RedRat RedRat-X Quick setup guide

The RedRat-X
Integration Guide

Contents
1 Introduction .................................................................................................................................... 3
2 Overview of the RedRat-X ................................................................................................................ 3
2.1 Front ........................................................................................................................................ 3
2.2 Rear ......................................................................................................................................... 3
3 RedRat Applications ......................................................................................................................... 4
3.1 RedRat evice Manager ........................................................................................................... 4
3.2 Signal atabase Utility ............................................................................................................. 4
3.3 RedRat Scheduler ..................................................................................................................... 4
3.4 TestManager ............................................................................................................................ 4
3.5 RedRat Hub .............................................................................................................................. 4
3.6 RedRat Control ......................................................................................................................... 5
4 Platform Support ............................................................................................................................. 5
5 RedRat Hub - Sending Commands from Applications ....................................................................... 5
6 Using the RedRat S K ...................................................................................................................... 6
6.1 RedRat-X iscovery .................................................................................................................. 6
6.2 Simple Communication Tasks ................................................................................................... 6
6.3 IR Signal Output ....................................................................................................................... 7
6.3.1 Using the Front IR Blaster ................................................................................................. 7
6.3.2 Using the Rear IR Ports ..................................................................................................... 8
6.4 IR Signal Input .......................................................................................................................... 8
6.4.1 The Wide-Band etector .................................................................................................. 8
6.4.2 The Narrow-Band etector ............................................................................................... 9
6.5 Handling USB Plug Events ....................................................................................................... 10
7 Porting RedRat3-II Applications to the RedRat-X ............................................................................ 11
7.1 USB evice iscovery ............................................................................................................. 11
7.2 RedRat-X Connect and isconnect ......................................................................................... 12
8 Using RF Modules .......................................................................................................................... 12

1 Introduction
The RedRat-X is the latest RedRat device for automating control of TVs, STBs and other audio-visual
equipment. It combines features of both our irNetBox networked product and the USB RedRat3-II
device, plus provides additional support for Bluetooth and RF4CE remote controls through the use of the
correct RF module.
Whether you are a new RedRat user or need to replace the use of older RedRat devices with a RedRat-X,
this guide is intended to help integrate it into your software infrastructure, or to write new software
applications from scratch.
2 Overview of the RedRat-X
2.1 Front
IR Blaster:
A high-powered IR blaster, positioned behind the centre of the front panel. The power output
is controllable by software in steps from 0 (off) to 100 (max).
LEDs:
Multi-coloured LE s indicate the operational state of the unit, please see the
User Guide
for
details. The LE colour and brightness are also adjustable via software control, so applications can use
this to indicate the state or provide feedback.
2.2 Rear
USB:
The RedRat-X is powered via its USB port. This can be connected to a computer, and in which case
USB will also be used to control the unit.
Network:
Ethernet control can be used in a very similar manner to the irNetBox. The device needs to be
powered via the USB port using an external PSU. For full EMC compliance (CE and FCC), RedRat are able
to supply a PSU which has been tested with the RedRat-X.
IR Output Ports:
Three IR output ports are available for use with stick on IR emitters for individual
control of STBs. The output power for each port is separately controllable, from 0 (off) to 100 (max).
Each port can be set to operate in current drive mode (default for driving IR LE s) or in voltage drive
mode (for interfacing with IR distribution systems).

3 RedRat Applications
We provide a number of applications for use with RedRat devices which meet the requirements of many
RedRat customers. An overview is provided here, but more detailed information about each application
can be found on our website – www.redrat.co.uk.
Unless otherwise stated, these applications run on Microsoft Windows only (Windows 7 or greater)
using the .NET Framework.
3.1 RedRat evice Manager
This is used for initial device installation, configuration and testing, for example to validate that
communication between your computer and the device works and that it can then control the TVs/STBs
required. The application should also be used periodically to check for firmware updates, which it can
then automatically download from the RedRat website.
3.2 Signal atabase Utility
RedRat devices are primarily designed for the input/output of infrared remote control signals, which
need to be captured from the TV/STB’s original remote control. The Signal B Utility is used to do this,
storing the IR data in files (XML format) for direct use in other RedRat applications and with the S K. The
IR data can also be exported in other formats for use in different applications or on different platforms.
3.3 RedRat Scheduler
If it is necessary to setup a set of remote control operations to happen at particular times, then the
Scheduler application can be used to do this. Individual signals or short sequences of signals (macros)
can be programmed to be sent at certain times or at regular intervals.
3.4 TestManager
A more advanced application for both interactive and script based control for banks of STBs.
With interactive control, graphical representations of STBs can be created and by simply selecting them,
an on-screen remote control can be used to control them.
Script based control supports a simple in-built scripting language or python based scripting to automate
repetitive procedures or tests.
3.5 RedRat Hub
A console/terminal server application which supports straightforward integration of RedRat devices with
third party software. In effect, it looks after all communication with RedRat devices and IR signal
management, accepting simple commands from client applications which are sent via a socket. Its use is
discussed in more detail in section 5.
This application runs on Linux as well as Windows.

