PROEL AMP30XL User manual

MANUALE UTENTE – USER’S MANUAL
Amplificatore PA Integrato
PA Mixing Amplifier
AMP30XL / AMP60XL / AMP120XL

1. IMPORTANT SAFETY INSTRUCTIONS
CAUTION: To reduce the risk of electric shock do not remove cover (or back panel). No
user serviceable parts inside. Refer servicing to qualified personnel only.
WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to
rain or moisture.
This symbol is intended to alert the user of the presence of uninsulated
dangerous voltage within the product enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the user of the presence of important operating
and maintenance (servicing) instruction in the literature accompanying the
appliance. Please carefully read the owner’s manual.
INSTRUCTIONS:
All safety and operating instructions should be read before the product is operated.
Retain these instructions:
All safety and operating instructions should be retained for future reference.
This owner’s manual should be considered as a part of the product and it must accompany it
every time, and delivered to the new user when this product is sold. In this way the new owner will
be aware of all the installations, operating and safety instructions.
Heed all warnings:
All warnings on the product and in owner’s manual should be adhered to.
Heed all warnings.
Follow all instructions:
All operating and user’s instructions must be followed.

Sentences preceded by symbol contain important safety instruction. Please read it carefully.
DETAILED SAFETY INSTRUCTIONS.
Water and moisture:
This apparatus should not be used near water (i.e. bathtub, kitchen sink, swimming pools,
etc.)
Ventilation:
This apparatus should be placed in a way that his position doesn’t interfere with correct
ventilation. This unit, for example, should not be placed on a bed, sofa cover o similar
surfaces that could cover ventilation openings, or placed in a built-in installation, such a
bookcase or a cabinet that could block air flow trough ventilation openings.
Heat:
This apparatus should be placed away from heat sources, like radiators, heat registers, stoves
or other products (including amplifiers) that produce heat.
Power sources:
• This apparatus should be connected only to power source type specified in this owner’s
manual or on the unit.
• If the supplied AC power cable plug is different from wall socket, please contact an
electrician to change the AC power plug.
Grounding or Polarization:
• All precautions must be observed in order to avoid grounding or polarization defeating.
• Unit metal parts are grounded through the AC power cord.
• If the AC power outlet doesn’t have grounding, consult an electrician for outlet grounding.
Power cord protection:
The power cord should be routed in a way it will not be walked on or pinched by items placed
upon or against it, paying particular attention to cords at plugs, convenience receptacles and
wall outlet.
Cleaning:
• You can clean the unit with a compressed air flow or a wet cloth.
• Don’t clean the unit using solvents like trichloroethylene, thinners, alcohol, or other fluids
with very strong volatility and flammability.
Non use periods:
The unit AC power cord should be unplugged from the outlet if it’s unused for a long period.

Objects or liquid entry inside the unit:
Be careful that no objects fall or liquid is spilled inside the unit through ventilation openings.
Safe power line use:
• Keep firmly the plug and the wall outlet while disconnecting the unit from AC power.
• When the unit will not be used for a long period of time, please unplug the power cord
from AC power outlet.
• To avoid unit power cord damaging, please don’t strain the AC power cable and don’t
bundle it.
• In order to avoid unit power cord damaging, please be sure that the power cord is not
walked on or pinched by heavy objects.
Unit relocation:
Before any unit relocation please control the unit is turned off. The power cord must be
unplugged by the wall outlet, and all the connections wires should be disconnected as well.
Don’t open this unit:
Don’t attempt to open or to repair by yourself this unit. For any problem solution not described
in this owner’s manual, please refer to qualified personnel only or consult us or your National
Distributor. Any improper operation could result in fire or electric shock.
Damages requiring services:
• Don’t attempt to do operations not described in this user’s manual.
• In the following cases please refer to an authorized maintenance center or skilled
personnel:
- When the unit works improperly or it doesn’t work at all.
- If power cord or plug are damaged.
- If liquid has spilled, or objects have fallen into the unit.
- The unit has been exposed to rain.
- The unit doesn’t operate normally o it exhibits a marked change in performance.
- If the product has dropped or it has been damaged in any way.
Maintenance:
The user shouldn’t attempt maintenance operation not described in this user’s manual. Every
maintenance operation should be done by qualified personnel only.
IMPORTANT SAFETY INSTRUCTIONS:
• Install this unit following owner’s manual instructions.
• Don’t install, connect or disconnect power supply when the unit is powered, otherwise
there’s an high risk of electric shock.
• Don’t open the unit, there are no user serviceable parts inside.
• If you detect a particular smell from the unit, please immediately turn it off and disconnect
the AC power cord.
• Don’t block the unit ventilation openings.
• Avoid using this unit in overload for a long period.
• Don’t force commands (switches, controls, etc.)

• To obtain good speakers wire contacts, please tighten the screw terminals firmly.
• For safety reason, don’t defeat the grounding connection. Grounding is useful for user
safety.
• Use only connectors and accessories suggested by the manufacturer. .
• This unit should be placed in a rack (see INSTALLATION) and kept far from:
Wet places
Direct exposure to heat sources (like sun light)
Non properly ventilated places
• Disconnect the power cord during storms or when the unit is not used.
• In order to prevent fire and electric shock risks, it’s necessary to keep the unit far
from sprinkling and drops. Please don’t put cups, vases or other object containing liquids
over the unit. In case of interferences from source signal, THD value will raise over 10%.
Don’t place this unit in a bookshelf o in other places with small room.
• PROEL S.P.A. is not responsible for any damage that occurs due to a wrong unit
installation.
Thank you for choosing one of Proel products, and for your confidence towards
our brand, synonymous of professionalism, accuracy, high quality and reliability.
All our products are CE approved and designed for continuous use in
professional installation systems.
2. DESCRIPTION
AUP series amplifier has been specifically designed for paging, music, and
sound reinforcement applications in P.A. systems.
FEATURES:
• Protection circuit for speaker short circuit and overload.
• INPUT1 priority over the other inputs (vocal activation).
• Manual priority of INPUT1, INPUT2, and INPUT3 over the inputs.
• LED power on indicator.
• LED level indicator.
• Volume master control.
• Discrete volume control for inputs 1 – 5.
• Bass and treble EQ controls.
• Ground connection screw.
• Four universal XLR inputs, with mic/line sensitivity selection and
switchable 24 V DC phantom power.
• MAIN IN input.

