Phonic ICON 300 User manual

ICON 300
ICON 700
ICON 700
Contractor Power Amplifier
English

1. Read these instructions before operating this
apparatus.
2. Keep these instructions for future reference.
3. Heed all warnings to ensure safe operation.
4. Follow all instructions provided in this document.
5. Do not use this apparatus near water or in locations
where condensation may occur.
6. Clean only with dry cloth. Do not use aerosol or liquid
cleaners. Unplug this apparatus before cleaning.
7. Do not block any of the ventilation openings. Install
in accordance with the manufacturer
’
s instructions.
8. Do not install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug
has two blades and a third grounding prong. The wide
blade or the third prong is provided for your safety. If
the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or
pinched particularly at plug, convenience receptacles,
and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the
manufacturer.
12. Use only with a cart, stand, tripod, bracket, or
table specified by the manufacturer, or sold with
the apparatus. When a cart is used, use caution
when moving the cart/apparatus
combination to avoid injury from tip-
over.
13. Unplug this apparatus during lighting
storms or when unused for long
periods of time.
14. Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord or
plug is damaged, liquid has been spilled or objects
have fallen into the apparatus, the apparatus has
been exposed to rain or moisture, does not operate
normally, or has been dropped.
IMPORTANT SAFETY INSTRUCTIONS
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED PERSONNEL
The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated
“
dangerous voltage
”
within the
product
’
s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is in-
tended to alert the user to the presence of important operat-
ing and maintenance (servicing) instructions in the literature
accompanying the appliance.
WARNING: To reduce the risk of fire or electric shock, do
not expose this apparatus to rain or moisture.
CAUTION: Use of controls or adjustments or performance
of procedures other than those specified may result in
hazardous radiation exposure.
The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases,
shall be placed on the apparatus. The MAINS plug is used as the disconnect device, the disconnect device shall
remain readily operable.
Warning: the user shall not place this apparatus in the confined area during the operation so that the mains switch
can be easily accessible.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN

Contractor Power Amplifier
ICON 300/700
INTRODUCTION…………………………………………………………...…...........……........……..4
FEATURES………………………………………………………….…………....................................4
PRECAUTIONS………………………………………………………….………….............................4
ABOUT THIS MANUAL…………………………………………….…………...................................4
FRONT PANEL DESCRIPTION…………………………………………….…………......................5
REAR PANEL DESCRIPTION…………………………………………….………….........................6
BALANCE BARRIER STRIP INPUT CONNECTIONS……………………….………..…...............7
BARRIER STRIP OUTPUT CONNECTIONS……………………………………….…..……….......7
AUDIO TRANSFORMER OUTPUTS…………………………………………….……….….............8
PARALLEL MONO CONFIGURATION…………………………………………….……….…..........9
SPECIFICATIONS..…………………………………………….………….......................................10
BLOCK DIAGRAM…………………………………………….………….........................................11
Phonic reserves the right to improve or alter any information supplied within this document without prior notice.
V1.1 10/10, 2005
TABLE OF CONTENTS

