1.5. Internal heat station
Resonant capacitors Mounting space provided for sixteen
capacitors. Eight 210nF, 500V or 8
200nF, 700V capacitors supplied.
330nf available
Series Parallel Capacitor Rail Kit available (optional)
Series inductor Adjustable for load matching
1.6. Protection
Power Limited to 12.5kW in any feedback
configuration
Inverter output current Limited to 250A peak. Short circuit
protected.
Resonant capacitor voltage Limited to 500V rms
Line current 50A Circuit breaker
DC link current 80A Semiconductor fuse
Temperature and cooling water Temperature switch on inlet water.
Differential pressure switch between
water inlet and outlet.
Safety Interlocks Emergency stop button or door switch
opens the main circuit breaker.
1.7. Load
Quality factor of load Will operate with any load Q (including
resistive loads), provided that the
output frequency and voltage is within
the specifications.
Connection Selectable between left and right.
Custom output connection provided.
1.8. Cooling water
Maximum pressure 100PSI (690kPa)
Minimum differential pressure 30PSI (207kPa)
Minimum water flow 2GPM (0.126l/s)
Maximum inlet water temperature 110F (43.3C)
Minimum inlet water temperature Approx. 90º F (32ºC)**
Minimum water resistivity 590.in (1500.cm)
Supply hose location Selectable between left or right
** must be set above dew point (see page 29)
5