Reason RT411 User manual

RT411
Time Signal Distributor
User Manual
(Rev 1.1)
1

Contents
Preface 3
About the Document 3
Contact 4
Acronyms and Abbreviations 5
1 Getting Started 6
1.1 Description ............................................. 6
1.2 Unpacking .............................................. 6
1.3 External Indications ......................................... 7
2 Specifications 8
2.1 Electrical Input ........................................... 8
2.2 Optical Input ............................................ 8
2.3 Electrical Outputs .......................................... 8
2.4 Optical Outputs ........................................... 9
2.5 Power Supply ............................................ 9
2.6 Environment ............................................. 9
2.7 Weight and Dimensions ....................................... 10
3 Description 11
3.1 Features ............................................... 11
3.2 Front Panel Components ...................................... 11
3.3 Posterior Panel Components .................................... 12
4 Installation 13
4.1 Mounting .............................................. 13
4.2 Environment ............................................. 13
4.3 Power Supply ............................................ 13
4.3.1 AC Power Connection ................................... 14
4.3.2 DC Power connection ................................... 15
4.4 Powering Up ............................................ 15
2

4.5 Time Reference Inputs ....................................... 15
4.5.1 Selection of the Time Reference Input ........................... 16
4.5.2 Connection Diagrams of the Synchronism Inputs ..................... 17
4.6 Optical Outputs ........................................... 18
4.7 Electrical Outputs .......................................... 18
5 Maintenance 19
5.1 Troubleshooting ........................................... 19
5.1.1 POWER Indicator does not light up ............................. 19
5.1.2 ACT Indicator does not light up .............................. 19
5.2 Cleaning Instructions ........................................ 19
5.3 Returning a Unit .......................................... 19
3

Reason Tecnologia S.A. 4
Preface
c
2013 2011 Reason Tecnologia S.A., all rights reserved.
Products developed by Reason are continuously improved. The information this document contains reflects this
improvement, and for this reason it is subject to change without notice. Please make sure that this is latest
version of this document before proceeding. All specifications are subject to changes without prior notice.
Certification to the ISO 9001:2008 quality standard is an
example of this commitment. We encourage and appreci-
ate any feedback and will use it to improve our products
and services.
About the Document
This manual is intended to technically qualified personnel who has been trained or is knowledgeable in instru-
mentation and engineering fields.
This user manual is part of the scope of delivery and provides basic information for installation, configuration,
operation and maintenance of the equipment here described. In case additional information is needed, please
contact Reason at the addresses provided at the beginning of this document.
Document Id: rt411-manual-en
Revision: 1.1
According to:
Hardware Version 01
RT411 - User Manual [rt411-manual-en rev 1.1]

Contact
Reason Tecnologia S.A.
Rua Delminda Silveira, 855
88025-500 Florian´
opolis, SC
Brasil
Fone: (48) 2108-0300
Fax: (48) 2108-0310
http://www.reason.com.br
Reason International, Inc.
5900 Southwest Parkway, Suite 210
Austin, TX 78735
USA
Phone: (512) 615-0490
Fax: (512) 615-0491
http://www.reason-international.com
RT Measurement Technologies GmbH
Rudower Chaussee 29
12489 Berlin
Germany
Phone: +49 (0)30 57 70 63 32
http://www.rtgmbh.eu

Reason Tecnologia S.A. 6
Acronyms and Abbreviations
AC - Alternating Current;
BNC - Bayonet Neil Concelman connector;
DC - Direct Current;
DCF77 - DeutschlandLORAN-C Time synchronism protocol (Long Range Navigation - C) Frank-
furt 77 (77,5 kHz);
IEC - International Electrotechnical Commission;
IED - Intelligent Electronic Devices;
IRIG-B - Time synchronism protocol Inter Range Instrumentation Group (Rate Designation B);
PPS - Pulse-per-second;
PPX - Pulse-per-X s;
RT - Time recorder (Time synchronism equipment of Reason);
ST - Bayonet-lock connector;
RT411 - User Manual [rt411-manual-en rev 1.1]

