Viper Pro Do’s and Don’ts
Do have the Viper Pro serial number and firmware revision available when calling
for technical assistance. It is best if the user is in the machine and in front of the
Viper Pro when calling for tech support.
Do review the manual in its entirety before operating Viper Pro.
Do power the DGPS receiver and the Raven console or CANBus system before
powering Viper Pro.
Don’t jump start or weld on any part of the vehicle with the field computer
connected. To prevent damage to the field computer, disconnect the main and
auxiliary cable connectors on the back of the field computer.
Don’t turn Viper Pro off when in a job without properly closing the job first. If the
field computer loses power when in a job, part of the information within the job files
will not be saved and the associated files may become corrupt.
Don’t use sharp objects or harsh chemicals on the field computer touch screen
as they may damage the display.
Don’t use the USB ports to charge mobile devices such as phones, tablets, or
mp3 players.
Basic Startup
1. Touch the power button to turn on the
Viper Pro field computer.
2. Allow the Viper Pro field computer to
power up.
3. If the Program Selection Menu displays,
touch the Sprayer/Spreader option to
begin the application management
system.
Note: Refer to the Installation and
Operation Manual for information
about the other options available in
the Program Selection Menu.
4. If the Viper Pro is configured as the
CANbus controller, verify that the appropriate
product nodes or control channels are displayed on
the CAN Initialization Results screen and touch the
Start Viper button to launch the Viper Pro precision
application management system.
If no CAN nodes are detected on the CANbus when
the Viper Pro is powered on, touch the Retry CAN
Init button. If you still have CAN issues, see the
Viper Pro Installation & Operation Manual for more
information.

2
Backlight Adjustment
1. Touch Menu, About, Adjust Brightness.
2. Touch the display mode button to toggle the
day or night modes for the Viper Pro
display.
3. Touch to increase screen intensity or
touch to decrease screen intensity.
Main Screen Areas
See the screens below and the corresponding numbered sections for a
description of each screen area.
1. Profile - The machine profile contains configuration settings for specific
vehicles, when created by the user.
2. Current Heading - The current heading of the vehicle in compass degrees.
3. Speed - The current speed of the vehicle (CAN or GPS).
4. Map Area - The map area displays information based on the selected tab.
Touch the tabs along the right side of the Viper Pro display to view application
information, maps, or guidance information.
5. Tabs - Used to access available features, functions and screen displays during
a job. The Main tab is available only if a job is not in progress.
6. Display Data and Alarm Information - Touch the ‘DD’ icon to view the
status of CAN Tally Registers. Touch the ‘DD’ icon again to hide the data.
If an active alarm condition is detected, the ‘DD’ icon will be replaced with a red
alarm icon. Touch this icon to display alarm information. Information for new
alarms will be displayed automatically.
Note: Refer to the “CAN Controller Status Screen” section on page 4 for
additional alarm display information.
Display
Mode
or
12
3
5
4
8
1110 13
12
7
6
9
12
3
5
4
8
11 10 13
12
7
6
9

3
7. Wireless Status - If a Slingshot Field Hub™ is connected to the Viper Pro
field computer, the status of wireless communications is accessible by touching
the wireless communication status indicator.
8. Booms - The Booms area displays the status of boom or implement sections.
A section display character will display green when on, grey when off. Touch in
this area to configure the optional AccuBoom system.
Note: Boom sections controlled by the optional AccuBoom system will display
with a blue background.
9. Application Rates - Target rate (RT) and actual rate (RA).
Touch in this area to set or change rates (available for CAN or serial systems
only).
10.GPS Status Indicator- Status of DGPS messages and the current source
of GPS corrections are displayed in this area. Touch this area for additional
GPS information.
11.Product Control Status - Product Control Status of a Raven serial
console or a Raven CAN system displays in this area. Touch this area to view or
modify Product Control settings.
12.SmarTrax Status Display - If an optional SmarTrax system is installed
with the Viper Pro, this area displays the status of SmarTrax system.
13.AutoBoom Status Display - If an optional Glide Series AutoBoom
system is installed with the Viper Pro system, this area displays the status of
AutoBoom system. Touch this area to enable/disable or configure AutoBoom
system.
Map Tools
Map
Symbols Description
When the Cursor Lock icon is active, Viper will automatically pan
the display to keep the vehicle indicator on screen. Select this
mode when running a job.
The Information icon is available on the Main tab when a job is
not in progress, or on the Scout tab during an active job. Select this
icon and touch the map area to view map information.
The Prescription icon is only available on the Rx tab (if a
prescription map had been previously loaded) or the Cov tab.
The Pan icon is used to manually pan the map information up/
down or left/right.
Touch the Zoom Out icon and then select the map area to view a
larger area on the map.
Touch the Zoom In icon and then select the map area to view a
more detailed area on the map.

