RGBlink DXP H040 User manual

DXP H0404
Article No: RGB-RD-UM-DXP H0404
E001
Revision No: V1.0
USER MANUAL

DXP H0404 User Manual
1
CONTENTS
CONTENTS........................................................................................................................................................ 1
Declarations..................................................................................................................................................... 2
FCC/Warranty...........................................................................................................................................2
Operators Safety Summary......................................................................................................................3
Installation Safety Summary....................................................................................................................3
Chapter 1 Your Product.................................................................................................................................... 5
1.1 In the Box........................................................................................................................................... 5
1.2 Product Overview.............................................................................................................................. 6
1.2.1 Front Panel..............................................................................................................................8
1.2.2 Back Panel...............................................................................................................................9
1.2.3 Dimension.............................................................................................................................10
Chapter 2 Install Your Product....................................................................................................................... 11
2.1 Plug in Signals.................................................................................................................................. 11
2.2 Plug in Main Power..........................................................................................................................11
2.3 Turn on Your DXP H0404..................................................................................................................11
Chapter 3 Use Your Product........................................................................................................................... 12
3.1 LCM Panel Function......................................................................................................................... 12
3.2 MENU Structure...............................................................................................................................13
3.3 Menu Operation.............................................................................................................................. 13
3.4 Remote Control Function.................................................................................................................19
3.5 Ethernet Control.............................................................................................................................. 23
Chapter 4 Ordering Codes..............................................................................................................................28
4.1 Product.............................................................................................................................................28
Chapter 5 Support.......................................................................................................................................... 29
5.1 Contact Us........................................................................................................................................29
Chapter 6 Appendix........................................................................................................................................30
6.1 Specification.....................................................................................................................................30
6.2 Terms & Definitions......................................................................................................................... 31
6.3 Revision History............................................................................................................................... 35

DXP H0404 User Manual
2
Thank you for choosing our product!
This User Manual is designed to show you how to use this video processor quickly and make use of all
the features. Please read all directions and instructions carefully before using this product.
Declarations
FCC/Warranty
Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant
to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area may cause harmful interference, in which case the user will be
responsible for correcting any interference.
Guarantee and Compensation
RGBlink provides a guarantee relating to perfect manufacturing as part of the legally stipulated
terms of guarantee. On receipt, the purchaser must immediately inspect all delivered goods for
damage incurred during transport, as well as for material and manufacturing faults. RGBlink must be
informed immediately in writing of any complains.
The period of guarantee begins on the date of transfer of risks, in the case of special systems and
software on the date of commissioning, at latest 30 days after the transfer of risks. In the event of
justified notice of compliant, RGBlink can repair the fault or provide a replacement at its own discretion
within an appropriate period. If this measure proves to be impossible or unsuccessful, the purchaser can
demand a reduction in the purchase price or cancellation of the contract. All other claims, in particular
those relating to compensation for direct or indirect damage, and also damage attributed to the
operation of software as well as to other service provided by RGBlink, being a component of the system
or independent service, will be deemed invalid provided the damage is not proven to be attributed to
the absence of properties guaranteed in writing or due to the intent or gross negligence or part of
RGBlink.
If the purchaser or a third party carries out modifications or repairs on goods delivered by RGBlink, or if
the goods are handled incorrectly, in particular if the systems are commissioned operated incorrectly or if,
after the transfer of risks, the goods are subject to influences not agreed upon in the contract, all
guarantee claims of the purchaser will be rendered invalid. Not included in the guarantee coverage are
system failures which are attributed to programs or special electronic circuitry provided by the purchaser,
e.g. interfaces. Normal wear as well as normal maintenance are not subject to the guarantee provided by
RGBlink either.
The environmental conditions as well as the servicing and maintenance regulations specified in this
manual must be complied with by the customer.

DXP H0404 User Manual
3
Operators Safety Summary
The general safety information in this summary is for operating personnel.
Do Not Remove Covers or Panels
There are no user-serviceable parts within the unit. Removal of the top cover will expose dangerous
voltages. To avoid personal injury, do not remove the top cover. Do not operate the unit without the
cover installed.
Power Source
This product is intended to operate from a power source that will not apply more than 230 volts rms
between the supply conductors or between both supply conductor and ground. A protective ground
connection by way of grounding conductor in the power cord is essential for safe operation.
Grounding the Product
This product is grounded through the grounding conductor of the power cord. To avoid electrical shock,
plug the power cord into a properly wired receptacle before connecting to the product input or output
terminals. A protective-ground connection by way of the grounding conductor in the power cord is
essential for safe operation.
Use the Proper Power Cord
Use only the power cord and connector specified for your product. Use only a power cord that is in good
condition. Refer cord and connector changes to qualified service personnel.
Use the Proper Fuse
To avoid fire hazard, use only the fuse having identical type, voltage rating, and current rating
characteristics. Refer fuse replacement to qualified service personnel.
Do Not Operate in Explosive Atmospheres
To avoid explosion, do not operate this product in an explosive atmosphere.
Installation Safety Summary
Safety Precautions
For all DXP H0404 processor installation procedures, please observe the following important safety and
handling rules to avoid damage to yourself and the equipment.
To protect users from electric shock, ensure that the chassis connects to earth via the ground wire
provided in the AC power Cord.
The AC Socket-outlet should be installed near the equipment and be easily accessible.

