QEES 311-AQW-A1 User manual

EN
Quick Guide
QEES RETO Shell Switch Standard
QEES RETO Shell Dimmer Standard
QEES RETO Shell Switch Plus
QEES RETO Shell Dimmer Plus
Download complete manual at
www.qees.eu/en/support/retoshell
QEES product references covered by this Quick Guide:
311-AQW-A1
311-AQW-A2
311-BQW-A1
311-BQW-A2
311-GQW-A1
311-GQW-A2
311-HQW-A1
311-HQW-A2

Going Green with QEES
Congratulations on your new QEES RETO Shell. You can now
wirelessly control your appliances or lighting equipment
while metering their power consumption.*
All QEES Z-Wave®products are Z-Wave-certied. This
ensures interoperability with Z-Wave-certied products from
other manufacturers.
Read more on how your QEES product can help you go
green at www.qees.eu.
*metering available for Plus edition devices only
Required Tools
To install your QEES RETO Shell you will need the following
tools:
Phillips blade
screwdriver
Cable stripper/cutter
Power Plug QEES RETO Shell Connected Product

This guide describes the
installation of RETO Shell
products.
Please note that you may
connect wires in two differ-
ent ways: pass-through or
loop-back as illustrated by
the gure above.
RETO Shell Dimmer is a
UNI dimmer capable of
gradually adjusting light
intensity in many loads,
such as: Energy-saving,
LED, halogen and incan-
descent light bulbs.
RETO Shell Switch can
control various electrical
appliances. RETO Shell
Dimmer, however, is to be
connected only to dim-
mable loads.
During installation both
your QEES product and the
appliance to be controlled
must be disconnected from
mains power.
1
Installation
1 2 3

Snip your appliance’s
power cable where you
want your RETO Shell
placed. Strip the wires as
illustrated in gure 4.
Take off the back cover of
your RETO Shell by remov-
ing the four screws shown
in gure 5.
If your appliance has
a ground/earth wire,
connect it to the terminal
block marked (the
ground/earth wire in the
EU is typically green/yel-
low, US typically green).
The stripped wires from
your appliance’s cables
are to be connected to
terminals L and N. The
wires to the appliance go
into the terminal block
marked OUT.
50 mm
5 mm
Cable Relief
Terminal Blocks
4 5 6 7

The cables are secured
using cable reliefs as
shown in gure 8. When
using loop-back wiring,
both cables are secured by
the same cable relief.
When using pass-through
wiring, the plastic tab
shown in gure 9 must be
broken off the back cover.
A short press on the device
will toggle the controlled
appliance - only when the
device is completely initial-
ized. Refer to the online
manual for additional
information.
Remount back cover. The
device is now ready for
use. Connect it to power
and to a plugged-in load
and it will light blue as it
attempts to join a Z-Wave
network.
IN
OUT
10 118 9

The following guide de-
scribes how to set up and
control your QEES RETO
Shell with QEES MyKey.
Should you have another
Z-Wave controller, please
consult its manual for
conguration.
Press three times quickly
on the button you want to
control the product with –
the LED ashes blue.
Then press your RETO Shell
product three times quickly
– the LED ashes blue and
it begins linking.
After successful linking
between MyKey and your
RETO Shell, both LEDs
will light green for two
seconds.
2
Conguration
1 2 3

You can control several
products from the same
button on the MyKey. In
order to do so, repeat
conguration steps 1-3.
Your product can now be
controlled by your MyKey.
A short button press will
toggle it; a long press will
dim lights up or down
(applies only to QEES
Dimmers).
Repeat conguration steps
1-3 to congure more
products on your MyKey’s
other buttons.
4 5 6
You can delete a link to a
product from a button on
MyKey. Refer to the online
manual for a complete
description on how to
perform network actions.
7

You can restore the default
settings by pressing four
times quickly - the LED lights
blue. Then press three times
quickly - the LED lights red.
Then hold the button until
the device lights green.
8
You can learn more about
advanced features like
the timer function, watch
instructional videos and
get conguration advice
for your products at
www.qees.eu/en/video.
9
Scan the QR code to learn
much more about the pos-
sibilities that your product
has to offer. Download
the product manual at
www.qees.eu/en/support/
retoshell.
10

3
Technical
specications
QEES RETO Shell Switch:
Supply Voltage: 100-240 VAC - 50-60 HZ
Standby power: 0,3W
Rated power: Max. 16 A resistive load, 3680 W/230 VAC When using
other type of loads, please refer to the online manual
Protection rating: IP 20 - Only for indoor use.
Rated current: Max. 16 A
Other: For more information, please refer to the online manual.
QEES RETO Shell Dimmer:
Supply voltage: 100-240 VAC - 50-60 HZ
Standby power: 0,4W
Rated power: 400 W/230 VAC - 190W/110VAC When using other type
of loads, please refer to the online manual.
Protection rating: IP 20 - Only for indoor use.
Rated current: Max. 1.66 A
Other: For more information, please refer to the online manual.
This product is made in China and meets the requirements for
CE marking in accordance with directive 89/336/EEC, 99/05/
EEC, 2006/95/EC and 2011/65/EU.
WEEE
The Waste Electrical and Electronic Equipment Directive
.
The product is marked with the crossed out wheelie bin, and
electronic equipment must not be disposed with other house-
hold waste, but must be collected separately.
This manual suits for next models
7
Table of contents