REITEL INDURET COMPACT User manual

Operating Instructions
LABORGERÄTE IN
STAINLESS STEEL
INDURET COMPACT
REITEL Feinwerktechnik GmbH
Senfdamm 20 | 49152 Bad Essen
Phone: +49(0)5472-9432-0 | Fax: +49(0)5472-9432-40
www.reitel.com | info@reitel.com

II
Dear Customer!
The INDURET COMPACT induction casting machine guarantees optimum and safe casting
results for all dental work, including model casting.
Any other use or use beyond this is deemed improper. For resulting damage the
user/operator of this device is solely responsible. Prior to installation of the device operating
instructions and especially the safety instructions must be read and followed by all personnel
who use this device. After having unpacked the device, please check carefully whether
transportation damages of any kind have occurred. If that is the case, the carrier or
manufacturer must be notified within 3 days. The company will not be responsible for any
damages found after that.
These operating instructions must be read and followed by all personnel who use this device.
To ensure quick access we recommend to keep it at a safe place near the device. In case of
loss it can be ordered at a nominal fee from the manufacturer. This document is protected by
the copyright law. Passing on or duplication of this document or extracts thereof, evaluation
and communication of its contents are not authorised. In case of loss it can be ordered at a
nominal fee from the manufacturer.

III
INDEX
TECHNICAL DESCRIPTION......................................................................................... 5
BASIC EQUIPMENT....................................................................................................... 5
SPECIAL ACCESSORIES................................................................................................ 5
OPERATING ELEMENTS................................................................................................ 6
TECHNICAL DATA......................................................................................................... 8
SAFETY NOTES........................................................................................................... 9
GENERAL SAFETY NOTES ............................................................................................ 9
SPECIFIC SAFETY INSTRUCTIONS ................................................................................10
INSTALLATION ...........................................................................................................11
INSTALLATION.............................................................................................................11
COMPRESSED AIR CONNECTION ..................................................................................12
PROTECTIVE GAS CONNECTION (OPTIONAL)..................................................................12
WATER CONNECTION..................................................................................................14
CONNECTION FOR POWER SUPPLY...............................................................................14
GENERAL NOTES.......................................................................................................15
ALLOYS......................................................................................................................15
CLEAN WORKING AREA FOR PRECISE CASTING..............................................................15
ARIGHT WAY..............................................................................................................16
CRUCIBLES AND STOP RODS........................................................................................18
THE CONTROL PANEL..................................................................................................19
PROGRAMMING THE MEMORY LOCATIONS.....................................................................19
CASTING PROCESS...................................................................................................20
THE CASTING PROCESS WITH TEMPERATURE CONTROL.................................................21
5.1.1 The casting process with temperature control without pre-melting............................................. 21
5.1.2 The casting process with temperature control with pre-melting .................................................. 22
THE CASTING PROCESS WITHOUT TEMPERATURE CONTROL...........................................23
5.2.1 The casting process without temperature control without pre-melting ....................................... 23
5.2.2 The casting process without temperature control with pre-melting............................................. 23
BRIDGING THE POWER REDUCTION ..............................................................................23
AFTER THE CASTING ...................................................................................................24
TROUBLESHOOTING .................................................................................................25
MAINTENANCE...........................................................................................................25

IV
WARRANTY.................................................................................................................26
RULES FOR DISPOSAL..............................................................................................29
SPARE PARTS LIST ...................................................................................................30
EC CONFORMITY DECLARATION.............................................................................31

5
Technical description
Basic Equipment
•INDRET COMPACT
•1 Ceramic crucible (non-precious alloy)
•1 Graphite crucible (EM)
•1 Graphite crucible holder
•1 Ceramic stop rod
•1 Graphite stop rod
•1 Thermocouple
•1 Hose package
•User video
Special Accessories
•Order-No.: 21601000 Pressure reducer Argon
•Order-No.: 23801000 Graphite crucible for precious alloy
•Order-No.: 23801200 Graphite crucible Plus for precious alloy
•Order-No.: 23802000 Graphite stop rod
•Order-No.: 23803000 Ceramic crucible for non-precious alloy
•Order-No.: 23804000 Ceramic stop rod S
•Order-No.: 23805000 Graphite crucible holder
•Order-No.: 23806000 Crucible holder
•Order-No.: 23807000 Water cooling unit
•Order-No.: 23809000 Maintenance unit
•Order-No.: 23811000 Starter package including order-no.:
21601000, 23801000, 23802000, 23803000, 23805000, 23809000,
23812000, 23815000, 23816000, 23818000, 23819000, 23823000
•Order-No.: 23812000 Longlife stop rod
•Order-No.: 23814000 Thermocouple
•Order-No.: 23815000 Centering and isolation rings
•Order-No.: 23816000 Milling tool for crucible outlet
•Order-No.: 23818000 Alloy chute
•Order-No.: 23828000 Dosage tube
•Order-No.: 23819000 Positioning pliers
•Order-No.: 23822000 PC interface

