PTS-G5K13M PTS Co., Ltd. 8
2-3 Control Specification
The RF Generator is Analog mode and Manual Mode by which RS-232C
output control is possible (on request, Device-net control would be available
as optional specification).
①Analog Mode
Via D-sub 25 pin terminal on the back of Generator, power can be
controlled through interlock confirmed by Analog Voltage.
②Manual Mode
Connect the Handy Controller provided on the front of the Power Control.
Setting Parameters can be various to make the Interlock OK.
③RS-232C Mode(Device-net option available up on selection): Power
Control can be controlled via RS-232C terminal (Device-Net Selectable) on
the rear of Generator.
2-4 Installation site
①Please maintain the ambient temperature to 5 ~ 40 ℃ when the generator
is in operation( Power output ON)
②Please keep in storage area of temperature -25 ~ 55 ℃ when it is not under
operation.
③Do not install in places with high humidity, dusty, where there is a direct
sunlight or places where there is any risk of water or other liquid leakage.
Getting the product wet with water or other liquid may cause damage that
cannot be repaired.
④Use and store in a level and stable place.
2-5 Installation Requirements
①Fill out the front and rear of the cooling fan blower of the product smoothly.
②Make a space and exhaust fan from front(>15cm), side(>15cm), rear (>30cm)
③Set up exhaust fan in the rack more than6㎥/min.
3. Dimensions