www.reefe.com.auAscento Group Australia P: 1800 807 604 VER.2023.08.09 3
READ THIS MANUAL CAREFULLY BEFORE INSTALLATION AND BEFORE STARTING THE PUMP.
APPLICATIONS AND CONDITIONS
Pumps of REEFE VMR models are non-self-priming vertical multistage centrifugal pumps. Their features
are high eciency, low noise, light corrosive liquid resistance, compact structure, good appearance, small
volume, light weight, easy to service, good seal performance, and covered by REEFE warranty and customer
service.
i. Applications
• Pumped liquids: low viscosity, neutral, non-explosive liquids. Not containing solid particles or fibers.
The liquid must not be of a corrosive nature thereby being capable of attacking the pump materials
chemically.
• Boiler water supply and condensing system.
• Water treatment, filtration system.
• Food and beverage industries.
• Pressure boosting in high-rise buildings.
• Farmland irrigation, nursery irrigation and golf court irrigation.
• Industry cleaning system.
• Liquid conveying, circulation and boosting.
• Hot and cool water.
ii. Operation Conditions
• Medium temperature: Normal temperature type -15°C+70°C; Hot water type-15°C~ +120°C.
• Flow: 0.4~180m3/h
• Medium pH range: pH 5-9.
• Maximum ambient temperature: +40°C.
• Maximum altitude: 1000 m; derate when higher.
• Minimum inlet pressure: Refer to catalogue for specific model of pump.
Caution: When pumping liquids with a density and/or viscosity higher than that of water, use motors with
correspondingly higher outputs, if required.
DEFINITION OF MODEL
MODEL SPECIFICATIONS
VMR5-16 Voltage input 1-240VAC; Current 12.4A
Rated Head 85M; Rated Flow 1.39L/sec
VMR10-7T Voltage input 3-415VAC; Current 6.76A
Rated Head 54M; Rated Flow 2.78L/sec
VMR10-12T Voltage input 3-415VAC; Current 8.79A
Rated Head 92M; Rated Flow 2.78L/sec
VMR20-5T Voltage input 3-415VAC; Current 11.9A
Rated Head 58M; Rated Flow 5.56L/sec
VMR20-7T Voltage input 3-415VAV; Current 15.84A
Rated Head 82M: Rated Flow 5.56L/sec