4 ICON 300/700
INTRODUCTION
Congratulations on your purchase of the Phonic
Icon 300 or 700 power amplifier. The Icon Series is
a line of professional power amplifiers specifically
designed for contracting application. These two
models each has independent channels and is
available for driving 200V, 140V, 100V, 70V, 50V or
25V "constant voltage" lines. Each channel has its
own power transformer (toroidal type) secondary
to provide maximum audio separation (minimum
sound leakage) between two channels, minimizing
interaction that can otherwise occur on amplifiers
with a common power supply.
FEATURES
Automatic dual-speed, high efficiency fan
cooling
Rear panel detented gain controls for
security and resetability
Stereo, bridge or parallel operating
modes
XLR and barrier strip inputs
XLR in and outs for multiple amplifier
operation & easy signal pass-through
Fully short-circuit, temperature and DC
offset protection
Barrier strip connection determines output
mode - 25V, 70V, 100V and direct outputs
available simultaneously
Toroidal output transformers provide full
electrical isolation and meet worldwide
safety agency approval
Built-in 45 Hz subsonic filter prevents
speaker transformer saturation with
minimal effect on program material
Power-up muting
PRECAUTIONS
1. When first powering up the amp, keep the
amplifier gain controls all the off, in order to
block potentially damaging or annoying sounds
caused by defective cables or hookups. When
turning up the gain, do it gradually, until normal
operation is verified. These precautions are
necessary with all high-power amplifiers,
since they have enough power to blow most
speakers in abnormal situations.
2. Check the AV Voltage before connecting the
AC plug
3. Speaker Output Shock Hazard! The Icon
300 and 700 amps are capable of producing
hazardous output voltages. To avoid electrical
shock, make sure the cover is in place over
the output terminals, and do not touch any
exposed speaker wiring while the amplifier is
operating.
ABOUT THIS MANUAL
Please be reminded that a power amplifier is a
high-current, high-power device and should be
treated with respect and care. Please read this
manual before connecting and operating your unit,
and file it in a safe place for future reference.

5ICON 300/700
FRONT PANEL DESCRIPTION
1. Power Switch
The power ON/OFF switch with an LED indicator.
2. Protect LED Indicator
The Icon 300/700 features several types of
protection to prevent damage to the circuitry during
turn-on or fault conditions. If the LEDs light up, this
indicates that one of the various protections is
safeguarding the different sections of the amplifier
and in these cases, the power output is normally
switched off until normal operating conditions are
restored.
Loudspeaker protection: the power-
on protection relay prevents damaging
thumps to the speakers as the power
comes on. When the amp is switched
on, the protect LED will light for a few
seconds, and then go out, indicating that
the relay has closed.
Thermal protection on the heat sink: If
the amp overheats, thermal shutdown
protects the circuitry until the temperature
is reduced to a safe level.
Short circuit protection: The Protect LED
Indicator will also light up if the speaker
terminals are short-circuited, or the
impedance of the load is too low. In these
circumstances, the Protect LED will stay
on until the fault conditions are rectified.
Some protection situations require the amplifier
to be switched off and then back on for normal
operating conditions to be restored.
3. Clip LED Indicator (Icon 300)
The LEDs light up at clipping status, whenever any
conditions occur that could cause problems for the
amp, such as an out-of-spec load and waveform
distortion. Because of the Icon's ability to enter
and exit clipping with as few audible artifacts as
possible, you may not hear any distortion even if
the indicator flashes. In general, a few flashes every
now and then will not be a problem. However, if the
LEDs flash often or remain on for any extended
period of time, then turn down the volume controls
to reduce the signal level going to the Icon amp. If
this doesn't solve the problem, check your output
cables and speakers.
4.Signal “Status” LED Indicator
Each channel of the Icon 300/700 features a signal
LED to show that there is an audio signal at the
input to the channel. The threshold for the indicator
is -26dB, which should be enough to avoid noise
triggering the LED.
5. Limit LED Indicator (Icon 700)
The Icon 700 has a built-in limiter on each channel
to prevent clipping. Should the signal reach a level
high enough to cause clipping (ie. output power is
over 400W per channel), the limiter momentarily
reduces the input signal level, just enough to
prevent it. The limit LED lights whenever this
occurs.

