Piranha HemiTor User manual

HemiTor
Precision
Pump System
Piranha Color Systems
3531 Thomas Rd.
Santa Clara, Ca 95054
www.HemiTorPump.com
HemiTor Operating Manual

HemiTor Operating Manual
1
Piranha Color Systems
HemiTor™ Pump System
Single Use, Pulse Free
A Positive Displacement, Single Use, Full Vacuum pump head for use in any circulated fluid application
where pulsation needs to be minimized and prevention of cross-contamination of pumped fluids is
critical.
Is your fluid path sensitive to pulsation or cross-contamination? Many UF/DF
(ultrafiltration/diafiltration), culture media, and bioreactor perfusion applications are sensitive to the
pulsation from peristaltic pumps. Even at low RPM, peristaltic pump operation can lead to undesirable
foaming, bubbles, and cell shear.
The HemiTor™ pump system is a groundbreaking new product for the manufacturing and bioprocess lab
that enables a completely integrated, disposable flow-path, liquid handling system that is pulse-free,
spallation-free, and single-use. Bags, filters, and tubing assemblies can now be self-driven, pre-
sterilized, and completely disposable. For the first time, an affordable, completely single-use fluid path
is within reach for your tangential flow, mixing, or bioreactor system!
The HemiTor™ pump system replaces the conventional peristaltic pump head for almost every pump
application.

HemiTor Operating Manual
2
Piranha Color Systems
Getting Started .....................................................................4
Overview ........................................................................................................5
Features …...................................................................................................... 5
User Instructions...................................................................6
Scale Calibration.............................................................................................7
System Setup, Weighing Point………………………………….…………………………………7
Pump Actions /Operating Modes………………………………….…………………………….9
Pump RPM continuous mode………………………………………………………….10
Flow / Duration ………………………………………………………………………………13
Weight Fill……………………………………………………………………………………….15
HemiTor Pump Cassette Installation….……….…….…..….…….…...….…...16
Technical References...........................................................17

HemiTor Operating Manual
3
Piranha Color Systems
110VAC in
RJ45
Ethernet Port
USB
USB-C for
programming only.
Factory use only.
Com port for
Flow Sensor
Com port for
Scale
Back panel
Power Switch

HemiTor Operating Manual
4
Piranha Color Systems
6
6
7
8
9
Getting Started
HemiTor Scale
Functions
1
Start
2
Stop
3
OK
4
Clear
5
Print
6
Gross Weight / Tare
7
Zero
8
Tare
9
Input: Alpha/Num/var
2
3
4
5
1

HemiTor Operating Manual
5
Piranha Color Systems
Overview
Thank you for using Piranha’s HemiTor Precision Pump for your important applications. The
HemiTor Precision Pump System delivers Precision, Versatility and Efficiency.
Piranha Color Systems proudly introduces the revolutionary HemiTor Precision Pump System. It
is a positive displacement fluid pump for precise dispensing of varying viscosity liquids as well
as for critical Life Sciences applications. The innovative pump system utilizes a novel single-use
cassette with internal dampening for precise fluid delivery and engineered for ease of use.
The HemiTor Precision Pump can be used for many different fluid transfer applications. The
basic functions are as follows:
•Accurately Dispenses by weight and volume
•Continuous Flow Rate mode
•Timed Flow Rate/Dispense mode
•Simple / universal tubing size
•Fluid Flow Pulse Dampening –Input and Output
•Unique software, easy to update for different customer requirements
Features
•The HemiTor Patented Single-Use cassette features internal pulse dampening,
minimizing product shear
•Fully programmable and customizable, advanced controller with ethernet, USB
and serial port connectivity.
•RPM operating range from 1 –1500 RPM
•Max. operating pressure 30 PSI
•Capable of pumping low to mid viscosity liquids
•Pump delivery flow rates from 0.025 mL/min to 4 L/min
•Easy to install, Single-Use pump cassette isolates the fluid path, eliminates cross
contamination and dampens pulsation.

HemiTor Operating Manual
6
Piranha Color Systems
User instructions
Scale Calibration
Turn on power switch on back of pump.
Wait for pump controller to start. Screen will show system booting.
To set and calibrate scale (make sure scale is connected)
Press Login:
Operating screen will appear

HemiTor Operating Manual
7
Piranha Color Systems
Scroll down to System Setup
Press OK
Scroll down to Weighing Point
Press OK
Press Calib
Press Modify

HemiTor Operating Manual
8
Piranha Color Systems
Set Max weight:
Press this key (alpha/num/sym) once to set Max d
enter 7000.0
Press OK
Press Twice to set Units.
Set to g(grams)
Press OK
Set Scale Interval:
Press OK
Scroll to 0.1g Press OK
Set Dead Load at:
Press by Load, Press OK

HemiTor Operating Manual
9
Piranha Color Systems
Set Max at:
Press by Load Press OK
Follow on screen instructions
place 5 kg weight on scale
enter weight number (e.g. 5kg)
press OK
Remove weight and return to case.
Press Save
The pump and scale have now been calibrated.
Operating Modes
Turn on power:
Controller will boot up, login screen will appear:
Press Login:
Table of contents
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual