Pilz PNOZ c1 User manual

PNOZ c1
Operating Manual-22197-EN-06
}Safety relays

Preface
This document is the original document.
All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made
for the user's internal purposes. Suggestions and comments for improving this documenta-
tion will be gratefully received.
Source code from third-party manufacturers or open source software has been used for
some components. The relevant licence information is available on the Internet on the Pilz
homepage.
Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®,
SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarks
of Pilz GmbH & Co. KG in some countries.
SD means Secure Digital

Contents
Operating Manual PNOZ c1
22197-EN-06 | 3
Introduction ............................................................................................................................4
Validity of documentation.......................................................................................................... 4
Using the documentation .......................................................................................................... 4
Definition of symbols................................................................................................................. 4
Safety ...................................................................................................................................... 5
Intended use ............................................................................................................................. 5
Safety regulations ..................................................................................................................... 5
Safety assessment ................................................................................................................... 5
Use of qualified personnel ........................................................................................................ 5
Warranty and liability ................................................................................................................ 6
Disposal .................................................................................................................................... 6
For your safety.......................................................................................................................... 6
Unit features ...........................................................................................................................6
Safety features ....................................................................................................................... 7
Block diagram/terminal configuration ................................................................................. 7
Function description ............................................................................................................. 7
Installation ..............................................................................................................................8
Wiring ......................................................................................................................................8
Connect cable with crimp connector......................................................................................... 9
Connect cable without crimp connector.................................................................................... 10
Disconnect cable ...................................................................................................................... 10
Preparing for operation ......................................................................................................... 11
Operation ................................................................................................................................12
Status indicators ....................................................................................................................... 12
Error indicators ......................................................................................................................... 13
Faults - malfunctions ............................................................................................................. 13
Dimensions in mm .................................................................................................................13
Technical details ....................................................................................................................14
Safety characteristic data ......................................................................................................... 18
Supplementary data ..............................................................................................................18
Service life graph ...................................................................................................................... 19
Order reference ......................................................................................................................20
EC Declaration of Conformity ............................................................................................... 20

PNOZ c1
Operating Manual PNOZ c1
22197-EN-06 | 4
Introduction
Validity of documentation
This documentation is valid for the product PNOZ c1. It is valid until new documentation is
published.
This operating manual explains the function and operation, describes the installation and
provides guidelines on how to connect the product.
Using the documentation
This document is intended for instruction. Only install and commission the product if you
have read and understood this document. The document should be retained for future ref-
erence.
Definition of symbols
Information that is particularly important is identified as follows:
DANGER!
This warning must be heeded! It warns of a hazardous situation that poses
an immediate threat of serious injury and death and indicates preventive
measures that can be taken.
WARNING!
This warning must be heeded! It warns of a hazardous situation that could
lead to serious injury and death and indicates preventive measures that can
be taken.
CAUTION!
This refers to a hazard that can lead to a less serious or minor injury plus
material damage, and also provides information on preventive measures
that can be taken.
NOTICE
This describes a situation in which the product or devices could be dam-
aged and also provides information on preventive measures that can be
taken. It also highlights areas within the text that are of particular import-
ance.

PNOZ c1
Operating Manual PNOZ c1
22197-EN-06 | 5
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
Safety
Intended use
The safety relay provides a safety-related interruption of a safety circuit.
The safety relay meets the requirements of EN 60947-5-1 and EN 60204-1 and may be
used in applications with:
}E-STOP pushbuttons
}Safety gates
The following is deemed improper use in particular
}Any component, technical or electrical modification to the product,
}Use of the product outside the areas described in this manual,
}Use of the product outside the technical details (see Technical details [ 14]).
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.
Safety regulations
Safety assessment
Before using a device, a safety assessment in accordance with the Machinery Directive is
required.
The product as an individual component fulfils the functional safety requirements in accord-
ance with EN ISO 13849 and EN 62061. However, this does not guarantee the functional
safety of the overall plant/machine. To achieve the relevant safety level of the overall plant/
machine’s required safety functions, each safety function needs to be considered separ-
ately.
Use of qualified personnel
The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by persons who are competent to do so.

PNOZ c1
Operating Manual PNOZ c1
22197-EN-06 | 6
A competent person is a qualified and knowledgeable person who, because of their train-
ing, experience and current professional activity, has the specialist knowledge required. To
be able to inspect, assess and operate devices, systems and machines, the person has to
be informed of the state of the art and the applicable national, European and international
laws, directives and standards.
It is the company’s responsibility only to employ personnel who
}Are familiar with the basic regulations concerning health and safety / accident prevention,
}Have read and understood the information provided in the section entitled Safety
}Have a good knowledge of the generic and specialist standards applicable to the specific
application.
Warranty and liability
All claims to warranty and liability will be rendered invalid if
}The product was used contrary to the purpose for which it is intended,
}Damage can be attributed to not having followed the guidelines in the manual,
}Operating personnel are not suitably qualified,
}Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).
Disposal
}In safety-related applications, please comply with the mission time TM in the safety-related
characteristic data.
}When decommissioning, please comply with local regulations regarding the disposal of
electronic devices (e.g. Electrical and Electronic Equipment Act).
For your safety
The unit meets all the necessary conditions for safe operation. However, please note the
following:
}Note for overvoltage category III: If voltages higher than low voltage (>50 VAC or >120
VDC) are present on the unit, connected control elements and sensors must have a rated
insulation voltage of at least 250 V.
Unit features
}Positive-guided relay outputs:
– 3 safety contacts (N/O), instantaneous
– 1 auxiliary contact (N/C), instantaneous
}Connection options for:
– Emergency stop pushbuttons
– Safety gate limit switches
– Reset buttons
– PSENmech, PSENmag

