PX 229
PxAqua 3
SH/SP
R

CONTENTS
1. General description...................................................................................................
2. Safety conditions.......................................................................................................
3. Information about the lamp version...........................................................................
4. Lamp description.......................................................................................................
5. Connections scheme.................................................................................................
6. Dimensions................................................................................................................
7. Technical specification...............................................................................................
8. Declaration of conformity...........................................................................................
3
3
5
6
7
9
9
10
Manufacturer reserves the right to make modifications in order to improve device
operation.
PXM Marek Żupnik limited partnership
ul. Przemysłowa 12
30-701 Kraków, Poland
tel.: +48 12 626 46 92
fax: +48 12 626 46 94
E-mail: [email protected]
Internet: www.pxm.pl
Rev 1.5

3
Underwater lamp LED LAMP PX 229 with an adjustable handle has built-in 3 LEDs.
The PX 229 lamp is designed for both underwater and open air installations, which require high
brightness lighting. In underwater sollutions the lamp can be powered with 700mA current and
reach 3x3Watt of power (in open air sollutions it has to work with 350mA power supply and reach
3x1Watt).
When connected to an external controller it allows to obtain a full spectrum of 16 million colors (in
theory). Use of high-quality Luxeon® Rebel LEDs provide bright light with low power
consumption.
When purchasing lamps customer can choose the appropriate scattering angle lenses and color
LEDs to be installed. This allows to adapt the device to the specific conditions.
The casing is made of stainless steel, which protects against harmful external conditions.
A specially made adjustable handle simplifies installation. For underwater instalations we provide
with product stailess steel tube for flush-mounting.
1. General description
2. Safety conditions
Caution! Before installing, connecting and using
the lamp you have to absolutely read this document.
The following symbols are used to underline important information on security conditions on
the product and in this manual.
Danger!
Risk of loss of life
and health.
Warning!
Fire hazard.
Warning!
LED light
emission.
The risk of eye
damage.
Warning!
The risk of burns.
Warning!
Read the
instruction
manual.
ESD Protection!
Read the
instruction
manual.
Caution!
Do not look at the LEDs at a shorter distance than 1.8m from the front surface
of the tube without proper eye protection. LEDs can cause damage or eye
irritation.Do not look at the light source directly through any optical
instruments, which focus the light rays.

The PX229 LED lamp is powered with 3x350 or 3x700 mA current and safe voltage up to 48 V, but
during the installation and use the following rules must be strictly observed:
1. Installation, particularly power connection, should be performed by a person holding the
appropriate qualifications, according to this manual.
2. The lamp can be connected only to a current source of a magnitude 3x350 or 3x700 mA
(3x700mA only in underwater installations) according to described in paragraph 5 conditions.
3. All wires must be protected against mechanical and thermal damage.
4. In case of damaging any conductor, it should be replaced with a conductor of the same
technical parameters.
5. All repairs can be performed only with power supply disconnected.
6. Wait 20 minutes after turning the lamp off before attempting to do any maintenance.
7. Prior to any maintenance of the module inside of the lamp, discharge any static electricity that
may damage the LEDs, by touching the grounded elements. Also remember not to use
nearby the LED module any soldering transformer.
8. All flammable materials (e.g. textiles, wood, paper, etc.) should be kept in a safe distance of at
least 0.3 m from the outer surface of the housing.
9. Do not connect the power supply to a lamp with visible damage.
10. It is essential to protect the module located in the lamp PX229 from contact with water and
other fluids.
11. All sudden shocks, particularly dropping, should be avoided.
12. Do not use in open air with temperatures higher than + 40°C.
13. The device can be installed and used in accordance with the conditions contained in this
manual, as well as applicable standards and regulations not listed in this document.
4
In case of improper usage of the product it may cause a risk of serious injury or
death because of the threat of fire.
While working at an ambient temperature of 25°C housing unit can heat up to
65°C. Because of the danger of burns, avoid direct contact with the casing.
Keep ESD protection because the module and installed LEDs may be damaged
by static electricity generated in equipment, people, tools and other insulators
or semiconductors.

The PX 229 lamp is available in several versions differing in angle of used lenses.
Below is a description of the PX229 models designations and their explanation.
PX 229 - XX - YYY - ZZ
XX-lens angle.
Available values:
o
10 - 10
o
25 - 25
o
45 - 45
YYY- LEDs colors.
Available colours:
W - warm white
N - neutral white
C - cold white
R - red
G - green
B - blue
A - amber
ZZ - casing version.
Dostępne wersje:
SH - with a handle
SF - with steel pipe
When ordering, select the lamp LEDs color and beam angle of lenses to be placed in the device
Example of lamp marking:
PX 229 - 25 - RGB - SH
Casing version:
Waterproof IP68.
Casing is in accordance with IP68 standard, allows to use the device underwater in
applications such as fountains, pools, and in places exposed to adverse weather conditions.
3. Information about the lamp version
LEDs color: red, green, blue
o
25 lenses
Lamp version
5
Casing version: with a handle

