PURONICS iGen User manual

Water Specialist iGen®
Control Valve
Programming and Cover Drawing Manual

Page 2iGen®Manual

iGen®Manual Page 3
Table of Contents
iGen® Front Cover and Drive Assembly................................................................................................................4
WS1 iGen® Drive Cap Assembly, Downflow Piston, Regenerant Piston and Spacer Stack Assembly ................5
WS1.25 iGen® Drive Cap Assembly, Downflow Piston, Regenerant Piston and Spacer Stack Assembly ...........6
Control Valve Function and Cycles of Operation....................................................................................................7
OEM General Instructions.......................................................................................................................................9
OEM Softener System Setup .................................................................................................................................10
OEM Filter System Setup......................................................................................................................................12
Installer Displays/Settings .....................................................................................................................................14
Service Alarm Settings ..........................................................................................................................................15
User Displays/Settings...........................................................................................................................................16
Diagnostics ............................................................................................................................................................19
Valve History .........................................................................................................................................................21

Page 4iGen®Manual
iGen®Front Cover and Drive Assembly
Drawing No. Order No. Description Quantity
1 V4165-01 WS1 iGen® FRONT COVER ASY 1
2 V3107-01 WS1 MOTOR 1
3 V3106-01 WS1 DRIVE BRACKET&SPRING CLIP 1
4 V4164PU-BOARD WS1 iGen® PCB REPLACE 1
5 V3110 WS1 DRIVE REDUCING GEAR 12X36 3
6 V3109 WS1 DRIVE GEAR COVER 1
7 V4166 WS1 iGen® BACK PLATE 1
8 V4169 WS1 iGen® WEATHER COVER 1
Not Shown V3186 WS1 AC ADAPTER 120V-12V 1
Battery Fully Seated
When replacing the battery, align
positives and push down to fully seat. Correct
Battery
Orientation
Battery replacement is
3 volt lithium coin cell
type 2032.
AC Adapter U.S.
Supply Voltage 120 V AC
Supply Frequency 60 Hz
Output Voltage 12 V AC
Output Current 500 mA
8
1
4
7
6
5
2
3

iGen®Manual Page 5
WS1 iGen®Drive Cap Assembly, Downflow Piston, Regenerant Piston and Spacer Stack Assembly
Drawing No. Order No. Description Quantity
1 V3005-02 WS1 SPACER STACK ASSEMBLY 1
2 V3004 DRIVE CAP ASY 1
3 V4166 WS1 iGen® BACK PLATE 1
4 V3011 WS1 PISTON DOWNFLOW ASY 1
5 V3174 WS1 REGENERANT PISTON 1
6 V3135 O-RING 228 1
7 V3180 O-RING 337 1
8 V3105 O-RING 215 (DISTRIBUTOR TUBE) 1
Not Shown V3001 WS1 BODY ASY DOWNFLOW 1
Note: The regenerant piston is not used in backwash only applications.
2
6
45
1
3
7
8
Black plug

Page 6iGen®Manual
WS1.25 iGen® Drive Cap Assembly, Downow Piston, Regenerant Piston and Spacer Stack Assembly
Drawing No. Order No. Description Quantity
1 V3430-01 WS1.5 SPACER STACK ASSEMBLY 1
2 V3004 DRIVE CAP ASY 1
3 V4166 WS1 iGen® BACK PLATE 1
4 V3407 WS125/15 PISTON DOWNFLOW ASY (AMBER) 1
5 V3174 WS1 REGENERANT PISTON 1
6 V3135 O-RING 228 1
7 V3180 O-RING 337 1
8 V3358 O-RING 219 (DISTRIBUTOR TUBE OPENING 1.32") 1
Not Shown V3020 WS1.25 BODY ASY DOWNFLOW (DISTRIBUTOR TUBE OPENING 1.32") 1
Note: The regenerant piston is not used in backwash only applications.
2
6
4
5
1
3
7
8
Grey plug

