R&S SZU100A User manual

R&S®SZU100A
IQ Upconverter
58.32-64.8 GHz
Manual
Manual
Version 04
1425306102
(>INË2)

This document describes the R&S®SZU100A, stock. no. 1425.3003.02 and its
options:
●R&S®SZU-B1066 (1425.3110.02)
© 2019 Rohde & Schwarz GmbH & Co. KG
Mühldorfstr. 15, 81671 München, Germany
Phone: +49 89 41 29 - 0
Fax: +49 89 41 29 12 164
Email: [email protected]
Internet: www.rohde-schwarz.com
Subject to change – Data without tolerance limits is not binding.
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.
Trade names are trademarks of the owners.
1425.3061.02 | Version 04 | R&S®SZU100A
The following abbreviations are used throughout this manual: R&S®SZU100A is abbreviated as R&S SZU,
the R&S®SMW200A is abbreviated as R&S SMW, the R&S®ZCTW is abbreviated as R&S ZCTW.

Contents
R&S®SZU100A
3Manual 1425.3061.02 ─ 04
Contents
1 Safety Information................................................................. 5
2 Documentation Overview......................................................6
3 About This Manual.................................................................7
4 Welcome to the R&S SZU..................................................... 8
5 Preparing for Use.................................................................10
5.1 Unpacking and Checking the R&S SZU............................................10
5.2 Putting into Operation........................................................................ 11
5.3 Adjusting the Feet...............................................................................12
6 Instrument Tour................................................................... 13
6.1 Front View............................................................................................13
6.2 Rear View.............................................................................................14
6.2.1 Power Supply Connector...................................................................... 15
6.2.2 IQ Input Connectors..............................................................................16
6.2.3 Status LED............................................................................................16
6.2.4 USB Interface........................................................................................17
6.2.5 LO In/Out Connectors........................................................................... 17
6.2.6 Trigger Input/Output Connector............................................................ 17
7 Startup.................................................................................. 18
7.1 System Requirements........................................................................ 19
7.2 Measurement Setup............................................................................20
7.3 Starting Up...........................................................................................22
7.4 Running Internal Adjustments...........................................................30
7.5 Behavior of the R&S SMW When Working with the R&S SZU........ 32

Contents
R&S®SZU100A
4Manual 1425.3061.02 ─ 04
8 Remote Control of the R&S SZU........................................ 36
Glossary: List of Frequently Used Terms and Abbrevia-
tions...................................................................................... 38
Index..................................................................................... 40

Safety Information
R&S®SZU100A
5Manual 1425.3061.02 ─ 04
1 Safety Information
The product documentation helps you use the R&S SZU safely and efficiently.
Follow the instructions provided here and in the printed "Basic Safety Instruc-
tions". Keep the product documentation nearby and offer it to other users.
Intended use
The R&S SZU is intended for the development, production and verification of
electronic components and devices in industrial, administrative, and laboratory
environments. Use the R&S SZU only for its designated purpose. Observe the
operating conditions and performance limits stated in the data sheet.
Where do I find safety information?
Safety information is part of the product documentation. It warns you about the
potential dangers and gives instructions how to prevent personal injuries or dam-
age caused by dangerous situations. Safety information is provided as follows:
●The printed "Basic Safety Instructions" provide safety information in many lan-
guages and are delivered with the R&S SZU.
●Throughout the documentation, safety instructions are provided when you
need to take care during setup or operation.

Documentation Overview
R&S®SZU100A
6Manual 1425.3061.02 ─ 04
2 Documentation Overview
This section provides an overview of the R&S SZU user documentation. You find
it on the product page of the R&S SZU, see www.rohde-schwarz.com/manual/
szu100a. The User Manual of the R&S SMW is provided at www.rohde-
schwarz.com/product/SMW200A/User Manual.
The user documentation for the R&S SZU consists of the following parts:
Manual
Introduces the R&S SZU and describes how to set up and start working with the
product. Includes basic operation and general information, e.g. safety instruc-
tions, etc. A printed version is delivered with the instrument.
Online help
The online help offers quick, context-sensitive access to the complete information
for the base unit and the software options directly on the R&S SMW.
General safety instructions
The brochure delivered with the instrument contains basic safety instructions and
operating conditions and further important information.
Data sheet and brochure
The data sheet contains the technical specifications of the R&S SZU. It also lists
the options and their order numbers and optional accessories.
A brochure provides an overview of the instrument and deals with the specific
characteristics.
See www.rohde-schwarz.com/brochure-datasheet/szu100a.
Release notes and open source acknowledgment (OSA)
The release notes list new features, improvements and known issues of the cur-
rent firmware version, and describe the firmware installation.
The open source acknowledgment document provides verbatim license texts of
the used open source software.

