NY Wholesale DT608 Series User manual

USER MANUAL
DT-ENG-608-V1 / 201708
• Please read this manual carefully to ensure safe and correct operation.
• Keep this manual well for future reference.
RF CARD
EP608-S12DT608/ID/FE-S8 DT60C-S8
DT608 Series
2 WIRE SYSTEM
Fisheye door station with proximity access control

CONTENTS
PARTS AND FUNCTIONS ..................................................................................... 3
Part Names............................................................................................................. 3
Mounting................................................................................................................. 3
Terminal Description............................................................................................... 4
BASIC FUNCTIONS .............................................................................................. 5
Unlock Operations.................................................................................................. 5
Fisheye Camera ..................................................................................................... 5
External Motion Detection ...................................................................................... 5
SETUP INSTRUCTIONS........................................................................................ 6
Functions Setting Up .............................................................................................. 6
Setting Door Station Address ................................................................................. 7
Setting Door Station Calling Mode ......................................................................... 7
Setting Camera N/P Standard................................................................................ 9
Setting Prompt Voice.............................................................................................. 9
Setting Prompt Voice Volume................................................................................ 10
Setting Unlock Mode ............................................................................................. 10
Setting Unlock Time............................................................................................... 11
Setting Nameplate Illumination Mode.................................................................... 11
Setting Night View LED Illumination Mode............................................................ 12
Setting Ring-back Tone ......................................................................................... 12
Setting Image Display Mode.................................................................................. 13
RAINY_COVER Congure .................................................................................... 14
Registering ID Card............................................................................................... 15
Restore To Default................................................................................................. 17
WIRING ................................................................................................................. 18
Connecting Electric Lock....................................................................................... 18
As The Villa System Door Stations........................................................................ 19
As The Apartment System Door Stations.............................................................. 20
APPENDIX ............................................................................................................ 21
Precautions............................................................................................................ 21
Specication .......................................................................................................... 21
Cables and Requirments....................................................................................... 22

-3-
Part Names
PARTS AND FUNCTIONS
[9]
[10]
[11]
[12]
[8]
[7]
[6]
[5]
[1]
[3]
[4]
[2]
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Speaker
[7] Night view LED
[8] Camera lens
[9] Rainy cover
[10] Mounting hook
[11] Connection port
[12] External key module
Mounting
1 2 3 4 5
Rainy cover
The distance between
the top of main unit
and rain cover should
be not less than 3mm.
Main unit
≥3mm
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
Rainy cover
Main unit
1. Drill holes in the wall to match the size of screw stoppers, then attach the rainy cover to the
wall.
2. Connect the cable correctly, and attach the main unit to the rainy cover. The distance between
the top of main unit and rain cover should be not less than 3mm.
The installation height is suggested to 145~160cm.

-4-
PARTS AND FUNCTIONS
Lock Control Jumper: To select the lock type.
3P Connect Port: 1. If the external key module is detected online, the port will be
automatically as a communication port;
2. If there is no the external key module, it will check whether the PIR function is enabled. If the
PIR function is enabled, it will be as the detection port of the PIR;
3. If above cases are not activated, GND and PIR can be used as exit button port.
Main Connect Port: To connect the bus line and the electronic locks.
• L1,L2: Connect to the bus line, no polarity.
• PL: External lock power input, connect to the power positive(power +).
• S+: Lock power(+) output.
• S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door
station to power the locks, if using the external power supply for the locks, the S- will not be
connected).
1 2 3
Lock Control Jumper
3P Connect Port
+12V
GND
PIR
L1 L2
PL
S+ S-
Main Connect Port
3. Install the name plate.
4. Attach the front panel to the rainy cover.
5. Use the special screwdriver and the screws to x the panel.
Terminal Description

-5-
BASIC FUNCTIONS
Unlock Operations
Unlocking of ID Card
When the registered user card has been shown to ID card window, the UNLOCK indicator lights
up, the buzzer sounds,and the electric door strike is unlocked.
• If show the authorized user card,the buzzer will sound of beep+,and the UNLOCK indicator
will light up.
• If show the unauthorized user card,the buzzer will sound of beep,beep,beep.
Fisheye Camera
External Motion Detection
Please note that this function requires the
monitor with sheye function to support.
The angle view is 1700,visitors in this angle
view can be seen clearly and can be zoomed
to see individuals up close via indoor monitor
with sheye function.
The door station is equipped with a terminal to
connect external motion detector.
If the external motion detector is connected
to the system,following functions will be effec-
tive:
If detect someone passing by, the door station
can be activated operation to unlock or turn
on light.
Standard
door station angle
DT608
1700door camera angle
(Wide angle view shown)
12V
Motion
detector
GND
PIR
* Please contact with supplier for more details about
detector connection.