4. Description
6
3 LEDs
1
2
Handle
3 holes for fastening screws
3
4
2 screws with washer fastening the holder and casing together (allows you
to adjust the angle the lamp in the vertical plane)
4
2
3
1

The RGB version of lamp is connected via 6-strand cable, e.g. shown in the figures below.
5. Connections scheme
4
1
2
6
2
3
5
RED + (red)
RED - (
)
red with black
stripe
1
2
GREEN - (green
)
with
black stripe
GREEN + (green)
3
BLUE - (
)
blue with black
stripe
BLUE + ( )blue
5
6
4
4
1
2
6
2
3
5
RED + (red)
RED - (white)
1
2
GREEN - (black)
GREEN + (green)
3
BLUE - ( )yellow
BLUE + (blue)
5
6
4
7
Example of connection the PX229 lamp to the LED driver PX 305.
Wires should be connected with an appropriate sequence of colors.
!!! Lamps have to be connected only in series !!!
a) RGB lamp connection
to subsequent
modules
Max number of lamp that can be
connected differs from chosen
LED driver.
Tables visible on next page show
correct quantities
driver LED
RED +
RED -
GREEN +GREEN -
BLUE +BLUE -
RED -
GREEN -
BLUE -
RED +
GREEN +
BLUE +

8
b) Monochromatic lamps connection
PY 410
current power supply
DC OUT
AC IN
L
N
+ (brown)
– ( )white
1
2
1
2
Cables for monochrome versions:
or
1
2
+ (red)
– ( )black
1
2
Driver
LED
PX307
PX184
PY421-24V
7-12
PY415-12V
PY415-12V
PY421-24V
PY404-48V
4-6
1-3
4-6
1-3
Driver
LED
PX305
PX308
PX215
PY415-24V
PY415-24V
4-6
7-12
7-12
PY417-12V
PY417-12V
PY421-48V
PY417-12V
PY415-24V
PY421-48V
1-3
4-6
1-3
4-6
1-3
Power
supply
Quantity of
powered lamps
350 mA power supply 700 mA power supply
Quantity of
powered lamps
Power
supply
Driver
LED
PX307
PX184
PY421-24V
12
PY415-12V
PY415-12V
PY421-24V
PY404-48V
6
3
6
3
PY412 1-4
_
Driver
LED
PX308
PX215
PY415-24V
12
12
PY417-12V
PY421-48V
PY417-12V
PY415-24V
PY421-48V
6
3
6
3
PY410 1-4
_
PX305 PY415-24V 6
PY417-12V 3
350 mA power supply
700 mA power supply
Power
supply
Quantity of
powered lamps
Power
supply
Quantity of
powered lamps
driver LEDdriver LED

9
6. Dimensions
27
75 mm
48,5 mm
Number of LEDs:
Casing Material:
Casing IP class:
Max. power consumption:
Dimensions:
3
Stainless steel
IP 68
Diameter: 48.5 mm
Overall lamp height: 75 mm (version with handle)
~ 3,3 W (350 mA, full brightness, white color)
~ 8,1 W (700 mA, full brightness, white color)
7. Technical Data
48,5 mm
120 mm
48,3 mm
Version with handle (PX229-SH)
Version for flush mount (PX229-SP)
sealing O-ring stainless-steel tube
wall thickness: 2mm
5 mm

10
PXM Marek Żupnik sp. k.
ul. Przemysłowa 12
30-701 Kraków, Poland
PxAqua 3 SH/SP
PX 229
The PX229 can be operated only from the
power supply or current LED drivers with
a voltage adapted to the specifications of LEDs
and lamps connection setup.
Marek Żupnik M.Sc., Eng.
PN-EN 60598-1:2011
PN-EN 62031:2010
PN-EN 62471:2010
Name of producer:
Address of producer:
declares that the product:
Name of product:
Type:
answers the following product specifications:
Additional informations:
Kraków, 19.12.2011
DECLARATION OF CONFORMITY
according to guide lines of 2006/95/EC
stage and theatre consoles digital dimmers dmx systems architectural lighting controllers led lighting
tel: +48 12 626 46 92
fax: +48 12 626 46 94
e-mail: [email protected]
http://www.pxm.pl
ul. Przemysłowa 12
30-701 Kraków, Poland
Other manuals for PxAqua 3 SH
1
This manual suits for next models
1
Table of contents
Other PXM Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

Qazqa
Qazqa Suplux SL 3 Black 103062 instruction manual

Commercial Electric
Commercial Electric 54568141 Use and care guide

CREE LIGHTING
CREE LIGHTING 304 Series installation instructions

Goobay
Goobay 49867 user manual

ECOMAN ITALIA
ECOMAN ITALIA LED T8 instruction manual

Alkalite
Alkalite Krypton KT-81 user manual