Perle IOLAN SDG4 LA/LE Manual

IOLAN SDG4 LA/LE Hardware Installation Guide
Updated: September 2019
Version A.1.09.01.2019
Document Part#:5500411-10(Rev. C)
www.perle.com

IOLAN SDG4 LA/LE Hardware Installation Guide
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS GUIDE ARE SUBJECT TO CHANGE
WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS GUIDE ARE BELIEVED TO BE
ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE
FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in
accordance with this hardware guide may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own
expense.
Modifications to this product not authorized by Perle could void the FCC approval and negate your authority to operate the product.
Perle reserves the right to make changes without further notice, to any products to improve reliability, function, or design.
Perle, the Perle logo, and IOLAN SDG4 LA and IOLAN SDG4 LE are trademarks of Perle Systems Limited.
©2019. Perle Systems Limited.

Table of Contents
Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
IOLAN SDG4 L (Top View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
IOLAN SDG4 L (Side Views) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Ethernet and Serial Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Button/Switch Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Ethernet Port Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Connecting the Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Connecting the Serial Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Connecting Data Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Resetting the IOLAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Resetting the IOLAN to Factory Default Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Configuring the IOLAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Appendix A - Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Appendix B - Mechanical Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Appendix C - Sample Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Appendix D - Cabling and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Appendix E - IOLAN Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Contacting Perle Systems Limited . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

2
IOLAN SDG4 LA/LE Hardware Installation Guide
Hardware
Preface
Audience
This guide is for the network or computer technician responsible for installing the Perle
IOLAN SDG4 LA/LE. Familiarity with the concepts and terminology of Ethernet and local
area networks is required.
Purpose
This document describes the hardware and physical characteristics of the Perle IOLAN
SDG4 LA/LE. It covers hardware features as well as installation and operation of the
IOLAN. This document does not cover how to configure your Perle IOLAN SDG4 LA/LE.
Information to configure your Perle IOLAN SDG4 LA/LE can be found in the IOLAN Secure
User’s Guide.
Document Conventions
This document contains the following conventions:
Most text is presented in the typeface used in this paragraph. Other typefaces are used
to help you identify certain types of information. The other typefaces are:
Note: Means reader take note: notes contain helpful suggestions.
Caution: Means reader be careful. In this situation, you might perform an action that
could result in equipment damage or loss of data.
Warning: IMPORTANT SAFETY INSTRUCTIONS
Means danger. You are in a situation that could cause bodily injury. Before you work on
any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Only qualified personnel should con-
nect power to this unit.

IOLAN SDG4 LA/LE Hardware Installation Guide
Overview
This guide provides information on installing and doing the initial configuration on the
IOLAN SDG4 LA/LE unit.
The IOLAN SDG4 LA/LE comes in two basic flavors;
IOLAN SDG4 LA - Four RJ45 serial ports and a North American Cellular module.
IOLAN SDG4 LE - Four RJ45 serial ports and a European Cellular module.
This guide refers to these models generically as the IOLAN SDG4 L.
IOLAN SDG4 L (Top View)

IOLAN SDG4 LA/LE Hardware Installation Guide
IOLAN SDG4 L (Side Views)
Ethernet and Serial Ports
10/100/1000Base-T Port
The Ethernet port provides the standard Gigabit Ethernet interface speeds of 10/100/
1000 Mbps through twisted pair (UTP) cables of up to 100 meters (328ft) in length.
Serial / Console Port
The unit has four RJ45 ports. All ports can be used to connect a serial device. When used
to connect a serial device, the ports can operate in EIA-232, EIA-422 or EIA-485 mode.
When port 1 is used to connect a console, the port can be used to fully configure and
manage the IOLAN. For details on how to connect to the serial ports see Connecting the
Serial Port .
For details on the serial port pin-out see Appendix D - Cabling and Connectors
Button/Switch Functions
Reset Button
The inset “Reset” button will reboot the IOLAN if pushed in and released quickly. It will
reset the IOLAN to factory defaults if pushed in and held for more than three seconds.
For more details on the operation of the Reset button see “Resetting the IOLAN ”
Console / Serial DIP Switch
Serial port 1 can act as a console port or a serial port. The mode of operation is deter-
mined by the position of the “console/serial port” DIP switch. The DIP is set in the fac-
tory to serial (up position). Unless you plan to attach a console to the IOLAN, leave the
DIP switch in the serial position. In console mode, this port can be used to provide access
to the IOLAN management function using the industry standard CLI command set (see
Console Port Mode ).
See the IOLAN Command Line Interface Reference Guide for a complete set of the com-
mands available via the console.