PNOZ c1
Operating Manual PNOZ c1
22197-EN-06 | 7
}LED for:
– Supply voltage
– Switch status channel 1
– Switch status channel 2
Safety features
The relay meets the following safety requirements:
}The circuit is redundant with built-in self-monitoring.
}The safety function remains effective in the case of a component failure.
}The correct opening and closing of the safety function relays is tested automatically in
each on-off cycle.
Block diagram/terminal configuration
InputInput
A1 A2 S21 S22
=
Power
Start
S11 S12
=
K1
K2
13 23 33
24 34
14
41
42
*
S33 S34
14
24
34
42
41
33
23
13
S34
S33
S22
S21
S12
S11
A2
A1
PNOZ c1
Ch. 1
Power
Ch. 2
* Insulation from non-marked area: Safe separation (overvoltage category III),
Insulation between relay contacts: basic insulation (overvoltage category III), safe separa-
tion (overvoltage category II)
Function description
When the supply voltage is supplied, the "POWER" LED illuminates. The unit is ready for
operation when the start circuit is closed.
}Input circuits closed (e.g. the E-STOP button is not pressed): The safety contacts are
closed and the auxiliary contact is open.
}Input circuit open (e.g. E-STOP operated): The safety contacts are open and the auxiliary
contact is closed.

PNOZ c1
Operating Manual PNOZ c1
22197-EN-06 | 8
}Dual-channel operation with detection of shorts across contacts: redundant input circuit,
detects
– earth faults in the start and input circuit,
– shorts between contacts in the input circuit.
}Automatic start: Unit is active once the input circuit has been closed.
}Manual start Unit is active once the input circuit is closed and then the start circuit is
closed.
}Increase in the number of available contacts by connecting contact expandsion modules
or external contactors/relays.
Installation
}The unit should be installed in a control cabinet with a protection type of at least IP54.
}Use the notch on the rear of the unit to attach it to a DIN rail.
}Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing ele-
ment (e.g. retaining bracket or an end angle).
Wiring
Please note:
}Information given in the "Technical details" must be followed.
}Outputs 13-14, 23-24, 33-34 are safety contacts; output 41-42 is an auxiliary contact (e.g.
for display).
}Auxiliary contact 41-42 shouldnot be used for safety circuits!
}To prevent contact welding, a fuse should be connected before the output contacts (see
see technical details [ 14]).
}Calculation of the max. cable length lmax in the input circuit:
Rlmax
Rl / km
Imax =
Rlmax = max. overall cable resistance (see see technical details [ 14])
Rl / km = cable resistance/km
}Use copper wiring with a temperature stability of 60/75 °C.
}To prevent EMC interferences (particularly common-mode interferences) the measures
described in EN60204-1 must be executed. This includes the separate routing of cables
of the control circuits (input, start and feedback loop) from other cables for energy trans-
mission or the shielding of cables, for example.
}Sufficient fuse protection must be provided on all output contacts with capacitive and in-
ductive loads.
}Do not switch low currents using contacts that have been used previously with high cur-
rents.
}When connecting magnetically operated, reed proximity switches, ensure that the max.
peak inrush current (on the input circuit) does not overload the proximity switch.
}The power supply must comply with the regulations for extra low voltages with protective
electrical separation (SELV, PELV) in accordance with VDE 0100, Part 410.

PNOZ c1
Operating Manual PNOZ c1
22197-EN-06 | 9
Important for detection of shorts across contacts:
As this function for detecting shorts across contacts is not failsafe, it is tested by Pilz during
the final control check. If there is a danger of exceeding the cable runs, we recommend the
following test after the installation of the device:
1. Unit ready for operation (output contacts closed)
2. Short circuit the test terminals S12, S22 for detecting shorts across the inputs.
3. The unit's fuse must be triggered and the output contacts must open. Cable lengths in
the scale of the maximum length can delay the fuse triggering for up to 2 minutes.
4. Reset the fuse: remove the short circuit and switch off the supply voltage for approx. 1
minute.
Connect cable with crimp connector
}Strip the cable [1] and apply a crimp connector.
}Insert the stripped cable with the crimp connector applied into the terminal point [2] [3] as
far as it will go.
NOTICE
Do not use a tool to connect the cable.
[1] [2] [3]
10 mm
Fig.: Connect cable with crimp connector

PNOZ c1
Operating Manual PNOZ c1
22197-EN-06 | 10
Connect cable without crimp connector
}Strip the cable [1].
}Using the screwdriver, press the actuator button [2] and insert the stripped cable into the
terminal point [2] [3] as far as it will go.
We recommend you use a screw driver with a 0.4 x 2.5 mm (DIN 5264) blade!
[1] [2] [3]
10 mm
Fig.: Connect cable without crimp connector
Disconnect cable
We recommend you use a screw driver with a 0.4 x 2.5 mm (DIN 5264) blade!
}Using the screwdriver, press the actuator button and pull the cable out of the terminal
point [4].
[4]
Fig.: Disconnect cable
Other manuals for PNOZ c1
1
Table of contents
Other Pilz Relay manuals

Pilz
Pilz PNOZ pe1p User manual

Pilz
Pilz PZE X4VP User manual

Pilz
Pilz PNOZ X Series User manual

Pilz
Pilz PU3Z User manual

Pilz
Pilz PNOZ s7.1 User manual

Pilz
Pilz 22 772-04 User manual

Pilz
Pilz PZE X4V8 User manual

Pilz
Pilz PNOZ X Series User manual

Pilz
Pilz PNOZ X1 User manual

Pilz
Pilz PNOZ XV3.3P User manual