6 ICON 300/700
REAR PANEL DESCRIPTION
6. Gain Controls
These two knobs and the level controls for channels
one and two respectively. Turning clockwise
will increase its gain and counter clockwise will
decrease its gain. Please always power-up with
the volume all the way down, and increase the
volume slowly to make sure that no conditions
exist which could annoy your audience or harm
your speakers.
7. CH1/CH2 Inputs (XLR Connectors)
These inputs are provided for making balanced
connection to mixers, preamps, etc. The XLR
inputs are wired as per the following convention:
8. Balanced Barrier Strip Inputs
These connection points provide the best option for
permanent or long-term installation. Connections
should be screwed down tight to exclude oxygen,
and care should be taken to avoid loose strands of
wire that may cause short circuits.
9. CH1/CH2 Parallel Pass Through XLR
Connectors
These XLR output connectors are provided
for parallel connection to another Icon or other
amplifier.
10. Stereo/Parallel/Bridge Switch
In Stereo operation, two separate signals are
treated separately by channels 1 and 2 of the
amplifiers.
In Parallel operation, one signal is treated by
bother channel 1 and 2 of the amplifier. In other
words, a signal connected to Input CH1 (6) or CH2
(7) is sent to both Output CH1 (10) and CH2 (11).
In Bridge operation, both channels are configured
to drive a single load with a single signal to CH1
(only CH1 is operative, and CH2 input must be
vacant) at twice the power.
This switch should only be used when the
Amplifier is off; otherwise the speakers'
components could be damaged.
11. Direct Output Connectors, CH1/CH2
These are barrier strips to connect low impedance
speakers. Spade lugs and bare wires should both
be screwed down tight to exclude oxygen, and care
should be taken to avoid loose strands of wire that
may cause short circuits.
12. Audio Transformer Outputs, CH1/CH2
These are barrier strips to connect distributed line
(25V, 70V, 100V, 140V and 200V). Spade lugs
and bare wires should both be screwed down tight
to exclude oxygen, and care should be taken to
avoid loose strands of wire that may cause short
circuits.

7ICON 300/700
Balance Barrier Strip Input
Connections
Balanced connection - Attach as shown. Connect
the (+) wire and ground wire to terminal pins as
marked.
Unbalanced connection - Attach input signal
wires as shown. Use the non-inverting (+) input
and the ground terminals of the header, and also
connect a wire jumper between the inverting (-)
input and the ground terminal. The wire jumper will
prevent a reduction in gain caused by a floating
unbalanced input.
Input sensitivities - Audio signals of these levels
will produce full rated output power at 8 ohms.
ICON 300 - 1.02Volts (+2.4dBu)
ICON 700 - 1.02Volts (+2.4dBu)
Barrier Strip Output Connections
Barrier strips located on the rear panel allow speaker
cable connections to the amplifier output. See the
diagrams for details on connecting speakers and/
or distributed (23-, 70-, or 100-volt) lines. Insulated
connectors of the type shown are recommended.
Always make sure the amplifier is turned off
before you change any output connections.
Loose screw terminals, insert wire connectors
under screws. Tighten screw terminals.
Direct low impedance:
Output connection for Icon 300/700,
bridge mono mode
Output connection for Icon 300/700,
direct low impedance

8 ICON 300/700
Bridge Mono Configuration for Direct Outputs
1. Set into bridge mode
2. Connect the signal to channel 1's input
only. Do not connect an input signal to
channel 2.
3. Use on channel 1's gain control to set the
level. Both channels' signal and clip indicators
should flash identically when the amplifier is
operating.
Audio Transformer Outputs
Make sure the sum of the power settings of all
the speakers does not exceed the power rating of
the amplifier. It is a good practice to allow a 20%
safety margin. For example, if the amplifier has a
power rating of 300W, it is always a good idea to
make sure the sum of the loudspeaker loads on the
distributed line is 240W or less.
25 volt line output connection
50 volt line output connection
100 volt line output connection
Bridge Mono Configuration for Audio
Transformer Outputs
1. For driving 140V or 200V distributed lines, the
amplifier must be set into bridge mono mode.
2. Connect the signal to channel 1's input
only. Do not connect an input signal to
channel 2.
3. Use only channel 1's gain control to set the
level. Both channels signal and clip indicators
should flash identically when the amplifier is
operating.
140 volt line output connection,
bridge mono mode
200 volt line output connection,
bridge mono mode

