Protege PRT-CTRL-SE User manual

Protégé® SE Integrated System Controller
Installaon Manual
PRT-CTRL-SE
PENDING

The specicaons and descripons of products and services contained in this manual were correct at the me of prinng. Integrated Control Technology Limited
reserves the right to change specicaons or withdraw products without noce. No part of this document may be reproduced, photocopied, or transmied in any
form or by any means (electronic or mechanical), for any purpose, without the express wrien permission of Integrated Control Technology Limited. Designed and
manufactured by Integrated Control Technology Limited. Protégé® and the Protégé® Logo are registered trademarks of Integrated Control Technology Limited. All
other brand or product names are trademarks or registered trademarks of their respecve holders.
Copyright © Integrated Control Technology Limited 2003-2010. All rights reserved.

Table of Contents
1.0 Welcome ............................................................................................................................2
2.0 Protégé®System Management Suite ..................................................................................3
2.1 Protégé® Modules............................................................................................................... 3
3.0 Mounng ...........................................................................................................................4
4.0 Connecons........................................................................................................................5
4.1 Cabinet Enclosure Tamper Switch ....................................................................................... 5
4.2 Earth Ground Connecon.................................................................................................... 5
4.3 AC Power ............................................................................................................................. 6
4.4 Baery Backup .................................................................................................................... 7
4.5 Baery Charge Current Seng ........................................................................................... 8
4.6 Status Indicator ................................................................................................................... 9
4.7 Encrypted Module Network ................................................................................................ 9
4.8 Telephone Dialer................................................................................................................ 11
4.9 Expansion Connector......................................................................................................... 12
4.10 Ethernet 10/100 Network Interface ................................................................................ 13
5.0 Door Access Control..........................................................................................................14
5.1 Card Reader Connecon.................................................................................................... 14
5.2 Mulple Wiegand Card Reader Connecon ...................................................................... 15
5.3 Door Contact Connecon .................................................................................................. 16
5.4 Lock Output Connecon .................................................................................................... 17
5.5 Programming the Onboard Reader................................................................................... 18
6.0 Inputs...............................................................................................................................19
6.1 Zones................................................................................................................................. 19
6.2 Resistor Value Opons....................................................................................................... 20
6.3 Trouble Zones .................................................................................................................... 21
7.0 Programmable Outputs ....................................................................................................22
7.1 Bell/Siren PGM Outputs .................................................................................................... 22
7.2 PGM 3/4 Outputs .............................................................................................................. 23
7.3 Reader PGMs..................................................................................................................... 23
8.0 Hardware Conguraon ...................................................................................................24
8.1 Conguraon Switch......................................................................................................... 24
8.2 Defaulng a Controller...................................................................................................... 25

9.0 LED Indicators...................................................................................................................26
9.1 Status LED ......................................................................................................................... 26
9.2 Fault Indicator ................................................................................................................... 26
9.3 Charge/Test Indicator........................................................................................................ 26
9.4 Auxiliary OK Indicator........................................................................................................ 26
9.5 AC OK Indicator ................................................................................................................. 26
9.6 5V Isolated Power Indicator .............................................................................................. 26
9.7 Bell 1/Bell 2 Indicators ...................................................................................................... 27
9.8 Network RX/TX Indicators ................................................................................................. 27
9.9 Ethernet Link Indicator ...................................................................................................... 27
9.10 100Mb Indicator.............................................................................................................. 27
9.11 R1/R2 Data Indicators ..................................................................................................... 27
9.12 Online Indicator............................................................................................................... 27
10.0 Mechanical Diagram .........................................................................................................28
11.0 Mechanical Layout............................................................................................................29
12.0 System Capacies .............................................................................................................30
13.0 Technical Specicaons ....................................................................................................31
13.1 Current and Validaon Example 1................................................................................... 32
13.2 Current and Validaon Example 2................................................................................... 33
13.3 Current and Validaon Example 3................................................................................... 34
14.0 Ordering Informaon........................................................................................................35
15.0 Warranty ..........................................................................................................................36