6
Operating Elements
1 Pressure gauge for pillar frame
2 Control lamp „performance reduction“
3 Switch “Manual Argon rinsing”
4 Sight glass
5 Inductor chamber
6 Clamping lever
7 Mould’s chamber
8 Lamp „Argon rinsing“
9 Power switch
10 Lamp step 1 draw vacuum
11 LED Casting machine “ready for operation”
12 Temperature control
13 Control lamp step 2 lift pestle (casting)
14 Control lamp step 3 Pressurisation (automatic)
15 Stew switch
16 LED “Heating on”
17 LED “Error”
18 Heating control
19 Device fuse 4 A
20 Device fuse 1 A
21 Power supply for water cooling unit
22 Type plate
23 Power outlet
24 Argon connection
25 Air connection
26 Water drain
27 Water outlet
28 Sound absorber
29 Air filter
30 Selector switch pressurization medium “Argon / air”
31 Display „Heating disturbance“
32 Reset für heating disturbance

7
Fig.: INDURET COMPACT
Fig.: Back view
31
3
4
5
15
6
7
2
8
13
11
10
12
14
9
18
17
16
30
32
19
21
22
23
24
25
26
27
28
29
20
1

8
Technical Data
Line voltage
230 V/50-60 Hz
Current consumption
3.600 W
Height/width/depth
390/310+40/650 mm
Weight
38 kg
Air pressure/Argon pressure
6 bar
Water pressure
min. 3-4 bar
Casting ring size
1–9 incl. model casting
Temperature
max. 1.600 °C
Sound level
≤70 dB(A)
Housing
stainless steel
Order-No.:
13800000
Made in Germany (Subject to modifications)

9
Safety Notes
General Safety Notes
•All equipment undergoes final inspection and testing before leaving our factory. However,
if equipment is damaged during shipping or through any other circumstances, it must not
be used in service. Please check the device regularly for damages. Damaged parts
should be replaced immediately.
•All power/air/water/gas sources should be rated for the demands of the device as listed in
the technical data sheets. Maximum ratings must not be exceeded. All VDE (Verein
Deutscher Elektro-Ingenieure) standards should be followed. Equipment should be
grounded according to standards.
•Adherence to valid regulations regarding necessary checks (e.g. according to Accident
Prevention & Insurance or electrical equipment) is exclusively taken over by the
buyer/user of this product.
•This device has been designated to be used only for its intended purpose. All other
applications must be prohibited for safety reasons as otherwise the manufacturer’s
warranty expires.
•The device may only be used by persons who have been instructed in the handling and
have been expressly commissioned with the operation.
•The device should be set-up in a clean, well-ventilated room, if necessary under a hood.
•Supporting surfaces should be straight, flat and adequately stable.
•Don’t place anything on top of the machine.
•To avoid injury, appropriate protection should be worn (e.g. gloves, safety glasses, safety
shoes, hearing protection etc.)
•If the machine is defective or working improperly it must be taken out of service. In case
of further use of the machine the owner will be held responsible for any consequential
damage.
•To prevent accidents from water, fire or explosion, all power/air/water/gas sources should
be turned off after working hours and during breaks, and secured against unauthorized
access.
•When carrying out maintenance works or repairs or when opening the device always turn
off the main power switch and unplug the whole unit.
•Repairs should be carried out only by the manufacturer or by qualified and certified
personnel appointed according to chapter 7 –warranty.
•In case of suspected ingress of liquid stop operation and contact Service.
•Check all hose joints for tightness, if necessary fasten clamps.

10
Specific Safety Instructions
•Never store explosive, highly inflammable or burnable material in the working area.
•Only put the hot crucibles, pestles and moulds on a heat-resistant and fireproof support.
•Only use the device for melting metals and alloys in the crucibles intended for this
purpose.
•Do not melt materials that produce toxic gases.
•Only switch on the generator with inserted melted material.
•Do not reach into the inductor chamber when the heater is on.
•Use pliers when inserting and removing the casting rings or melting crucibles. There is a
risk of burns.
•Only open the casting chambers if there is no overpressure or underpressure.
•Handle gas cylinders carefully, do not heat them and protect them from falling over.
•Alloys with a longer melting time are not permitted. The rest period between a casting
and the start of a new heating process must be at least 6 minutes. During this time, no
hot crucible should be in the device. Casting ring chamber and inductor chamber must be
open during this time for cooling reasons.
•Small metal quantities below 15 g are inaccurate and difficult to melt due to lack of mass.
If it comes to mishandling, often cause errors in embedding or a wrong temperature
assessment of the molten metal.
•Precious metal (EM) is usually cast in the graphite crucible, if necessary in the ceramic
crucible with the graphite crucible holder.
•When melting thin and few precious metal platelets, make sure that they do not stand
upright, otherwise no coupling takes place and the metal does not melt. Therefore push
the plates together, place old cast cones on the new material or weld or score the plates
together.
Pay attention to the maximum percentage of old material and shred it enough! The parts
must lie on the bottom of the pot, otherwise there is no or only partial metal melting.
•The heating process may include max. 3 minutes. Alloys with a longer melting time are
not permitted.
Note:
The machine must not be used by persons with electronically controlled medical
aggregates such as pacemakers.