Risco lightsys RP432KPP User manual

LCD Keypad &
LCD Proximity Keypad
(Models: RP432KP, RP432KPP)

2
Installing the LightSYS Keypad
Main Panel Back Side
2
1
4 5
6
3

3
Introduction
The user-friendly LightSYS LCD/LCD Proximity keypad enables simple operation and
programming of the LightSYS and ProSYS se urity systems.
The following instru tions offer a brief keypad operation overview. For detailed
information on programming the system, refer to the LightSYS or ProSYS Installer and
User manuals.
Indicators
Power
On
System is operating properly from
AC power, its ba kup battery is in
good ondition and there are no
troubles in the system.
Off No power.
Slow Flash System is in programming.
Rapid Flash System trouble (fault).
Ready
On System is ready to be armed.
Off System is not ready to be armed
Slow Flash System is ready to be armed (set)
while exit/entry zone is open.
Arm (Set)
On System is armed in Full Arm or Stay
Arm (Part Set) mode.
Off System is disarmed (unset).
Slow Flash System is in Exit Delay.
Rapid Flash Alarm ondition.
Stay / Bypass
(Part Set/ Omit)
On System is in Stay Arm (Part Set) or
Zone Bypass (omit) mode.
Off No bypass zones in system.
Tamper
On Zone/keypad/external module has
been tampered.
Off All zones are operating normally.
Fire
On Fire alarm.
Off Normal operation.
Flashing Fire ir uit problem.
LED (Red)
Arm / Alarm Behaves in the same manner as the indi ator.

4
Keys
Control Keys
In Normal Operation mode: Used for Away (Full setting).
In User Fun tions menu: Used to hange data.
In Normal Operation mode: Used for Stay arming (Part
Setting).
In User Fun tions menu: Used to hange data.
Used to disarm (unset) the system after a user ode is
entered;
/OK is used to terminate ommands and onfirm data to be
stored.
Note:
The key is equivalent to the key on ProSYS
keypads.
Used to s roll up a list or to move the ursor to the left ;
Provides the system status.
Used to s roll down a list or to move the ursor to the
right.
Note:
The icon is equivalent to the icon on ProSYS
keypads.
In Normal Operation mode: Used to enter the User Fun tions
menu.
In User Fun tions menu: Used to move ba k one step in the
menu.
Emergen y Keys
Pressing both keys simultaneously for at least two se onds
a tivates a Fire alarm.
Pressing both keys simultaneously for at least two
se onds a tivates an Emergen y alarm.
Pressing both keys simultaneously for at least two se onds
a tivates a Poli e (Pani ) alarm.

5
Fun tion Keys
Used to arm (set) groups of zones (by default) or to
a tivate a prere orded series of ommands (ma ros).
To a tivate press for 2 se onds.
Numeri Keys
Used to input numbers when required.
Keypad Settings
Note:
The following settings must be defined individually for each keypad connected to the system.
To define keypad settings, follow this pro edure:
1. Press for two se onds until the Keypad Settings menu appears.
2. Sele t the relevant i on using the and keys. To enter option, press:
Brightness
Contrast
Keypad's buzzer volume
Language (ProSYS mode only)
Note:
•The LightSyS Language option can always be accessed by simultaneously
pressing and .
•or ProSYS versions prior to 5, set the keypad language according to the panel
language.
Panel RP432/RP128 (ProSYS)
Note:
Select RP432 when the keypad is connected to the LightSYS (default) or RP128
when the keypad is connected to ProSYS.

6
3. Adjust settings with arrow keys. Confirm adjusted settings with .
4. Press to save the adjusted settings.
5. Press to exit the keypad settings menu.
Using the Proximity Tag
The proximity tag, used with the proximity LCD keypad (RP432
KPP) is orre tly used by applying it within a 4 m distan e from
the front of the keypad bottom, as shown at right.
Automatic Upgrade Resulting from Panel Manual Upgrade
Upon initiation of the LightSYS panel remote upgrade (See LightSYS Installer Manual,
Appendix I: Remote Software Upgrade), the keypad software may automati ally also be
upgraded. During this approximately three-minute pro ess an upgrade i on ( ) and
the power i on ( ) are displayed on the keypad and the LED light flashes. Do not
dis onne t during this period
Technical Specifications
Current onsumption
RP432 KP
RP432 KPP
13.8V +/-10%, 48 mA typi al/52 mA max.
13.8V +/-10%, 62 mA typi al/130 mA max.
Main panel onne tion 4-wire BUS, up to 300 m (1000 ft) from Main Panel
Dimensions 153 x 84 x 28 mm (6.02 x 3.3 x 1.1 in h)
Operating temperature -10°C to 55°C (14°F to 131°F)
Storage temperature -20°C to 60°C (-4°F to 140°F)
Prox. RF frequen y 13.56MHz
Complies with EN 50131-3 Grade 2 Class II
Ordering Information
Model Des ription
RP432 KP LightSYS LCD Keypad
RP432 KPP LightSYS LCD Keypad with Proximity 13.56MHz
RP200KT 10 prox keytags (13.56MHz)

