Regency Freestanding Woodstove 7
INSTALLATION
RESIDENTIAL
INSTALLATION
1) Please read this entire manual before you
install and use your new woodstove. Failure
to follow instructions may result in property
damage, bodily injury or even death. Be aware
that local Codes and Regulations may override
some items in this manual. Check with your
local inspector.
2) Select a position for your Regency Stove.
Consult the minimum clearance chart for your
model and set the stove in place. For close
clearance installation use listed double wall
connector systems.
3) To insure vertical alignment, suspend a plumb
bob from the ceiling over the exact center of
your stove ue and mark a spot on the ceiling
to indicate the center of the chimney.
4) Check that the area above the ceiling is clear
for cutting. Re-conrm the clearance from the
stove to combustibles to insure that they are
within the prescribed limits.
5) Install chimney according to chimney manu-
facturers instructions. The performance of your
woodstove is governed to a very large part by
the chimney system. Too short a chimney can
cause dicult start-up, dirty glass, backsmok-
ing when door is open, and even reduced
heat output. Too tall a chimney may prompt
excessive draft which can result in very short
burn times and excessive heat output. The
use of an inexpensive ue pipe damper may
be helpful in reducing excessive draft.
Caution: The correct diameter of the chimney
for the appliance is 150 mm and the correct
type of chimney is specied on pages 8 and
9 of the manual.
6) Mark the location of the pedestal base or legs
on the oor, then move the stove aside and
mark the position of the oor protector.
7) The appliance must be installed on a oor
protector as specied on pages 8 - 9 of these
instructions and the oor proctector must
extend at least 300 mm in front of the door
opening and 200 mm to either side of that
opening.
8) When the oor protection is complete, position
the stove with the ue collar centered under
the installed chimney.
9) New Zealand installations require unit be
installed with seismic restraint.
Legs of unit should be bolted down through
leg holes - leg unit / and through holes on
pedestal - pedestal unit. Seismic restraints
must pass through the oor protector and be
secured in the oor below.
WARNING: THE APPLIANCE AND
FLUE-SYSTEM SHALL BE IN-
STALLED IN ACCORDANCE WITH
AS/NZS 2918 AND THE APPROPRI-
ATE REQUIREMENTS OF THE REL-
EVANT BUILDING CODES.
WARNING: APPLIANCES IN-
STALLED IN ACCORDANCE WITH
THIS STANDARD SHALL COMPLY
WITH THE REQUIREMENTS OF AS/
NZS 4013 WHERE REQUIRED BY
THE REGULATORY AUTHORITY, i.e.
THE APPLIANCE SHALL BE IDENTI-
FIABLE BY A COMPLIANCE PLATE
WITH THE MARKING 'TESTED TO
AS/NZS 4013'
ANY MODIFICATION OF THE APPLI-
ANCE THAT HAS NOT BEEN AP-
PROVED IN WRITING BY THE TEST-
ING AUTHORITY IS CONSIDERED T
BE IN BREACH OF THE APPROVAL
GRANTED FOR COMPLIANCE WITH
AS / NZS 4013
CAUTION: MIXING OF APPLIANCE
OR FLUE-SYSTEM COMPONENTS
FROM DIFFERENT SOURCES OR,
MODIFYING THE DIMENSIONAL
SPECIFICATIONS OF COMPONENTS
MAY RESULT IN HAZARDOUS
CONDITION. WHERE SUCH ACTION
IS CONSIDERED, THE MANUFAC-
TURER SHOULD BE CONSULTED IN
THE FIRST INSTANCE
CAUTION: CRACKED AND BROKEN
COMPONENTS, E.G. GLASS PAN-
ELS OR CERAMIC TILES, MAY REN-
DER THE INSTALLATION UNSAFE.
WARNING: DO NOT USE FLAM-
MABLE LIQUIDS OR AEROSOLS TO
START OR REKINDLE THE FIRE.
WARNING: DO NOT USE FLAM-
MABLE LIQUIDS OR AEROSOLS IN
THE VICINITY OF THIS APPLIANCE
WHEN IT IS OPERATING.
WARNING: DO NOT STORE FUEL
WITHIN HEATER INSTALLATION
CLEARANCES.
WARNING: OPEN AIR CONTROL
(AND DAMPER WHEN FITTED) BE-
FORE OPENING FIRING DOOR.
CAUTION: THIS APPLIANCE
SHOULD NOT BE OPERATED WITH
CRACKED GLASS.
CAUTION: THIS APPLIANCE
SHOULD BE MAINTAINED AND
OPERATED AT ALL TIMES IN AC-
CORDANCE WITH THESE INSTRUC-
TIONS.
CAUTION: THE USE OF SOME
TYPES OF PRESERVATIVE-TREAT-
ED WOOD AS A FUEL CAN BE
HAZARDOUS.
10) Do not connect this unit to a chimney serving
another appliance.
11) Your Regency Woodstove is not to be connected
to any air distribution duct.