Reason Tecnologia S.A. 7
1 Getting Started
1.1 Description
RT431 - Time Signal Distributor is an electrical signal multiplier. It multiplies IRIG-B demodulated, PPS or
any signal with a voltage between 0 and 5 V d.c., to frequencies up to 5 MHz, through electrical and optical
outputs, allowing the synchronization of IEDs. The equipment ensures time accuracy based on the accuracy of
the time reference source that is being used in the input.
The equipment has up to 10 electrical outputs with a 150 mA individual supply capacity and up to 10 optical
outputs for multimode fiber and ST connector.
It also has frontal indicators for monitoring the received synchronism signal and voltage of the primary supply.
1.2 Unpacking
Unpack the equipment carefully and make sure all the accessories and cables are put aside so they will not
be lost. Check the contents against the packing list that goes with the product. If any of the content listed is
missing, please contact Reason (see contact information at the beginning of this manual).
Examine the equipment for any shipping damage. If the equipment is damaged or fails to operate, notify the
shipping company without delay. Only the consignee (the person or company receiving the equipment) can file
a claim against the carrier for shipping damage.
We recommend you keep the original packing materials for eventual future transport.
RT411 - User Manual [rt411-manual-en rev 1.1]

Reason Tecnologia S.A. 8
1.3 External Indications
The specifications of the connections are shown on an external label above the equipment. The serial number
and part number are shown on a label fixed on the side of the equipment, as shown in Figure 1.
Figure 1: Location of Serial number, Part Numberand specifications of the connections
RT411 - User Manual [rt411-manual-en rev 1.1]

Reason Tecnologia S.A. 9
2 Specifications
2.1 Electrical Input
Table 2.1: Electrical Input Specifications
Signals IRIG-B00, PPX, DCF77, and signals with
a voltage between 0 and 5 V d.c.
Isolation Voltage 2500 V
High Level 1Between 4.5 V d.c. and 5 V d.c.
Low Level 2<0.2 V d.c.
Impedance >18 Ω
1Level above which the equipment recognizes input as activated;
2Level below which the equipment recognizes input as disabled.
2.2 Optical Input
Table 2.2: Optical Input Specifications
Signals IRIG-B00, PPX, DCF77, and signals with
a frequency up to 5 MHz
Connector ST
Wave Length 820 nm
Wave Length multimode 50 / 125 µm, 62.5 / 125 µm,
100 / 140 µm or 200 µm HCS
Sensibility −24 dBm
2.3 Electrical Outputs
Table 2.3: Electrical Outputs Specifications
Signals IRIG-B00, PPX, DCF77, and signals with
a voltage between 0 and 5 V d.c.
Connectors (10) 8 Screw
2 BNC
Current 150 mA
High Level 1Between 4.5 V d.c. and 5 V d.c.
Low Level 2<0.2 V d.c.
Impedance >18 Ω
1Level above which the equipment recognizes output as activated;
2Level below which the equipment recognizes output as disabled.
RT411 - User Manual [rt411-manual-en rev 1.1]

Reason Tecnologia S.A. 10
2.4 Optical Outputs
Table 2.4: Optical Outputs Specifications
Signals IRIG-B00, PPX, DCF77, and signals with
a frequency up to 5 MHz
Connector ST
Wave Length 820 nm
Fiber Type multimode 50 / 125 µm, 62.5 / 125 µm,
100 / 140 µm or 200 µm HCS
Transmission Power −17.8dBm (50 / 125 µm)
−14.0dBm (62.5 / 125 µm)
−8.5dBm (100 / 140 µm)
−5.7dBm (200 µm HCS)
We recommend the use of optical-fiber cables with a maximum length of 2 Km.
2.5 Power Supply
Table 2.5: Power Supply Specifications
Operating rated voltage 100–250 V d.c., 110–240 V a.c.
Operating voltage range 80–275 V d.c., 88–264 V a.c.
Frequency 50/60 Hz ±3 Hz
Consumption 15 W
2.6 Environment
Table 2.6: Environment Specifications
Recommended temperature range +5 ...+55 ◦C (+41 ...+131 ◦F )
Tested temperature range −25 ...+70 ◦C (+13 ...+158 ◦F )
Enclosure protection IP40
Relative humidity 5 . . . 95%, noncondensing
RT411 - User Manual [rt411-manual-en rev 1.1]
Table of contents
Other Reason Multiplexer manuals
Popular Multiplexer manuals by other brands

ADTRAN
ADTRAN Frameport 768 Specifications

Elo TouchSystems
Elo TouchSystems E247 Operation manual

Paradyne
Paradyne Hotwire 8786 installation instructions

RFL Electronics
RFL Electronics 9508D UCC instruction manual

Miranda
Miranda AMX-101i Guide to installation and operation

ShipModul
ShipModul MiniPlex-AIX NMEA-0183 manual