4
Status Symbols
CAN Controller Status Screen
See the screen and the corresponding
sections for a description of the CAN
Controller Status screen areas.
Note: The CAN Controller Status screen
shown above is only displayed if the
Viper Pro is configured as the
CANbus control console. Review
the Viper Pro Installation and
Operation Manual for information
on configuring the field computer.
1. Boom Cals Area - Current booms
that have been configured. Touch in this
area to assign booms to products using
the Boom Select screen.
2. Miscellaneous Area - Various
system settings and actual system
readouts. Touch in this area to change
the displayed settings.
3. Feature Settings Area - The upper
portion of the Feature Settings area displays the selected product node or
control channel. Use the drop down selection box to select other available
control channels and display the programmed channel settings.The lower
portion of the Feature Settings area displays the current alarm and feature
setting selections. Touch in this area to access the feature and alarm settings.
The Zoom Extents icon allows you to quickly bring all map
information back onto the display.
Status
Symbols Description
Thumbs Up:
System is normal and all operating conditions are met.
Caution:
There is a system alert. It is recommended to investigatethe cause
of the condition and correct it.
Red ‘X’:
The system has encountered a critical error and requires
immediate attention. The condition must be corrected before
proceeding with application.
Map
Symbols Description
12
3
5
4
8
7
6

5
4. Product Control Settings Area - Displays the current product control
settings for the selected product node or control channel. Touch in this area to
configure product control for the selected node or channel.
5. Pressure Area - Dual pressure readouts for two different systems. Touch in
this area to calibrate pressure readouts.
6. Application Area - Valve and application types used to apply the product.
Touch in this area to select a different valve type and/or application type.
7. Tally Registers - Touch this button to access the tally registers. Also
displays the distance traveled by the vehicle. All values except the total volume
and total area may be reset to zero while in a job.
8. Current Alarms - Touch this button to view any current system alarms.
Profiles
Saving a Profile
1. Select Menu, then Setup, Local, Profile and Save Profile.
2. Use the on-screen keyboard to enter a
Profile Name and touch OK.

6
Loading a Saved Profile
1. Select Menu, then Setup, Local, Profile and Load Profile.
2. Select a profile from the list and touch OK.
3. Touch the OK button on the Load Profile prompt. The Shutdown Viper prompt
will be displayed.
4. Select the Exit to Menu button and select the appropriate option to restart the
Viper Pro application management system.

7
Setting Application Rates
1. Touch the Application Rates Area.
2. Touch the desired Node or Channel to set/change.
3. Enter Target Rate. Touch Next to change other Nodes or OK to save changes
and close.
Note: Application Rates may only be modified on the Viper Pro if the field
computer is set as the CANbus controller. Product density and spreader
constant may also be modified when controlling a granular application
system.
4. Touch the Default Rate button to set a default rate for each product used with a
prescription map. The default rate will be applied to areas without prescription
information (i.e. outside of the prescription map area).
or

8
Starting a New AgX Job
1. Select Menu, Start Job, then New AgX Job.
2. Select from the available grower, farm and field lists to locate the prepopulated
job information for the next job.

9
3. Touch the Next button.
4. Touch an available control channel and select a recommendation from the list to
assign prepopulated job information to the selected control channel.
Note: While recommendations are not required, product control channels
selected on this screen should have a recommendation assigned before
the job is started.
A target rate may be entered for channels used to control pump, fan, or
spinner speeds as necessary after the job is started. Do not select control
channels for these functions during the job setup process.
To deselect a channel, touch a selected channel again to remove the channel
from the job setup process. Any deselected channels will not be available
during the active job.
5. Touch the Default Rate button and enter the default rate for each control
channel outside of the prepopulated prescription map.
6. A Conversion Factor may be entered to adjust rate zones within the
prepopulated prescription map.
7. Touch Next and enter the name for the job, select the guidance pattern to use
during the job and enable the AccuBoom feature if applicable.
8. Touch the OK button to begin the job.
Other manuals for Viper Pro
2
Table of contents
Other Raven GPS manuals

Raven
Raven 210LB Manual instruction

Raven
Raven RS1 User manual

Raven
Raven Phoenix 300 User manual

Raven
Raven ASTERX4 Technical manual

Raven
Raven RS1 Use and care manual

Raven
Raven Envizio Pro User manual

Raven
Raven Slingshot Field Hub 2.0 User manual

Raven
Raven RS1 User manual

Raven
Raven XP User manual

Raven
Raven SmarTrax User manual

Raven
Raven SmarTrax User manual

Raven
Raven RS1 User manual

Raven
Raven INVICTA 115 Manual

Raven
Raven CRX User manual

Raven
Raven Viper 4 Technical manual

Raven
Raven Cruizer II Manual

Raven
Raven Phoenix 50 Administrator Guide

Raven
Raven RTH-10 Parts list manual

Raven
Raven SmartRow User manual

Raven
Raven RTV-40 User manual