Quasar SmartCell 212 User manual

Thank you for purchasing “SmartCell 212 /112” product.
Quasar Communication Systems Ltd. and its distributors assume no
responsibility for any damage or loss resulting from the use of its products or
this user manual. Quasar Communication Systems Ltd and its distributors
assume no responsibility for any loss or claims by third parties, which may
arise through the use of its products.
Registration and Type Approval
Smartcell 212 /112 carries CE Certification, Australia AS/NZS3548
Corporate contacts
E-mail: [email protected]
Web address: www.quasar.biz
© Quasar Communication Systems Ltd. All rights reserved. Quasar, the
Quasar Logo, CelluLink and CellBox are registered trademarks of Quasar
Communication Systems Ltd. Other product and brand names may be
trademarks or registered trademarks of their respective owners.
September 2003


2
1. Introduction
1.1 Overview
The SmartCell 212 and 112 gateway enables direct connection of an
organization's internal telephony system to commercial cellular networks via
an already existing Private Branch Exchange (PBX) system.
The SmartCell 212 has a standard ISDN BRI “S0” interface on the Line side
and connects with 2 channels to any GSM cellular network to create a
cellular gateway. The SmartCell 112 is a single channel gateway. SmartCell
212/112 operates at 900MHz/1800MHz. The 212-1900 and 112-1900
models operate at 900MHz/1900MHz.
1.2 Packing List
for 212
Item Description Qty
1 SmartCell 212 unit 1
2 Power Supply 1
3 ISDN S Interface Cable (straight) 1
4 SYNC IN Cable (straight) 1
5 Antenna 2
6 Bag with Screws and Dowel Pins 1
7 Bracket 2
8 Installation Guide 1
for 112
Same list apart of one antenna and one bracket provided.

SmartCell 212/112
3
Cables
Power Cable
ISDN Interface Cable
SYNC IN Cable
Antenna
2 Bags with Screws
& Dowel pins
SmartCell 212/112 unit
Drill Template

4
2. Safety Precautions
Main voltages are present at specific points in this equipment. Some of the
parts can also have high operating temperatures. Non-observance of these
conditions and safety instructions can result in personal injury or in property
damage.
The Smartcell 212 system complies with the standard IGC 950. All
connected equipment must comply with the applicable safety standards:
EN 55022
IEC 1801-2/91
IEC 801-3
IEC 801-4
To avoid injury and prevent equipment damage, observe the following safety
precautions:
Do not ship equipment unless it is properly packed in its original wrapping
and shipping containers.
Do not connect the 212 or 112 to any power supply other than the one
provided with it.
Equipment service and maintenance should be done only by qualified
personnel.

SmartCell 212/112
5
3. Product Description
3.1 Technical Specifications*
Power supply
Supply voltage (secondary) 12V DC
Supply current 2 A max.
Operating temperature 0 ºC to 40 ºC
Standards Full CE
ISDN specifications
Line interface BRI – S/T point reference (indoor only),
Type NT or partial TE.
Protocol Euro ISDN.
Connector type RJ-45
Data Port Specifications
Interface port/Connector type RS232
Protocol AT command compatible
Dial tone 400 Hz ± 1%
GSM channel specifications
Cellular interface Wavecom GSM module
Networks supported Dual band EGSM 900/1800 MHz for 212
or 900/1900 for 212-1900
Standards Full type approval according to GSM phase 2+
specifications.
Antenna
Antenna gain Antenna gain – 2.5 0dB
Antenna connector FME or SMA
*Specifications are subject to changes without notice

6
3.2 LED Indications
Led Description Operation
Power Indicates the
status of the
power
connection.
On–the SmartCell 112/212 is
powered on.
Off–the SmartCell 112/212 is
powered off.
Status 1 Indicates the
SmartCell
212
operational
status of
channel 1
Off–the channel is idle and no
calls are being handled.
On–the channel is handling a
call.
Slow blinking–the SmartCell
112/212 is initialising
following power up or is
being programmed.
Fast blinking–an error has
occurred in the PIN code
entry and the outgoing call
cannot be completed. The
PIN code must be disabled or
the default PIN code 1234
must be entered.
RCPT.LVL 1
(Reception Level
Channel 1)
Indicates the
reception level
of the GSM
channel 1
Green -High reception.
Orange -Medium reception.
Red-Low reception
Off -Very low reception or no
reception at all.

SmartCell 212/112
7
Led Description Operation
STATUS 2 Indicates the
SmartCell
212
operational
status of
channel 2.
Off–the channel is idle and no
calls are being handled.
On–the channel is handling a
call.
Slow blinking–the SmartCell
112/212 is initialising
following power up or is
being programmed.
Fast blinking–an error has
occurred in the PIN code
entry and the outgoing call
cannot be completed. The
PIN code must be disabled or
the default PIN code 1234
must be entered.
RCPT.LVL 2
(Reception Level
Channel 2)
Indicates the
reception
level of the
GSM
channel 2
Green -High reception.
Orange -Medium reception.
Red-Low reception.
Off -Very low reception or no
reception at all.
ISDN Ready ISDN NT
interface
indicate the
ISDN NT
port physical
layer status.
Off–No ISDN NT Layer 1
connection.
On–ISDN NT layer 1
connection established.
Sync/ TE ISDN TE
interface
indicates the
TE physical
layer status or
the Sync IN
status.
Off–No ISDN TE Layer 1
connection or no Sync IN.
On–ISDN TE layer 1
connection established or
Sync IN is active.

8
4. SmartCell 212/112 Installation
4.1 Installation Instructions
4.1.1 Locate template on the wall and mark screw location
4.1.2 Bore 3 holes.

SmartCell 212/112
9
4.1.3 Insert 3 dowel pins.
4.1.4 Tighten the two upper screws. Leave a gap of 3mm minimum between
the screw head and the wall.
4.1.5 Mount the SmartCell 212/112 on the 2 screws.
This manual suits for next models
1
Table of contents
Popular Gateway manuals by other brands

LST
LST M500RFE-AS Specification sheet

Kinnex
Kinnex Media Gateway quick start guide

2N Telekomunikace
2N Telekomunikace 2N StarGate user manual

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Original instructions

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE user guide

Telsey
Telsey CPVA 500 - SIP Technical manual