1
MTS-MPM
Multi-Panel Mounting System
2775 E Philadelphia St, Ontario, CA 91761
1-800-330-8678

2
Important Safety Instructions
Please save these instructions.
This manual contains important safety, installation, and operating instructions for the hardware
system. The following symbols are used throughout the manual to indicate potentially dangerous
conditions or important safety information.
WARNING: Indicates a potentially dangerous condition. Use extreme caution when
performing this task.
CAUTION: Indicates a critical procedure for safe and proper operation of the system.
NOTE: Indicates a procedure or function that is important to the safe and proper operation
of the system.
General Safety Information
•Read all of the instructions and cautions in the manual before beginning the installation.
•Do NOT attach solar panel to multi-panel pole mount until mount is securely fit, and pole
base has been secured.
•Chance to strip nuts and bolts exists.
•Multiple people for installation is suggested.
•Do NOT substitute parts from other manufacture ring sources, doing so may void the
warranty and/or result in an unstable system
•This system is NOT possessing any compliance with residential structural codes and
should not be used in place of a system that is, if so required by local regulations
Installer Responsibilities
•Installation compliance with any applicable codes which are enforced at the installation
site.
•Installation compliance and compatibility with all system components and the environment
including but not limited to roofing, system components, etc.
•Verification that all project information is accurate
•Ensure proper array structure grounding, including each module frame and the mounting
pole. Failure may result in damage to your equipment. Do NOT rely on mounting pipe to
act as grounding rod! It is not a reliable substitute.

3
WARNING: these instructions are intended to be used by individuals with sufficient
technical skills for the task. Knowledge and use of hand tools, measuring devices, and
torque equipment is also required
WARNING: Electrocution Hazard! Check for clearance to overhead power lines before
bringing any installation.
WARNING: Watch your hands and fingers! Wemake every effort to remove sharp edges
from the galvanized products. However, we still recommend installers wear gloves
when handling these mounts in order to avoid the sharp edges.
WARNING: The mount is heavy! Depending on the modules you are using, the weight
will only increase. Therefore, it is recommended to have the aid of another person
and/or lifting devices that can help install this safely. Failure to observe this warning
can hurt or kill you.

4
Table of Contents
General Information.........................................................................................................................................5
Material List..........................................................................................................................................................5
Installation.............................................................................................................................................................9
Foundation.................................................................................................................................................. 10
Compatibility with Renogy Panels..................................................................................................... 11
1- Install Base Column on the Foundation...................................................................................... 12
2- Install Connector on Base Column................................................................................................ 12
3- Install Main Girder and Angle Adjustment Connector.......................................................... 13
4- Install Cross Beams on Main Girder............................................................................................. 14
5- Install Solar Panels with End Clamps and Mid Clamps ........................................................ 15
6- Check All Parts to Ensure Safety.................................................................................................... 17
Check all screws and clamps to make sure all parts are securely installed....................... 17
Maintenance...................................................................................................................................................... 17
Technical Specifications........................................................................................................................... 17
Compatibility..................................................................................................................................................... 18

5
General Information
The Renogy MTS-MPM is designed for off-grid applications when mounting on a roof is not ideal.
Composed of high strength steel and corrosion resistant welded components, the MTS-MPM can
support up to 400 Watts of power. The system comes complete with all fasteners to adhere panels
to the mounting surface. This system makes the installation solar systems, easy, affordable, and
quick.
Key Features
•Galvanized Steel and Anodized Aluminum Alloy construction
•High-tensile strength and corrosion free fasteners
•Precision hole positioning and alignment
•Compatible with multiple Renogy PV sizes—(4) 100W Mono, (2) 160W Mono, (1) 270W
Poly, (1) 300W Mono
•Secures most 100W-350W PV modules
•Mount up to 400W on a single pole
•Standard design can withstand up to 75mph wind
Material List
Image
Component
Size / in
Qty.
Material
Base Column
4.3(diameter)x
59.1
1
Q235
Steel

6
Connector
4.5(diameter)x
5.91
1
Q235
Steel
Angle Adjustment
Connector
1.2x1.2x12.8
1
Q235
Steel
Main Girder
2.4x2.4x78.8
1
Q235
Steel
Cross Beam
1.6x1.6x63.0
4
Q235
Steel
End Clamp Piece
1.5x1.6x1.6
8+(2)
spare*
H35
Aluminum

7
Mid Clamp Piece
1.4x1.0x2.0
4+(1)
spare*
H40
Aluminum
Strut Channel Nut
with Plastic Wing
2.0x1.3x0.7
12+(2)
spare*
Plastic
and steel
Positioning Plate
for Base Column
7.9x7.9x0.3
1
Q235
steel
U-Bolt for Base
Installation
7.1x6.0x0.4(di
ameter)
2
Q235
Steel
Socket Head
Screw
M8 x 50
14+(2)
spare*
S304
Stainless
Steel
Socket Head
Screw
M8 x 20
2+(1)
spare*
S304
Stainless
Steel

8
Socket Head
Screw
M10 x 20
8+(2)
spare*
S304
Stainless
Steel
Socket Head
Screw
M12 x 100
1+(1)
spare*
S304
Stainless
Steel
Hex Nut
M8
2+(2)
spare*
S304
Stainless
Steel
Hex Nut
M10
12+(2)
spare*
S304
Stainless
Steel
Hex Nut
M12
1+(1)
spare*
S304
Stainless
Steel
Split Lock Washer
M8
10+(2)
spare*
S304
Stainless
Steel
Split Lock Washer
M10
8+(2)
spare*
S304
Stainless
Steel

9
Split Lock Washer
M12
1+(1)
spare*
S304
Stainless
Steel
Flat Washer
M8
10+(2)
spare*
S304
Stainless
Steel
Flat Washer
M10
8+(2)
spare*
S304
Stainless
Steel
Flat Washer
M12
1+(1)
spare*
S304
Stainless
Steel
*Spare parts serve as safety margins for installation, spare parts quantity is not guaranteed.
Installation
Renogy assumes no responsibility for your foundation installation. Consult a local
professional for proper installation.
Recommended tools to have before installation (Not provided):
•Standard Wrench Set
•Standard Socket Set
•Allen Wrenches
•Level
•Tape Measure
•Screwdrivers
The above tools and equipment are highly recommended to have available to assist
with installation but are in no way a comprehensive list of tools. Installers feel free to
substitute comparable equipment where appropriate.

10
Foundation
WARNING! Windy conditions can exert extreme forces on the PV array, foundation, and
mounting mast of your array.
WARNING! Keep hands clear of pinch points!
NOTE: Choose an optimum solar location that is free from obstructions such as trees and
buildings.
The recommend installation method involves using the provided 2 pieces of U-Bolt, positioning
plate with a cement foundation that users must create. The cement foundation recommended is
a 20” x 20” concrete block square with the positioning plate on top and U-bolt inside. The
foundation may vary depending on soil and location. It is recommended, and in some locations,
required, to seek the advice and or approval of a licensed Professional Engineer familiar with
your local codes and requirements prior to construction.
Table of contents
Other Renogy Rack & Stand manuals
Popular Rack & Stand manuals by other brands

Salamander
Salamander Acadia AC/W/L400/WH Assembly instructions

Fohhn
Fohhn VAT-09 Mounting instruction

ricoo
ricoo FS0522 quick start guide

AMSOIL
AMSOIL BMK-22 Installation and service instructions

Kargo Master
Kargo Master 48220 installation guide

Milestone AV Technologies
Milestone AV Technologies SIMPLICITY SLF2 installation instructions