1.0 Welcome!
Thank you for purchasing the Protégé® SE Integrated System Controller by Integrated Control
Technology. The Protégé® System is an advanced technology security system specically designed
to enhance the funconality of condominium and apartment security with exible local monitoring
and osite communicaon.
The Protégé® SE Integrated System Controller is the central processing unit of the Protégé® System.
The Protégé® SE Integrated System Controller communicates with all system modules, stores all
conguraon and transacon informaon, process’s all system communicaon and reports alarms
and system acvity to a monitoring staon or remote computer.
Flexible module network architecture allows large numbers of modules to be connected to the
RS-485 Module Network. Up to 250 modules can be connected to the Protégé® SE Integrated
System Controller in any combinaon to the network up to a distance of 900m (3000).
The current features of the Protégé® SE Integrated System Controller include:
• Internal industry standard 10/100 Ethernet
• 32 Bit advanced RISC processor with 2MB RAM and 4MB ash
• 16x high security monitored zone inputs
• NIST Cered AES 256 Bit Encrypon
When receiving the Protégé® SE Integrated System Controller you should nd the kit contains the
items listed below. The kit type is clearly labelled on the packaging and will tell you what your kit
contains. Please note that if you do not have the correct contents contact your distributor
immediately.
• Protégé® SE Integrated System Controller
• Protégé® SE Integrated System Controller Quick Start Guide
• 6x nylon spacers
• 36x 1K ohm resistors
• Red/black baery backup wires
• 2x Diode 1N4007 1A 400V (Axial)
For more informaon on the Protégé® SE Integrated System Controller and other Integrated Control
Technology products please login to www.incontrol.co.nz.
!Indicates a warning or advisory message relang to the secon or locaon.
?Indicates a hint or suggeson that relates to the secon or locaon.
[TEXT] Bold text enclosed in brackets is used to show a secon number or address of
a programmable opon or informaon on programming shortcut sequences.
Italics Italic text shows a reference to a secon, page, manual or website.
2

2.0 Protégé® System Management Suite
The Protégé® System Management Suite applicaon is a Windows®™ based Integrated Access
Control and Alarm Management System designed for any conguraon from single site, single
Protégé® SE Integrated System Controller applicaons up to global mul-naonal corporaons
using mulple site, mulple Protégé® SE Integrated System Controller installaons.
Product Code Descripon
PRT-SMGT-ENT Protégé® System Management Suite Enterprise Edion
PRT-SMGT-PRO Protégé® System Management Suite Professional Edion
PRT-SMGT-STN Protégé® System Management Suite Standard Edion
PRT-SMGT-1U Protégé® System Management Single Client License Edion
2.1 Protégé® Modules
The Protégé® System can be expanded to accommodate large numbers of modules using the
encrypted RS-485 Network. Modules that are currently available are listed below. Visit
www.incontrol.co.nz for the latest Protégé® Module and product informaon.
Product Code Descripon
PRT-CTRL-SE Protégé® SE Integrated System Controller
PRT-CTRL-LE Protégé® LE Integrated System Controller
PRT-TLCD Protégé® Touchscreen Keypad
PRT-ATH1 Protégé® Temperature and Humidity Sensor
PRT-KLCD Protégé® Alphanumeric LCD Keypad
PRT-ZX16-PCB Protégé® 16 Zone Input Expander
PRT-ZXS16-PCB Protégé® Standard 16 Zone Input Expander
PRT-PX16-PCB Protégé® 16 PGM Output Expander
PRT-PXS16-PCB Protégé® Standard 16 PGM Output Expander
PRT-RDM2-PCB Protégé® Mini 2 Reader Expander
PRT-RDS2-PCB Protégé® Standard 2 Reader Expander
PRT-RDI2-PCB Protégé® Intelligent 2 Reader Expander
PRT-RDE2-PCB Protégé® Ethernet 2 Reader Expander
PRT-ADC4-PCB Protégé® Analog Input Expander
PRT-DAC4-PCB Protégé® Analog Output Expander
PRT-COMM Protégé® RS-232 Serial Communicaon Interface
PRT-PX16-DRI Protégé® 16 Input Desnaon Reporng Interface
PRT-PSU-5I Protégé® Intelligent 5 Amp Power Supply
PRT-HIO Protégé® Hi-O Network Door Control Module
3

3.0 Mounng
The Protégé® SE Integrated System Controller is supplied as a PCB only (Printed Circuit Board). It
is recommended that the gear plate style enclosures be used where possible, as this provides the
best mounng and installaon soluon as well as the required cable entry and
terminaon space.
When installing the Protégé® SE Integrated System Controller ensure that there is adequate
clearance around all sides of the cabinet enclosure and air ow to the vents of the enclosure are
not restricted.
It is recommended to install the Protégé® SE Integrated System Controller in a locaon that will
facilitate easy access for wiring. It is also recommended that the Protégé® SE Integrated System
Controller is installed in electrical rooms, communicaon equipment rooms, closets or in an
accessible area of the ceiling.
Step 1
Insert the plasc standos in to the locaons to mount the PCB board.
Step 2
Calculate the locaon and posion of the cabinet enclosure and mark the holes for the keyhole
points in the top le and right locaons. This will allow you to screw in the screws and then hang
the box on them adjusng the locaon to suit.
Step 3
Ensure a solid xing point and screw in the two screws. Before ghtening the top screws insert the
tamper bracket in the slot provided on the right side of the cabinet enclosure.
Step 4
Fix the cabinet enclosure securely using the remaining mounng holes on the boom le, right
and centre of the cabinet enclosure.
Step 5
If you are extending the Protégé® SE Integrated System Controller by the addion of a
communicaons module or memory interface insert the 4 extended nylon standos through the
rear of the Protégé® SE Integrated System Controller.
Step 6
Insert the PCB in to the cabinet enclosure and mount using the plasc standos inserted during
step 1.
!
It is recommended to install the cabinet enclosure when the circuit board is not
installed on the plasc standos as this will reduce the risk of damage caused by
debris during the installaon.
4