7
FCC Note
This device complies with Part 15 of the FCC Rules. Operation is subject to the followin two conditions:
1. This device may not cause harmful interference and
2. This device must accept any interference received, includin interference that may cause undesired operation.
FCC ID: JE4RP432KPP
This equipment has been tested and found to comply with the limits for a Class B di ital device, pursuant to Part15 of the FCC
rules. These limits are desi ned to provide reasonable protection a ainst harmful interference in a residential installation.
This equipment enerates uses and can radiate radio frequency ener y and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no uarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turnin the equipment off and on, the user is encoura ed
to try to correct the interference by one or more of the followin measures:
a. Reorient or relocate the receivin antenna.
b. Increase the separation between the equipment and receiver.
c. Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
d. Consult the dealer or an experienced radio/TV technician.
FCC Warning
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.
Such modifications could void the user's authority to operate the equipment.
RTTE Compliance tatement
Hereby, RISCO Group declares that this equipment is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC. For the EC Declaration of Conformity please refer to our
website: www.risco roup.com.
RISCO Group Limited Warranty
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and
workmanship under normal use for 24 months from the date of production. Because Seller does not install or connect the product
and because the product may be used in conjunction with products not manufactured by the Seller, Seller cannot uarantee the
performance of the security system which uses this product. Seller's obli ation and liability under this warranty is expressly
limited to repairin and replacin , at Seller's option, within a reasonable time after the date of delivery, any product not meetin
the specifications. Seller makes no other warranty, expressed or implied, and makes no warranty of merchantability or of fitness
for any particular purpose.
In no case shall seller be liable for any consequential or incidental dama es for breach of this or any other warranty, expressed or
implied, or upon any other basis of liability whatsoever.
Seller's obli ation under this warranty shall not include any transportation char es or costs of installation or any liability for direct,
indirect, or consequential dama es or delay.
Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any personal
injury or property loss by bur lary, robbery, fire or otherwise; or that the product will in all cases provide adequate warnin or
protection.
Seller, in no event shall be liable for any direct or indirect dama es or any other losses occurred due to any type of tamperin ,
whether intentional or unintentional such as maskin , paintin or sprayin on the lenses, mirrors or any other part of the detector.
Buyer understands that a properly installed and maintained alarm may only reduce the risk of bur lary, robbery or fire without
warnin , but is not insurance or a uaranty that such event will not occur or that there will be no personal injury or property loss
as a result thereof.
Consequently seller shall have no liability for any personal injury, property dama e or loss based on a claim that the product fails
to ive warnin . However, if seller is held liable, whether directly or indirectly, for any loss or dama e arisin under this limited
warranty or otherwise, re ardless of cause or ori in, seller's maximum liability shall not exceed the purchase price of the product,
which shall be complete and exclusive remedy a ainst seller.
No employee or representative of Seller is authorized to chan e this warranty in any way or rant any other warranty.
WARNING: This product should be tested at least once a week.

8
Contacting RISCO Group
RISCO Group is ommitted to ustomer servi e and produ t support. You an
onta t us through our website www.ris ogroup. om or as follows:
United Kingdom
Tel: +44-(0)-161-655-5500
E-mail: support-uk@ris ogroup. om
Fran e
Tel: +33-164-73-28-50
E-mail: support-fr@ris ogroup. om
Italy
Tel: +39-02-66590054
E-mail: support-it@ris ogroup. om
Spain
Tel: +34-91-490-2133
E-mail: support-es@ris ogroup. om
Belgium (Benelux)
Tel: +32-2522-7622
E-mail: support-be@ris ogroup. om
USA
Tel: +1-631-719-4400
E-mail: support-usa@ris ogroup. om
China (Shanghai)
Tel: +86-21-52-39-0066
E-mail: support- n@ris ogroup. om
Israel
Tel: +972-3-963-7777
E-mail: support@ris ogroup. om
RISCO produ t was pur hased from
All rights reserved.
No part of this do ument may be reprodu ed in any form without prior written
permission from the publisher.
© RISCO Group 03/2015 5IN1425 G
This manual suits for next models
2
Table of contents
Other Risco Keypad manuals

Risco
Risco lightsys 2 Instruction manual

Risco
Risco RW132KPPW3 User manual

Risco
Risco Agility RW132KL1P User manual

Risco
Risco Panda RW332K User manual

Risco
Risco RPKELW User manual

Risco
Risco Agility RW132KL1P User manual

Risco
Risco RP432KP02 User manual

Risco
Risco Panda RW332KP User manual

Risco
Risco EL-5829 User manual

Risco
Risco RPKELWP User manual

Risco
Risco RPKELW User manual

Risco
Risco GARDTEC 872 User manual

Risco
Risco lightsys RP432KP User manual

Risco
Risco RW132KPPW3 User manual

Risco
Risco RW332KPP400D User manual

Risco
Risco WL Panda User manual

Risco
Risco Agility 132KP User manual

Risco
Risco RPKELW User manual

Risco
Risco RPKELW User manual

Risco
Risco RW132KL1 User manual