7mm dia. drilled holes for cable routing. Deburr drilled holes and check for
chips.
In addition to the generally valid state of technology, particular attention must
be paid to the following sets of technical rules: VDS2311, VDE0100
NOTE!
Install the detachable U-shaped cable junction (see fig.) so that the sash
can be turned open far enough (> 90°).
NOTE!
Leave a cable loop on the permanently mounted end of the spiral
(notthe plug end). This ensures that the cable in the cable junction has
sufficient freedom of movement if necessary when the window or the
door is opened.
Mounting
Advice
Table of contents
Other Roto Door Opening System manuals
Popular Door Opening System manuals by other brands

Normstahl
Normstahl IDO7 installation manual

Häfele
Häfele Finetta T 70 VF manual

AGS
AGS D-PL Instructions for fitting, operating and maintenance

Stanley
Stanley MA900ñ Installation and owner's manual

WITTUR
WITTUR Hydra Plus UD300 Instruction handbook

Alutech
Alutech TR-3019-230E-ICU Assembly and operation manual