5
4.0 Connecons
4.1 Cabinet Enclosure Tamper Switch
The cabinet enclosure tamper input signals to the monitoring staon or remote computer that an
cabinet enclosure has been opened. The tamper input switch should be mounted into the steel
bracket provided and connected to the tamper connecon terminals as shown in gure 1 below.
4.2 Earth Ground Connecon
The Protégé® SE Integrated System Controller has a connecon for earth ground. For best results a
cold water pipe should be used with a pipe wiring clamp. If a cold water pipe is not available
connect to a suitable ground connecon in the installaon. A minimum 14AWG solid copper wire
should be used from the Protégé® SE Integrated System Controller’s earth connecon point to the
clamp on the cold water pipe. If other earth clamps are present at the same connecon point
connect the clamp below the exisng units.
Figure 1 - Tamper Input Connecon
Figure 2 - Earth Ground Connecon
!
The telephone communicaon dialer contains a separate earth connecon. Do not
loop the earth connecon from the dialer to the earth of the Protégé® SE
Integrated System Controller. A separate connecon should be connected to the
same earth point.
AC AC B+ B- ST TP TP
Bracket
Ta mper Switch
AC AC B+ B- ST TP TP

6
4.3 AC Power
The Protégé® SE Integrated System Controller should be supplied by a dedicated electrical power
source rated for a minimum 10Amp load and have a dedicated circuit breaker. Do not use a switch
controlled breaker or a switched electrical point to supply electrical power. Connect the primary of
a 16VAC, 50/60Hz, 40VA transformer to the electrical circuit and run the secondary to the AC Input
on the Protégé® SE Integrated System Controller terminals.
Specic regional regulaons may allow the transformer to be mounted inside the cabinet
enclosure. In this case wire the electrical circuit to the electrical terminaon point inside the
cabinet enclosure and the secondary wires of the transformer to the AC Input on the Protégé® SE
Integrated System Controller. The earth wire should be routed to the terminal on the Protégé® SE
Integrated System Controller when using an internal transformer.
!
Terminaon of wiring to the Protégé® SE Integrated System Controller while power
is applied or the baery is connected may cause serious damage to the Protégé®
SE Integrated System Controller and will VOID ALL WARRANTIES OR GUARANTEES.
Power the unit only aer all wiring, conguraon and jumper sengs are
completed.
Figure 3 - AC Power Connecon
AC AC B+ B- ST TP TP
Transformer
Mains Input

7
4.4 Baery Backup
It is recommended that a minimum of a 4Ah baery is used as the main baery backup. From the
accessory bag provided, connect the red and black baery terminaon wires to the B+ and B-
terminals. Connect the spade terminals to the baery as shown in gure 4 below. Connecon of
the baery in reverse will not damage the Protégé® SE Integrated System Controller but will cause
the electronic baery fuse (5A fast blow) to open. Prolonged reverse connecon can cause damage
to the Protégé® SE Integrated System Controller.
The baery test procedure uses a special algorithm to prevent deep discharge and increase baery
endurance. A dynamic baery test is performed every ten minutes (default) when AC power is
present. A baery trouble zone alarm will be generated if the baery is either disconnected or
shows poor capacity. Baery fault condions will acvate the baery trouble zone.
If AC is not present the Protégé® SE Integrated System Controller will monitor the baery for a low
voltage level and will acvate the baery trouble zone. The next dynamic baery test will
occur 30 minutes aer AC power has been restored. This delay allows the baery to achieve
opmal charging during the rst 30 minutes that power has been restored to the unit. Once the
rst test is completed the dynamic tesng will return to the programmed value (default 10
minutes).
When power is rst applied to the Protégé® SE Integrated System Controller a dynamic baery test
will be performed aer 30 seconds, this allows the status and condion of the baery to be
detected. On compleon of this rst test the default tesng period of 10 minutes will be resumed,
this is a programmable seng in the Protégé® SE Integrated System Controller panel opons. The
test period can be changed as required by seng the baery test me in the Protégé® SE
Integrated System Controller Conguraon Menu.
!
Only aach standard lead acid baeries. Do not connect the baery wires or B+
and B- terminals of the Protégé® SE Integrated System Controller to any other
ancillary device (siren, lock or mag clamp etc). Connecon may cause erroneous
faults or serious damage to the Protégé® SE Integrated System Controller and will
VOID ALL WARRANTIES OR GUARANTEES.
Figure 4 - Baery Connecon
AC AC B+ B- ST TP TP
Gel Cell Backup Ba�ery
+
-
Table of contents