iGen®Manual Page 7
Control Valve Function and Cycles of Operation
Target Range Low Medium High
Lbs. of salt per 1 Ft2of resin <7.5 7.5 - 12.0 12>
Grains Capacity per lbs. of salt 6000 – 3501 3500 – 2501 2500 - 1700
Code Salting
Range
Backwash
Type
Fill
Type
Brine
Direction
Fill
Minutes
Service
Minutes
BW
Minutes
Rinse*
Minutes
Brine
Minutes
BW
Minutes
Rinse
Minutes
BW**
Minutes
Fill
Minutes
Fill**
Minutes
Softening
C1 Low Normal Post Down 6 45 3 3 0:22-78:13
C2 Medium Normal Post Down 8 60 8 4 0:22-78:13
C3 High Normal Post Down 8 75 10 6 0:22-78:13
C4 Low Longer Post Down 8 45 8 4 0:22-78:13
C5 Medium Longer Post Down 10 60 10 6 0:22-78:13
C6 High Longer Post Down 12 75 12 8 0:22-78:13
C7 Low Normal Pre Down 0:22-
78:13 120 6 45 3 3 0:05
C8 Medium Normal Pre Down 0:22-
78:13 120 8 60 8 4 0:05
C9 High Normal Pre Down 0:22-
78:13 120 8 75 10 6 0:05
C10 Low Longer Pre Down 0:22-
78:13 120 8 45 8 4 0:05
C11 Medium Longer Pre Down 0:22-
78:13 120 10 60 10 6 0:05
C12 High Longer Pre Down 0:22-
78:13 120 12 75 12 8 0:05
C21 Low Normal Post Up 0:15 45 6 3 0:22-78:13
C22 Medium Normal Post Up 0:15 60 10 4 0:22-78:13
C23 High Normal Post Up 0:15 75 12 6 0:22-78:13
C24 Low Longer Post Up 0:15 60 12 5 0:22-78:13
C25 Medium Longer Post Up 0:15 70 14 7 0:22-78:13
C26 High Longer Post Up 0:15 80 16 9 0:22-78:13
C27 Low Normal Pre Up 0:22-
78:13 120 0:15 45 6 3 0:05
C28 Medium Normal Pre Up 0:22-
78:13 120 0:15 60 10 4 0:05
C29 High Normal Pre Up 0:22-
78:13 120 0:15 75 12 6 0:05
C30 Low Longer Pre Up 0:22-
78:13 120 0:15 60 12 5 0:05
C31 Medium Longer Pre Up 0:22-
78:13 120 0:15 70 14 7 0:05
C32 High Longer Pre Up 0:22-
78:13 120 0:15 80 16 9 0:05
Filtering
C41 Fill OFF Normal NA Down 14 8 NA
C42 Fill OFF Longer NA Down 16 10 NA
C43 Fill OFF Normal 2 NA Down 8 6 10 8 NA
C44 Fill OFF Longer 2 NA Down 12 6 12 10 NA
C45 Fill ON Normal Post Down 14 60 8 0:30 0:00-39:50
C46 Fill ON Longer Post Down 16 60 10 0:30 0:00-39:50
C47 Fill ON Normal 2 Post Down 8 60 10 8 0:30 0:00-39:50
C48 Fill ON Longer 2 Post Down 12 60 12 10 0:30 0:00-39:50
C49 Fill ON Normal Pre Down 0:00-
39:50 120 14 60 8 0:30 0:05
C50 Fill ON Longer Pre Down 0:00-
39:50 120 16 60 10 0:30 0:05
C51 Fill ON Normal 2 Pre Down 0:00-
39:50 120 8 60 10 8 0:30 0:05
C52 Fill ON Longer 2 Pre Down 0:00-
39:50 120 12 60 12 10 0:30 0:05
Fill time varies, depending on settings. *Fixed for Upflow Softeners ** Fixed, non-adjustable cycle times

Page 8iGen®Manual
System Type Regeneration
Option
Regeneration
Type
Day
Override
Softening Auto Normal 1-28 days
Regeneration occurs at the next regeneration time when
volume capacity falls below the reserve capacity, or the
specied number of days is reached, whichever comes rst.
Softening Auto Normal OFF Regeneration occurs at the next regeneration time when
volume capacity falls below the reserve capacity.
Softening or
Filtering
20 – 50,000
Gallons Normal 1-28 days
Regeneration occurs at the next regeneration time when
volume capacity reaches 0, or the specied number of days
is reached, whichever comes rst.
Softening or
Filtering
20 – 50,000
Gallons Normal OFF Regeneration occurs at the next regeneration time when
volume capacity reaches 0.
Softening or
Filtering OFF Normal 1-28 days
Time Clock operation.
Regeneration occurs at the next regeneration time the
specied number of days is reached.
Softening
Auto or
20 – 50,000
Gallons
On 0 1-28 days
Regeneration occurs immediately when volume capacity
reaches 0, or the specied number of days is reached,
whichever comes rst.
Softening or
Filtering
20-50,000
Gallons On 0 OFF Regeneration occurs immediately when volume capacity
reaches 0.
Softening Auto Normal +
On 0 1-28 days
Regeneration occurs at the next regeneration time when
volume capacity falls below the reserve capacity, or the
specied number of days is reached, or regeneration occurs
after 10 minutes of no water usage when volume capacity
reaches 0.
Softening or
Filtering
20 – 50,000
Gallons
Normal +
On 0 1-28 days
Regeneration occurs at the next regeneration time the
specied number of days is reached or regeneration occurs
after 10 minutes of no water usage when volume capacity
reaches 0.
Softening Auto Normal +
On 0 OFF
Regeneration occurs at the next regeneration time when
volume capacity falls below the reserve capacity, or
regeneration occurs after 10 minutes of no water usage
when volume capacity reaches 0.
Setting Options Table
The control valve with a water meter can be set for
• Demand Initiated Regeneration (DIR) only
• Time Clock operation only
• DIR and Time Clock, whichever occurs rst, depending upon what settings are selected for Day Override and Gallon
Capacity
If a control valve does not contain a meter, the valve can only act as a time clock, and day override should be set to any
number and gallon capacity should be set to off.
The user can initiate manual regeneration. The user has the option to request the manual regeneration at the delayed
regeneration time or to have the regeneration occur immediately:
1. Press and release REGEN. “Regen Today” will ash on the display and the regeneration will occur at the delayed re
generation time. The user can cancel the request by pressing and releasing REGEN. NOTE: This method of manually
initiating regeneration is NOT allowed when the Regeneration Type is set to On 0.º
2. Press and hold REGEN for approximately 3 seconds to immediately start the regeneration. The user cannot cancel this
request, except by resetting the control by pressing NEXT and REGEN simultaneously for 3 seconds.
The control valve may be stepped through the regeneration cycles by pressing REGEN.

iGen®Manual Page 9
OEM General Instructions
The control valve offers multiple procedures that allow the valve to be modied to suit the needs of the installation. These
procedures are:
OEM Softener Setup
OEM Filter Setup
Installer Displays & Settings
Service Alarm Setup
User Displays & Settings
Diagnostics
Valve History
These procedures can be accessed in any order. Details on each of the procedures are provided on the following pages.
At the discretion of the manufacturer, the eld technician can access all settings. To “lock out” access to diagnostic and valve
history displays and modications to settings except hardness, day override, time of regeneration and time of day by anyone
but the manufacturer, press ▼, NEXT, ▲, and SET CLOCK in sequence after settings are made. To “unlock”, so other
displays can be viewed and changes can be made, press ▼, NEXT, ▲, and SET CLOCK in sequence.
When in operation normal user displays such as time of day, gallons remaining or days remaining before regeneration are
shown. When stepping through a procedure, if no buttons are pressed within ve minutes the display returns to a normal user
display. Any changes made prior to the ve minute time out are incorporated.
To quickly exit OEM Softener Setup, OEM Filter Setup, Installer Display Settings, Diagnostics or Valve History press SET
CLOCK. Any changes made prior to the exit are incorporated.
When desired all information in Diagnostics may be reset to zero when the valve is moved to a new location. To reset to zero,
press NEXT and ▼simultaneously to go to the Service/OEM 1 screen, and release. Press ▲and ▼simultaneously to reset
diagnostic values to zero. Screen will return to User Display.

Page 10 iGen®Manual
STEP 1S
OEM Softener System Setup
STEP 1S – Press NEXT and ▼simultaneously for 3 seconds. If screen in step 2S does
not appear in 5 seconds the lock on the valve is activated. To unlock press ▼, NEXT,
▲, and SET CLOCK in sequence, then press NEXT and ▼simultaneously for 3
seconds.
STEP 2S – Select Valve Type. Use ▲or ▼ to select between 1.0 and 1.25. Press NEXT
to go to Step 3S. Press REGEN to exit OEM Softener System Setup.
STEP 2S
STEP 3S – Choose Softening using ▲or ▼. Press NEXT to go to Step 4S. Press
REGEN to exit OEM Softener System Setup.
STEP 3S
STEP 4S – Enter the ion exchange capacity in grains of hardness as calcium carbonate
for the system based on test data using ▲or ▼. Press NEXT to go to Step 5S. Press
REGEN to return to previous step.
STEP 5S – Enter the pounds of salt per regeneration using ▲or ▼. Press NEXT to go
to Step 6S. Press REGEN to return to previous step.
STEP 4S
STEP 6S – Backwash: Select “NORMAL” or “LONGER” using ▲or ▼. Press NEXT
to go to Step 7S. Press REGEN to return to previous step.
STEP 6S
STEP 7S – Set Gallons Capacity using ▲or ▼:
• “AUTO” (reserve capacity automatically estimated and gallons capacity
automatically calculated from grains capacity and water hardness);
• “oFF” (regeneration based on day override); or
• number of gallons (20 to 50,000).
See Setting Options Table for more detail. Press NEXT to go to Step 8S. Press REGEN
to return to previous step.
STEP 7S
STEP 5S
Table of contents
Popular Control Unit manuals by other brands

Festo
Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation
JS Automation MPC3034A user manual

JAUDT
JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum
Spektrum Air Module System manual

BOC Edwards
BOC Edwards Q Series instruction manual

KHADAS
KHADAS BT Magic quick start

Etherma
Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations
PMFoundations Attenuverter Assembly guide

GEA
GEA VARIVENT Operating instruction

Walther Systemtechnik
Walther Systemtechnik VMS-05 Assembly instructions

Altronix
Altronix LINQ8PD Installation and programming manual