About This Manual
R&S®SZU100A
7Manual 1425.3061.02 ─ 04
3 About This Manual
This user manual which you have received as printed book with your instrument,
provides all the specific information about the R&S SZU. The instrument functions
and settings concerning the R&S SMW are described in the main R&S SMW user
manual.
The main focus is on the tasks required for setting up the measurement system.
The following topics are included:
●Welcome to the R&S SZU IQ Upconverter
Introduction to and getting familiar with the instrument.
●Preparing for use
Basic steps to be taken when setting up the R&S SZU IQ Upconverter for the
first time.
●Startup
Description on how to take the R&S SZU IQ Upconverter into operation.
●Remote control
Remote control commands related to the R&S SZU, see the R&S SMW user
manual.
●Glossary
Alphabetical list of frequently used terms and abbreviations

Welcome to the R&S SZU
R&S®SZU100A
8Manual 1425.3061.02 ─ 04
4 Welcome to the R&S SZU
The Rohde & Schwarz R&S SZU is an IQ upconverter designed for the 60 GHz
frequency band. These frequencies are used in modern high-performance wire-
less communication standards, e.g. IEEE802.11 ad. Operating in the 60 GHz fre-
quency band enables devices to communicate at multi-gigabit speed, with data
transfer rates of several Gbit/s.
Key features
The R&S SZU IQ Upconverter features:
●Compact broadband upconverter providing 57 GHz to 66 GHz frequency
●Power output of at least 5 dBm for over the air (OTA) RF measurements and
tests
●Adjustable output power in the range +5 dBm to -80 dBm, with integrated level
detector
●RF output signal at the waveguide port
●Support of common mountable test port adapters
●High-level stability and harmonic suppression
●Compatible to all R&S SMW frequency options
●Support of the R&S SMW output level user correction
●Fully calibrated at the waveguide port
●Control via user interface of the R&S SMW
●Small size, easy usage, and operation in any position possible
About the R&S SZU IQ Upconverter
The R&S SZU generates a vector-modulated signal by converting the baseband
signal to the output frequency range of 58.32 GHz to 64.8 GHz (center fre-
quency).
The R&S SZU receives the differential or single ended baseband signals (I/Q),
and an LO signal in the range of 1.944 GHz to 2.16 GHz from the R&S SMW.
The USB host interface is the communication port of the R&S SZU to the
R&S SMW. As external instrument, the R&S SZU is configured in the "System
Configuration" dialog of the R&S SMW, and indicated by a symbol in the GUI.
Once connected, the R&S SMW reads the calibration data of the R&S SZU, and

Welcome to the R&S SZU
R&S®SZU100A
9Manual 1425.3061.02 ─ 04
adjusts the frequency and level values to the output values of this downstream
instrument.
Thus the R&S SMW controls the R&S SZU almost entirely. You only need to
select single ended or differential mode for the baseband connection. It is recom-
mended that you work in differential mode due to better common mode noise
suppression over the single ended connection. When you work with two
R&S SZUs on one R&S SMW, you must work in single ended mode.
The setting parameters in the R&S SMW remain the same.

Preparing for Use
R&S®SZU100A
10Manual 1425.3061.02 ─ 04
5 Preparing for Use
This section explains how to take an R&S SZU IQ Upconverter into operation. It
includes the controls and connectors of the R&S SZU, and provides all the infor-
mation necessary for connection.
For information on the equipment required for a basic test setup, see Chapter 7.1,
"System Requirements", on page 19.
5.1 Unpacking and Checking the R&S SZU
To remove the instrument from its packaging and to check the equipment for com-
pleteness, proceed as follows:
1. Unpack the R&S SZU and the other contents of the shipping container.
2. Check the equipment for completeness using the delivery list.
3. Remove the protective cap from the waveguide port at the front of the
R&S SZU. Inspect the instrument carefully, to make sure that it has no dam-
age from shipment.
If there is any damage, immediately contact the freight forwarder, who has
delivered the instrument.
Packaging material
It is recommended that you retain the original packaging material. If the
R&S SZU needs to be transported or shipped later, you can use the mate-
rial to prevent control elements and connectors from being damaged.
Equipment returned or sent in for repair must be packed in an appropriate
packaging, if the original packaging is no longer available.
Also use the packaging material for storage of the instrument and the
accessories.
Unpacking and Checking the R&S SZU
Table of contents
Other R&S Media Converter manuals