9ICON 300/700
Parallel Mono Configuration
The "Parallel mode" ties the two channel inputs
together so that both are driven by the same
signal, without the need for external jumpers or
wiring. After the inputs, both channels operate
independently. Though they carry the same signal,
their gain controls affect only their respective
channels, which must be used separately. Please
refer to the previous Rear Panel Description. Never
parallel the speaker outputs.
Low-Impedance and Distributed Speakers on
Icon Amplifiers
If your application calls for connection of an 8 ohm
speaker and a distributed line to the same amplifier
channel, the Icon 300 and Icon 700 are among
the very few amplifiers that can do that. However,
since most of the audio power is drawn by the
direct-connected speaker, you must derate the
distributed line; and the distributed line should have
a total power load of no more than one-fourth of the
amplifiers normal distributed line power rating.
Computing maximum allowable distributed
line load with a known low-impedance
load
MaxTOP = [MaxRatedPL - ((2 x MaxRatedPL)/
Impedance)]/2
MaxTOP is the sum of the power taps of the
speakers connected to the Audio Transformer
outputs.
MaxRatedPL is the maximum rated power of the
amplifier into a two ohm load.
Impedance is the load impedance connected to the
direct outputs.
Example: One channel of an Icon 700 has an 8-
ohm load connected to the Direct (low impedance)
output. Then the maximum power left available
to drive a distributed line is: MaxTOP = [550-
((2x550/8)/2)] = 206 Watts

10 ICON 300/700
Specifications
ICON 300 ICON 700
Direct Power Out
Max.average power at 45Hz-20kHz
With 0.1% THD
8 ohm 120W×2 240W×2
4 ohm 200W×2 400W×2
2 ohm,1kHz,1%THD 300W×2 550W×2
Bridged mono 8 ohm,1kHz,1%THD 420W 850W
Bridged mono 4 ohm,1kHz,1%THD 540W 1100W
Isolated Constant Voitage Out
200V or 140V Bridege 300W 700W
100V or 70V 150W×2 350W×2
25V 120W 280W×2
Frequency Response
Direct Outputs (+0/-2dB) 50Hz-50kHz
Isolated Outputs (+0/-2dB) 50Hz-16kHz
Total Harmonic Distortion <0.05 <0.05
Sensitivity (fro full output) 1.02V 1.02V
Voitage Gain 28dB 32dB
Input Impedance
Balanced/Unbalanced 20k/10k ohm
Damping Factor >200(direct output)
S/N Ratio Less than 100dB below rated output (20Hz-20kHz)
Protection Circuits
● Output offset voitage protection
● Heat sink overheat protection
● Transformer overheat protection
● Load shorting protection
● Power on/off protection
Controls
Front Panel/ Power Switch/
Rear Panel Ch1 & Ch2 gain controls (41 click); Parallel/Stereo/
Bridge switch
Connectors
Input/ XLR jack ×2,Barrier strip ×1/
Output Covered Barrier strip ×2;heavy-duty binding post
Cooling One dual speed fan
Indicators
Clip:Red Signal:Green
Protect:Yellow Power:
Red
Limit:Red Signal:Green
Protect:Yellow Power:
Red
Dimensions(H×W×D) 132×480×428mm 132×480×428mm
Net Weight 24.3KG 24.3KG
Shipping Weight 26.0KG 26.KG
Other manuals for ICON 300
1
This manual suits for next models
1
Table of contents
Other Phonic Amplifier manuals

Phonic
Phonic MAX 860 plus User manual

Phonic
Phonic MAR1 User manual

Phonic
Phonic MAX 250 User manual

Phonic
Phonic T8300 User manual

Phonic
Phonic PHA 8800 User manual

Phonic
Phonic XP6000 User manual

Phonic
Phonic MAX 3500 User manual

Phonic
Phonic ZA100 User manual

Phonic
Phonic XP1000 User manual

Phonic
Phonic iAMP 1620 User manual

Phonic
Phonic MAX 1000 User manual

Phonic
Phonic MAX 250 User manual

Phonic
Phonic MAX 1000 User manual

Phonic
Phonic iAMP3020DSP User manual

Phonic
Phonic XP 2000 User manual

Phonic
Phonic ZA200B User manual

Phonic
Phonic MAX 250 User manual

Phonic
Phonic XP 600 User manual

Phonic
Phonic CA35 User manual

Phonic
Phonic ZAIOO User manual