• AUX RCA stereo CD/TAPE/TUNER input with selectable
sensitivity.
• Four discrete outputs. Constant impedance output (4Ω) and three
constant voltage outputs (25V - 70 V – 100 V).
• PRE OUT output.
• TAPE OUTPUT.
• Switchable power supply (115V – 230 V).
• Emergency 24 V DC power supply.
3. FRONT PANEL DESCRIPTION
fig.1
8) POWER switch.
9) MASTER volume control.
10) TREBLE EQ control.
11) BASS EQ control.
12) LED power indicator.
13) INPUT1 - INPUT5 volume controls.
14) OUTPUT LED Vu-meter.

4. REAR PANEL DESCRIPTION
fig.2
1) AC power selector.
2) TAPE OUTPUT connectors.
3) AUX INPUT (INPUT5) connectors.
4) INPUT1 ÷ INPUT4 connectors.
5) Fuse folder.
6) IEC AC power socket.
7) DC power terminals.
8) Speaker output terminals.
9) AUX INPUT sensitivity selector.
10)COM terminal for outputs 11), and 12).
11)Output terminal for auxiliary speaker.
12)0dB output terminal.
13)Voice priority terminal.
14)COM terminal for outputs 13), 15), and 16).
15)PRE OUT terminal.
16)MAIN IN terminal.
17)INPUT1 - INPUT4 sensitivity selector.
18)Grounding terminal.

5. INSTALLATION
1. Inputs wiring
• INPUT1, INPUT2, INPUT3, and INPUT4 have a balanced XLR
connector, useful to connect both low impedance microphones (30-
600Ω), both condenser microphones with 24V phantom power supply,
both line level audio sources (i.e. AM/FM tuner, cassette deck, CD
player, etc.). To choose the source to be connected, please use
the following selectors position (fig. 2 ref. 17): LINE position for
AM/FM tuner, CD player, Cassette deck etc., MIC position for low-
impedance dynamic microphones and PHANTOM position for
condenser microphones. INPUT1 is provided of VOX feature, when
a signal is detected, this input signal has priority over all the other
inputs, excluding all the other input signals. In this way only INPUT1
audio signal is amplified.
Attention
-Never connect a dynamic microphone when PHANTOM power is turned on, the
dynamic microphone could be damaged.
-Turn off PHANTOM power before connecting/disconnecting microphones connectors.
-Be sure that PHANTOM power is not turned on when you use microphones not
requiring external power. The phantom power, applied at pin 2 and pin 3, could
damage these microphones.

• AUX INPUT (INPUT 5).
L e R RCA input connectors allow the input of a stereo signal by left
(L) and right (R) inputs. This stereo input is useful to connect a
stereo external audio source.
• MAIN IN input and PRE OUT output.
MAIN IN input is connected to PRE OUT output by a jumper. It’s
possible to improve the overall sound quality inserting an external
unit (i.e. equalizer, compressor etc.). For connection wiring please
refer to the following picture.

• 24V DC input terminals
These two terminals allow the unit to be DC powered by an external
power source (i.e. 24V generator or battery). In case of AC power
fault or black out, the unit will be powered by 24 V DC, with automatic
and silent switchover to backup power.
• AC power IEC socket.
This IEC socket is intended to connect AC linecord to the AC outlet
(fig. 2 ref. 6).
Attention
Before connecting the AC linecord to the unit, please control that AC
power selector (fig. 2 ref. 1) matches the outlet AC power.
2. Output connections
Attention
To prevent the risk of electric shock, never touch amplifier outputs
when the amplifier is turned on.
• Speakers connection.
To access to the speaker connection terminals (fig. 2 ref. 8) remove
the protection cover unscrewing the screws.
This unit can be used both with constant impedance speakers (4Ω)
and with constant voltage speakers (25V, 70V, and 100V). Make
connections applying following instructions.
This manual suits for next models
2
Table of contents
Other PROEL Amplifier manuals

PROEL
PROEL HP A450 User manual

PROEL
PROEL AUP160D User manual

PROEL
PROEL PRL250 User manual

PROEL
PROEL ATMP160XL User manual

PROEL
PROEL HPD2004 User manual

PROEL
PROEL HP-X series User manual

PROEL
PROEL AMP 240Z4 User manual

PROEL
PROEL AMP03 User manual

PROEL
PROEL Axiom HPD3400PFC User manual

PROEL
PROEL HPAMP104 User manual

PROEL
PROEL PSA 240 User manual

PROEL
PROEL DPX1000 User manual

PROEL
PROEL AMP03VR User manual

PROEL
PROEL AXIOM DSO26 User manual

PROEL
PROEL PMA 120 User manual

PROEL
PROEL HP-X series User manual

PROEL
PROEL HP-X 6000 User manual

PROEL
PROEL AMP160XL User manual

PROEL
PROEL APW1000 User manual

PROEL
PROEL AUP4125S User manual