PNI DU160 User manual

PNI DU160
Sistem automatizare deschidere usa
Automatic door opening system
User manual . . . . . . . . . . . . . . . . . 2
Manual de utilizare . . . . . . . . . . . .20

Operational Instructions
For Side-mounted Flat Automatic Door
Operator
Model:PNI DU160
Contents
Chapter 1: Product introduction.
1.1 Work flow
1.2 Product Characteristics
1.3 Main Technical Parameters
Chapter II : Installation
2.1 Installation of mechanical part of door opener
2.2 Connection of electrical part of door opener
Chapter 3: Parameter Setting and State Display
3.1 Parameter Setting
3.2 State Display Description
3.3 Error Alarm

-1-
Chapter IV: Debugging
4.1 Closing Position Learning
4.2 Opening Debugging
4.3 Closing Debugging
4.4 Other Debugging
Chapter V: Common troubles and Removal
...........................................................................................................................................
Parking List
Chapter 1 Product Introduction
In order to meet the automation requirements of modern flat-opening
door, our company has developed and produced intelligent automatic
door opening/closing machine, which adopts microcomputer chip, digital
control, powerful function, high safety performance, easy installation and
debugging.
Note: In order to use the equipment better and more comprehensively,
please read the operation instructions carefully before you install and
use it.
1.1 Work flow:
A. Main Process:
open the door→open & slow down→keep in place→close the
door→close & slow down→lock the door.
B. Detailed Work flow :
Step 1: The open signal from external equipment triggers the
electromagnetic lock of the door-opener to shut down.

-2-
Step 2: Open the door (permissible speed 1 to 10 gears, see
Chapter3 ).
Step 3 : Open & slow down(permissible speed 1 to 9 gears, see
Chapter 3 ).
Step 4: Stop it.
Step 5: Open &hold (permissible time 1 to 99 seconds, see
Chapter3).
Step6: Close the door (permissible speed 1 to 9 gears, see Chapter
3 ).
Step7: Close & slow down(permissible speed 1 to 9 gears, see
Chapter 3)
Step8: Electromagnetic lock power on.
Step9: Press door closed.
End of a work flow.
Note: In the process of closing the door, if there is a trigger signal for
opening the door, the action of opening the door will be executed
immediately.
1.2 Product Characteristics
1). Low consumption, static power :0.5W, maximum power: 25W.
2). Super silence, working noise less than 50 dB.
3). Small size, easy installation.
4). Powerful, maximum push door weight 140 Kg.
5). Support multiple signal input, relay signal, voltage signal (5-24V).
6). motor over-current, overload, short-circuit protection.

-3-
7). Intelligent resistance, push-door reverse protection.
8). Motor current (thrust), speed accurate regulation.
9). Self-learning limitation, abandoning tedious limitation debugging.
10). Enclosed shell,rain and dust proof.
1.3 Main Technical Parameters
Product Types
DU160
Range of
application
Various flat-open doors with
the width ≤ 1600mm and the weight ≤ 140Kg
Open Angle
90°
Power Supply
230V AC - 24V DC 5A
Rated Power
25W
Static Power
0.5W(no electromagnetic lock)
Open/Close Speed
1-9 gears,
adjustable (corresponding opening time 10-3S)
Open Hold Time
1~99 seconds
Protection
degree IP54
Operating
Temp/Humidity
-26℃~60℃
30%~95%(no condensation)
Atmospheric
Pressure
700hPa~1060hPa
External Size
L 360mm * W 83mm* H 131mm
Net Weight
about 7.3kg

-4-
Chapter II Installation
Installation Notes:
A. Considering the influence of wind resistance, force arm and other
factors, the maximum width of the door for the door opener is 1.6
meters. The weight of the door should be less than 90 kg, the
width of the door should be reduced by 0.1 meters, and the
weight can be increased by 10 Kg. By analogy, the width of the
door with 1.1 meters can reach 140 Kg, slightly overweight will
not affect the life of the door opener.But it will affect the
opening/closing speed.
B. Installation must be carried out according to the size provided in
the instructions. Improper Installation will directly cause the
door opener to fail to work properly and damage the equipment
in serious cases.
C. During installation, it is forbidden to change the structure of the
door opener. and no holes can be made in the shell to avoid water and
air entering and causing electronic and electrical componentsfailure.
2.1 Installation of mechanical part of door opener .
2.1.1
Installation instructions:
A. Distinction of left/right door opening: Clockwise door opening
direction is left door, conversely, counter-clockwise door opening direction
is right door .
B. The door opener should be mounted vertically with the door post. Pay

-5-
attention to the rotation direction of the connecting rod. Installation is as
follows:
Left Open Door:
7
Right Open Door:
C. Install the main body of the door opener according to the size
provided in 2.1.2 and 2.1.3.
D. Remove the crank fixed screw and gasket from the main shaft of

-6-
the door opener.
E. Put the perforated end of the crank assembly into the main shaft
of the door opener. Remember to make the position of the key way on the
hole aligned with the key of the main shaft, next lock the crank with
gasket and screw.
F. Fix the L-type mounting seat on the crank to the door ,with the
fixed screw M8*70 and the flat cushion nut M8.
Note: When installing, the L-type mounting seat, crank and main shaft
of the door opener should be on the same horizontal plane. Otherwise,
the crank up and down plane will be forced andblocked.
2.1.2
Left open door installation method and size.
As follows:
2.1.3
Right open door installation method and size.
As follows:

-7-
2.2 Connection of electrical part of door opener
2.2.1
Description of the control port:

-8-
Warning: A. When the electrical part is connected, live work is strictly
prohibited.Power can be energized after all connections .
B. Do not connect the positive and negative poles of the power supply
inverse, otherwise the equipment will be damaged.
Note: A. Please choose an electromagnetic lock with supply voltageis 12V DC and
the power ≤9W or our company's electromagnetic lock.Otherwise it will cause
abnormal operation or circuit damage.
B: When leaving factory, the motor wire has been connected, do not take it
out without any special case.
C: Opening signal of external access control equipment :
a: When the access control equipment is the output of switch quantity (dry
contact), the close switch controls the opening of the door, and the switch should be
open usually, without polarity requirements.
b: When voltage output (wet contact), add transfer module.
Name
Open Door
Control Signal
Fire fighting
linkage
Electromagnetic
lock
Power Supply
door
opener
+12
V
NO
GND
FIR
GND
+12V
negative
GND
+24V
Switch
Power
COM or
-V
+V
Electroma
gnetic
Lock
red
line
black
line
Access
Control
Machine
+12
V
NO
COM
GND
Table of contents
Languages:
Popular Door Opening System manuals by other brands

Normstahl
Normstahl IDO7 installation manual

Häfele
Häfele Finetta T 70 VF manual

AGS
AGS D-PL Instructions for fitting, operating and maintenance

Stanley
Stanley MA900ñ Installation and owner's manual

WITTUR
WITTUR Hydra Plus UD300 Instruction handbook

Alutech
Alutech TR-3019-230E-ICU Assembly and operation manual