IOLAN SDG4 LA/LE Hardware Installation Guide
LED Indicators
Power/Ready
Link 10/100/1000
WWAN
Signal strength
State Description
Green - solid System Ready
Green - flashing System is booting or dip
switch is in console mode
Off Error condition
State Description
Green 1000 Mbps (flashes with
activity)
Green/Amber 100 Mbps (flashes with
activity)
Amber 10 Mbps (flashes with
activity)
Off No LAN connection
State Description
Green-solid A wireless connection has
been established / activity
Green-flashing Data is being transmitted
over the wireless network
Off No wireless connection
established
State Description
2 X Amber/
3 X Green
This is a progressive signal. If
only the orange LEDs are lit,
this would indicate a weak
signal. Advancement of
green LEDs indicate a
stronger signal strength

IOLAN SDG4 LA/LE Hardware Installation Guide
Ethernet Port Status Indicators
Port Link / Speed
State Description
Green 1000 Mbps (flashes with
activity)
Green/Amber 100 Mbps (flashes with
activity)
Amber 10 Mbps (flashes with
activity)
Off No LAN connection

IOLAN SDG4 LA/LE Hardware Installation Guide
Installation
General Cautions and Warnings
Warning: Power sources must be off prior to beginning the power connection steps.
Read the installation instructions before you connect the unit to its power source.
Warning: Ensure that the voltage and current ratings of the intended power source are
appropriate for the IOLAN as indicated on the product label.
Warning: Ensure that the installation and electrical wiring of the equipment is performed
by trained and qualified personnel and that the installation complies with all local and
national electrical codes.
Warning: The working voltage inputs are designed for operation with Safety extra low
Voltage (SELV). Connect only to SELV circuits with voltage restrictions in line with IEC/EN
60950-1:2005 (2nd Edition) + A1:2009 and EN 60950-1: 2006 + A11:2009
Warning: If this equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
Warning: Transient protection shall be provided that is set at a level not exceeding 140%
of the peak rated voltage value at the supply terminals to the equipment.

IOLAN SDG4 LA/LE Hardware Installation Guide
Connecting the Hardware
Power
Either the barrel or TB (Terminal Block) can be used to power the SDG4 L.
Connecting the barrel connector
Plug the power adapter into a power socket and connect the barrel connector end into
the IOLAN SDG2 L. The IOLAN will perform a power up sequence. The Power/Ready LED
should show a solid green. See LED Indicators for power up sequence.
Connecting the terminal block connector
1. Ensure power is NOT applied to the wires prior to connection.
2. On each end wire (12-20 AWG), remove the insulation from the copper wire 5 mm (3/
16 of an inch).
3. Loosen the left screw on the top of the terminal connector block, then insert your
positive (+) wire into the left terminal and screw it down tight (.51Nm torque).
Loosen the right screw on the top of the terminal connector block, then insert your
negative (-) wire into the right terminal and screw it down tight (.51Nm torque).
4. Re-insert the terminal block connector if removed.
Grounding and Power Cord Relief clip
If your installation requires additional grounding, follow this procedure.
Grounding the chassis requires the following items:
• One grounding lug (not provided)
• One 12AWG wire (not provided)
Follow the manufacturers instructions for attaching the ground wire to the grounding
lug.
1. Attach the grounding lug to the chassis and secure with the grounding screw
provided. See Figure 1.
2. Attach the power cord relief clip as shown in Figure 2.
Table of contents
Other Perle Network Router manuals

Perle
Perle 1700 Instruction Manual

Perle
Perle PERLE P850 Instruction Manual

Perle
Perle PERLE P850 Instruction Manual

Perle
Perle IRG5520 Series User manual

Perle
Perle IRG7440 User manual

Perle
Perle P2600 Instruction Manual

Perle
Perle IOLAN SDG4 P/STG4 P Manual

Perle
Perle IOLAN SCG Manual

Perle
Perle IRG5410 Series User manual

Perle
Perle LINKSTREAM User manual

Perle
Perle P840 User manual

Perle
Perle IOLAN SDG2 LA/LE Manual

Perle
Perle IOLAN SDS User manual

Perle
Perle IOLINK-520 Instruction Manual

Perle
Perle P841 User manual

Perle
Perle IRG5410 Series Manual

Perle
Perle IOLAN STG8 User manual

Perle
Perle P1705 Instruction Manual

Perle
Perle IRG5140+ Manual

Perle
Perle PERLE P850 User manual