Figure 9: Magna extraction port cover plate and 4-inch spigot
Figure 10: Magna back view detail on port cover plate and 4 inch spigot
6. Power requirements
- Liquid Crystal Magna requires a mains power supply with a voltage
of 100 VAC - 240 VAC and a frequency of 50 Hz - 60 Hz.
- It has a power consumption of 1300 W. It will draw a current of 7.0
A when connected to a 240 VAC supply, or 13.5 A when connected to
a 100 VAC supply.
- Only connect Liquid Crystal Magna to the mains socket using the
power cable supplied.
- The printer power socket is on the back of the machine, at the right
side (Figure 10).
- Always plug the power cable into the mains socket and the printer
before switching on the power at the mains socket.
- Similarly, always switch o the power at the mains socket before
unplugging the power cable from either the printer or the mains socket.
- The power button is on the front of the machine, at the right side
(Figure 11).
- In case of emergency you can switch o the printer by pushing the
power button.
5. Extraction
Liquid Crystal Magna has an extraction port on the back, with a
cover plate. The cover plate is attached by four screws (Figure
9). A 4-inch spigot is supplied in the accessory box. This can be
attached to the back of the machine if the cover plate is removed.
Re-use the four screws to secure the spigot. This will allow you to
connect 4-inch ducting to the printer.
Extraction is recommended if Magna is operated in a conned or
poorly ventilated space.
It should not be necessary in most cases. The fumes from the
printing process are not harmful, but the smell can be unpleasant.
The volume of air inside the printer is approximately 320 litres (0.32
m3). A maximum of 2 air changes per minute should be used. This
corresponds to a ow rate of 640 litres per minute or 38 m3 per hour.
Using a higher ow rate will cause excessive cooling of the resin
which may aect print performance. It will also increase the noise
level and may draw dust into the printer.
In cases where a higher extraction ow rate must be used, most of
the fumes can be removed from Magna in just a few minutes. After
each print is nished, turn on the extraction for a short period before
opening the printer door
9 10
POWER
SOCKET
USB SOCKET
(FOR WIFI DONGLE)
RJ45
NETWORK
SOCKET