3.6 RedRat Control
Most of the applications described so far are intended for the output of IR signals to control TVs and
STBs. RedRat Control operates differently in that it is designed to allow control of applications on a PC
via infrared remote control. For example, if a media player is running, RedRat Control can be configured
to respond to IR commands from a remote control handset and send appropriate instructions (play,
pause etc) to the media player.
4 Platform Support
Historically, software for RedRat devices has been developed on Microsoft Windows using the .NET
framework, so this is where there is still the best RedRat device support. However, many applications,
particularly larger scale STB testing systems often use Linux, so we have now ensured that the RedRat-X
is supported on Linux.
The RedRat core code (RedRat.dll) will run on both Windows and on Linux/Macs using Mono.
Applications using the console/terminal window and not using any Windows-specific functionality will
therefore also run using Mono. At present, Windows applications using a GUI interface (WinForms or
WPF) will not run on Linux or Macs, though developing cross-platform GUI applications is a potential
future area of development.
With the RedRat-X, both USB and network communication is supported on Windows and Linux.
5 RedRat Hub - Sending Commands from Applications
RedRat Hub provides perhaps the most straightforward mechanism for integrating RedRat devices with
third party software.
When RedRat Hub starts, it loads any required IR datasets and then establishes communication with
RedRat devices. Client applications then open a socket to RedRat Hub and send quite simple commands,
such as:
ip="192.168.1.40" dataset="Sky+" signal="play" output="3"
This will send the IR signal play from the SKY+ dataset via output 3 of the RedRat device found at the
given IP address (irNetBox or RedRat-X).
name="RRX 1" output="4" dataset="SKY+" signal="play"
The second example sends the same signal via output 4 (blaster output) on the RedRat-X with the name
“RRX-1”.
RedRat Hub is a very scalable application in that it can support a large number of client applications (in
the 100s) concurrently sending commands to RedRat devices. It manages any resource contention, i.e. it
will ensure that commands are sent to RedRat devices in a manner that they can handle.
Example client code is available for C#, Java, Python, Perl and PHP.

6 Using the RedRat S K
The RedRat S K is basically a .NET assembly (RedRat.dll) which contains all the low-level code for:
1. RedRat device discovery
2. evice communication, whether by Ethernet or USB
3. IR signal data management
4. Low-level RF module support
The API presented for application development is quite straightforward to use, and working with the
RedRat-X should be quite familiar to those who have written code for other RedRat devices in the past.
RedRat.dll version 4.15 or greater is needed for full RedRat-X support. It runs on both Windows (using
the .NET framework V4.5.1 or above) and on Linux (using Mono).
Most of the code examples shown below are taken from the RedRatX-Demo project in the RedRat
samples solution, which can be downloaded from the S K section on the website.
6.1 RedRat-X iscovery
evice discovery takes place by:
• Enumerating USB devices
• A network search using a U P broadcast.
There are a number of ways to do this, or do selective searches, but perhaps the most straightforward
way to find all RedRat-Xs is:
var rrxLis = RRUtil.FindRedRats( LocationInfo.RedRatType.RedRatX );
A list of generic LocationInfo objects are returned, which contain details about the RedRat device. This
search will take a few seconds to return as it waits for responses from the network broadcast. If only
USB devices are going to used, then it can be made almost instantaneous by limiting the search:
var rrxLis = RRUtil.FindRedRats( LocationInfo.RedRatType.RedRatX_US );
Assuming that there is at least one element in the list, the actual RedRat-X object for the first element in
the list is obtained so:
var rrx = RedRatX.GetInstance( rrxLis[0] )
The rrx object is of type RedRatX regardless of whether it is connected via USB or via the network.
6.2 Simple Communication Tasks
Before any operations with the actual device can take place, the code must first connect with the
RedRat-X. This code below shows connecting to the RedRat-X, obtaining the firmware version, blinking
the front LE s 5 times and then disconnecting:

rrx.Connect();
// Use the RRX a bit
Console.WriteLine( $"Using RedRat-X '{rrxLi.Name}'" );
Console.WriteLine( $"Firmware version: {rrx.FirmwareVersion}" );
// link the lights a few times
Console.WriteLine(" linking the LEDs...");
for ( var i = 0; i < 5; i++ )
{
rrx. link();
Thread.Sleep( 750 );
}
rrx.Disconnect();
6.3 IR Signal Output
The RedRat-X has four IR outputs, which in code are referred to as outputs 1 to 4:
Output Number Function
1 Output port 1 on back of case
Output port 2 on back of case
3
Output port
3 on back of case
4
Front IR blaster
6.3.1 Using the Front IR Blaster
To make the API’s use similar to that of the RedRat3-II, if no output ports are enabled and the simple
synchronous OutputModulatedSignal method is used, this will transmit the signal via the front blaster.
// Output an IR signal via the blaster
rrx.OutputModulatedSignal( sig );
Console.WriteLine( "IR out via blaster using sync API" );
The async API can also be used where higher IR output throughput is required and concurrent IR
transmission is needed from the rear IR ports and the blaster. The code below will output an IR signal 5
times from the front blaster:
// Using the ASYNC API, all ports need to be explicitly set
var opList = new OutputList { new OutputPort( RedRatX.IR_ LASTER_PORT, 60 ) };
var mutex = new ManualResetEvent(false);
for (var i = 0; i < 5; i++)
{
rrx.OutputIRPacketAsync(GetSignal(), opList, 100, null, ar =>
{
Console.WriteLine($"IR out via blaster using async API.");
mutex.Set();
});
mutex.WaitOne(); // Wait for IR output completion
Thread.Sleep(750); // Wait a bit longer
}

In the above example, the RedRatX.IR_ LASTER_PORT constant gives the port number for the blaster.
The value 60 passed to the OutputPort() constructor is the power to use, in this case 60% of maximum.
Another point to note with the async API is that the OutputIRPacketAsync() method returns
immediately so a mutex is used to block thread execution until execution is complete. The last
parameter to the OutputIRPacketAsync() method is a callback that is executed on IR signal completion,
and in this case is used to set the mutex so that the waiting thread can continue.
6.3.2 Using the Rear IR Ports
These work in an identical fashion to irNetBox output ports. The code blow uses the sync API to send an
IR signal via output 2 at 30% power:
var opList = new OutputList { new OutputPort( 2, 30 ) };
rrx.EnabledIROutputs = opList;
rrx.OutputModuledSignal( sig );
Using the async API is identical to the IR blaster example, except the rear IR ports are selected rather
than the front blaster.
6.4 IR Signal Input
As with the RedRat3-II device, the RedRat-X has two IR detectors for different purposes as described
below.
6.4.1 The Wide-Band etector
This allows the device to sample the raw IR signal, so is used for IR signal capture/learning. It is fairly
short range in operation, the recommended distance being between 1m and 2m. The irNetBox also has
this detector for IR learning/capture.
var mutex = new ManualResetEvent( false );
EventHandler learningSignalInHandler = ( s, ea ) =>
{
var siea = ea as SignalEventArgs;
if ( siea == null ) return;
if ( siea.Action == SignalEventAction.MODULATED_SIGNAL )
{
Console.WriteLine( $"IR signal:\n{siea.ModulatedSignal}" );
}
else if ( siea.Action == SignalEventAction.INPUT_CANCELLED )
{
Console.WriteLine( "Timeout when waiting for IR signal." );
}
mutex.Set();
};
// Hook up the incoming event handler just for this operation.
rrx.LearningSignalIn += learningSignalInHandler;
// Set the RR-X up for IR signal input and allow 10s for the RCU button press.
rrx.GetModulatedSignal( 10000 );
mutex.WaitOne();
rrx.LearningSignalIn -= learningSignalInHandler;

6.4.2 The Narrow-Band etector
This is exactly the same kind of detector as is used in TVs and STBs, tuned to a particular IR signal
modulation frequency, but with a long range of 10m or more. The default value of this detector’s
frequency is 38KHz as this is the most common remote control carrier frequency, however we can
replace it with a detector at another frequency if requested. The most common carrier/modulation
frequencies are 36KHz, 38KHz and 56KHz.
The intended use of this detector is to allow control of the computer, or applications on the computer,
via a remote control handset. For example, if running a media player or STB interface simulation
software, “sit-back” control from a sofa can provide a better experience.
Writing code to use the narrow band detector is quite similar to the wide-band, except that the detector
is turned ON for the duration of the period it is in use. uring this period, any number of input events
may be received, depending on how often the RCU buttons are pressed or what other IR noise may
appear as data.
EventHandler rcDetectorSignalInHandler = (s, ea) =>
{
var siea = ea as SignalEventArgs;
if (siea == null) return;
if (siea.Action == SignalEventAction.MODULATED_SIGNAL)
{
Console.WriteLine($"IR signal:\n{siea.ModulatedSignal}");
Console.WriteLine("Hit <RETURN> to stop RC signal input.");
}
};
// Hook up the incoming event handler just for this operation.
rrx.RCDetectorSignalIn += rcDetectorSignalInHandler;
// Start the RR-X listening until <RETURN> is hit.
rrx.RCDetectorEnabled = true;
Console.WriteLine("Hit <RETURN> to stop RC signal input.");
Console.ReadLine();
rrx.RCDetectorEnabled = false;
rrx.LearningSignalIn -= rcDetectorSignalInHandler;
Console.WriteLine("RC signal input terminated.\n");

6.5 Handling USB Plug Events
If using the RedRat-X via USB, then USB plug/unplug events can be used by the application to update
itself if devices are unplugged or new devices plugged in.
A USB unplug/plug handler is a typical C# event handler, which can be set up a number of ways, for
example an event handler method or using a lambda expression, as shown in the example below:
// Create local plug/unplug handler
EventHandler<UsbPlugHandler.UsbPlugHandlerEventArgs>
usbPlugHandler = ( sender, args ) =>
{
Console.WriteLine( "Plug event... " + args );
if ( args.plugEventType == UsbPlugHandler.DevicePlugEventEnum.Added )
{
// The plug event gives us the serial number of the device,
// so use this to find the RR-X that has just been plugged in.
var xLis = RRUtil.FindRedRats( LocationInfo.RedRatType.RedRatX_US )
.OfType<RedRatXUsbLocationInfo>();
var xLi = usbLis.FirstOrDefault(
li => li.SerialNumber == args.deviceSerialNumber );
Console.WriteLine( $"Plugged in device is '{xLi.Name}'" );
}
};
This is then wired up to the UsbPlugHandler object:
// Add plug/unplug handler
UsbPlugHandler.Instance.UsbPlugEvent += usbPlugHandler;
Console.WriteLine("Unplug + replug US RedRat-X and then hit <RETURN>");
Console.ReadLine();
// Remove plug handler
UsbPlugHandler.Instance.UsbPlugEvent -= usbPlugHandler;
While the code is waiting for the user to hit <RETURN>, the RedRat-X can be unplugged and re-plugged a
number of times to see the events as they are generated.
In a normal application, it is probably more useful for the plug/unplug handler to be setup at the start of
the application and remain active for its lifetime.
Other manuals for RedRat-X
1
Table of contents
Popular Control Unit manuals by other brands

Festo
Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation
JS Automation MPC3034A user manual

JAUDT
JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum
Spektrum Air Module System manual

BOC Edwards
BOC Edwards Q Series instruction manual

KHADAS
KHADAS BT Magic quick start

Etherma
Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations
PMFoundations Attenuverter Assembly guide

GEA
GEA VARIVENT Operating instruction

Walther Systemtechnik
Walther Systemtechnik VMS-05 Assembly instructions

Altronix
Altronix LINQ8PD Installation and programming manual