-6-
SETUP INSTRUCTIONS
Functions Setting Up
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_CALL
LED_NAME
Main unit
RF CARD
This section explains the settings of each
function, please refer to the following table:
To perform the settings for the function
you want,you should move away the metal
front panel. Please refer to the sketch
map.
Each operation is indicated by the lighting
up of the LED indicator on the unit, and by
the sounding of the buzzer.
Order Setting items Setting range Default value
1 Setting door station address 0~3 0
2Setting door station
calling mode Standard/Group calling mode Standard calling mode
3 Setting camera N/P standard N/P standard P standard
4 Setting prompt voice Max. 9 voices Voice 1
5 Setting prompt voice volume 1~9 6
6 Setting the unlock mode 0:opened/1:closed 0:opened
7 Setting the unlock time 01 to 99 seconds 1 seconds
8Setting the nameplate
illumination mode On/Off/Auto On
9Setting night view LED
illumination mode On/Off/Auto Auto
10 Setting ring-back tone
Ringing one time
Ring continuously
No ring-back tone
Ringing one time
11 Setting image display mode
Alternate switching mode
Zoom mode
Full screen mode
Alternate switching mode
12 RAINY_COVER congure Provide / not Provide

-7-
Setting Door Station Address
Setting Door Station Calling Mode
Total 4 addresses can be congured. It can be modied either before or after installation.
0 is default, to change the setting, please follow the steps:
UNLOCK Indicator:OFF
TALK Indicator:OFF Buzzer Beep+, Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep+
In standby mode, press
KEY_SET button once
Press KEY_1 button to set
the first door station.
Press KEY_2 button to set
the second door station.
Press KEY_3 button to set
the third door station.
Press KEY_4 button to set
the fourth door station.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep,Beep
ID=0,1st door station ID=1,2nd door station ID=2,3rd door station ID=3,4th door station
SETUP INSTRUCTIONS
• If setting mode has not been exited, you can change the address of door station by pressing KEY1~4
freely.
• The LED_NAME indicator will always blink until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button four times to exit out the setting mode manually.
There are two calling modes for door station.
As apartment system door station, the calling mode is Standard calling mode.
As villa system door station, the calling mode is Group calling mode.
Please know that the door station work in Standard calling mode by default.

-8-
• If setting mode has not been exited, you can change the calling mode by pressing KEY1 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button three times to exit out the setting mode manually.
SETUP INSTRUCTIONS
* More details about code setting for monitor, please refer to corresponding user manual .
Each call button will respond different addresses when set in different calling mode. Refer to the
followings for more informations.
Call buttonA: call the monitor with address 01 by default.
Call buttonB: call the monitor with address 02 by default.
Call buttonC: call the monitor with address 03 by default.
Call buttonD: call the monitor with address 04 by default.
Call buttonE: call the monitor with address 05 by default.
Call buttonF: call the monitor with address 06 by default.
Call buttonG: call the monitor with address 07 by default.
Call buttonH: call the monitor with address 08 by default.
Call buttonA: Call all monitors in group address from
00~15.(one of the monitor should be set to 00)
Call buttonB,C,D,E,F,G,H: Call all monitors in group
address from 16~31. (one of the monitor should be set to
16)
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+
Press KEY_1 button to
activate Standard calling
mode for door station.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep, Beep
Press KEY_1 button again
to activate Group calling
mode for door station.
Press KEY_1
A
B
C
D
E
F
Apartment system
door station
Villa system door station
B
A
G
H
RF CARD
RF CARD
1.Standard calling mode(Address range 01-08 by
default)
2.Group calling mode
To change this setting, please follow the steps:

-9-
Setting Camera N/P Standard
Setting Prompt Voice
The standard of the camera can be adjusted at any time, that means the quality of image on
screen can be set to differ.
P standard is default, to change the setting, please follow the steps:
Max. 9-languages voice to select, No voice, Voice 1 and Voice 2 ...
Voice 1 is default, to change the setting, please follow the steps:
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+
Press KEY_2 button to set the
camera standard to P
standard.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep, Beep
Press KEY_2 button again
to set the camera standard
to N standard.
Press KEY_2
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Play the voice 1
Press KEY_3 button to set the
prompt voice to Voice 1.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Play the voice 2
Press KEY_3 button again
to set the prompt voice to
Voice 2.
Beep+
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer
Press KEY_3 button again
and again to set the prompt
voice to No voice.
Press KEY_3
SETUP INSTRUCTIONS
• If setting mode has not been exited, you can change the camera standard by pressing KEY2 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button three times to exit out the setting mode manually.
• If setting mode has not been exited, you can change the prompt voice by pressing KEY3 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• The voice can be customized.

-10-
SETUP INSTRUCTIONS
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Play the volume
Press KEY_4 button to set the
volume level.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer
Press KEY_4
Play the volume level 9
Press KEY_4 button again
and again to set the volume
level you want.
Setting Unlock Mode
There are 2 unlock modes, Normally opened and Normally closed.
Normally opened is default, to change the setting, please follow the steps:
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+
Press KEY_1 button to set
the unlock mode to
Normally opened.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep, Beep
Press KEY_1 button again
to set the unlock mode to
Normally closed.
Press KEY_1
• If setting mode has not been exited, you can change the unlock mode by pressing KEY1 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button twice to exit out the setting mode manually.
Setting Prompt Voice Volume
• If setting mode has not been exited, you can change the volume level by pressing KEY4 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
Total 9 level can be congured. It can be modied either before or after installation.
6 is default, to change the setting, please follow the steps:
This manual suits for next models
3
Table of contents
Other NY Wholesale Intercom System manuals