DXP H0404 User Manual
4
Unpacking and Inspection
Before opening DXP H0404 processor shipping box, inspect it for damage. If you find any damage, notify
the shipping carrier immediately for all claims adjustments. As you open the box, compare its contents
against the packing slip. If you find any shortages, contact your sales representative.
Once you have removed all the components from their packaging and checked that all the listed
components are present, visually inspect the system to ensure there was no damage during shipping. If
there is damage, notify the shipping carrier immediately for all claims adjustments.
Site Preparation
The environment in which you install your DXP H0404 should be clean, properly lit, free from static, and
have adequate power, ventilation, and space for all components.

DXP H0404 User Manual
5
Power Adapter
Power Cable
Chapter 1 Your Product
1.1 In the Box
Note:
AC Power Cable supplied as standard according to destination market.
Remote Control

DXP H0404 User Manual
6
1.2 Product Overview
DXP H0404 is a true 4K HDMI Matrix Switcher which allows to route any of 4 HDMI sources to any
4 HDMI displays! The DXP H0404 4×4 HDMI Matrix switch is a complete HDMI routing solution for
True 4K HDMI systems. It supports resolution up to 4K 60Hz @ 4:4:4 and effortless control through
Ethernet control, IR remote control, RS-232 and the front panel.
DXP H0404 System Connection Diagram

DXP H0404 User Manual
7
Features:
Connects up to 4 HDMI sources to 4 x HDMI display monitors.
HDMI 2.0 with 3D, HDCP 2.2 & DVI1.1 Compliant.
Ultra-high-definition video up to 4K 60Hz @ 4:4:4 18Gbps (6Gbps per color)
Support HDR10, Dolby Vision, HLG
Supports up to, Dolby TrueHD, Dolby ATMOS, DTS-HD MA, DTS:X, LPCM 7.1 @ 192KHz
Supports ARC (Audio Return Channel) function.
Multiple control methods: Front panel buttons/ IR remote control/ WebGUI Control/
iOS/Android App Control and RS232 Control.
Built-in LCM screen & LED button at front panel provides quick view of all port connection.
Rack mountable( 1U design)
S/PDIF coaxial audio outputs allow audio to be de-embedded from HDMI outputs
Support HDMI cable lock on each HDMI input/output port

DXP H0404 User Manual
8
1.2.1 Front Panel
No.
Feature
LED Status
Description
1
IR receiver
N/A
Receiving IR remote signal
2
POWER
Blue ON
Power ON
Red ON
Standby
3
LCM Display
N/A
Display operating status or Menu.
4
UP Button
N/A
Go up direction in Menu.
DOWN Button
Go down direction in Menu.
LEFT Button
Go left direction in Menu.
RIGHT Button
Go right direction in Menu.
ENTER Button
Execute selected function
MENU Button
Blue ON
Press to enter Menu or display current
operating status
Press and hold 3 seconds to enable/disable
KEYLOCK
SCENE Button
Save/Load scene
ALL Button
Select all output
OFF Button
Turn off select output
5
OUTPUT Buttons
Blue ON
Press these buttons to select the desired
output
Monitor connected
OFF
No monitor connected
6
INPUT Buttons
Blue ON
Press these buttons to select the desired
input
Video input detected
OFF
No video input

DXP H0404 User Manual
9
1.2.2 Back Panel
1
INPUT HDMI
N/A
HDMI input port 1~4
2
SPDIF
N/A
SPDIF audio output port ~4
OUTPUT HDMI
N/A
HDMI output port 1~4
3
IR
N/A
External IR receiver
4
CONSOLE
N/A
RS232 command control / Firmware update
5
RJ45
N/A
WEB control interface
6
DC JACK
N/A
Power input
Notice
* In standby mode, IR remote cannot control matrix but power on matrix only
* Please press ENTER to execution any change of menu settings
Table of contents