Nokeval FD100 Series User manual

FD100 series
User Manual
Nokeval

2
Contents
Document information...................................................................................................................................... 2
FD100A4 and FD100A6 field displays ................................................................................................................ 3
Power supply connection .................................................................................................................................. 4
Configuring ........................................................................................................................................................ 5
Specifications..................................................................................................................................................... 7
Document information
Device Scope: FD100A4 (4-digit device)
FD100A6 (6-digit device)
Case versions: 1.0 to 1.0
Document Type: manual
Document ID: 3103
Document Version: 6
Document Date: 22.12.2011

3
FD100A4 and FD100A6 field displays
Introduction
The FD100 series includes 4 and 6 digit models. Digit size is 100mm. The displays are based on input cards
of the panel meter series 2000 giving over 100 combinations. The unit has wide power supply range of
41...265 VAC or 20...28 VAC/VDC depending on model.
This manual covers enclosure information and installation of the unit. Input cards and programming are
covered in corresponding 2000-series panel meter manual. All 2000-series panel meter combinations are
valid for this series.
Mounting
191
145
100
503 (685)
450 (632)
477, (659) Ø7 mm notch
Ø13.5 mm hole
Dimensions for FD100A6 (6digits)
are shown in brackets
Two cable glands
M20x1.5 mm
Lock for door on sides
The display unit can be mounted with four screws, one at each corner. The diameter of the screw must be
between 5.5 and 6.5 mm. The unit may be mounted to a steel or aluminum structure, to wood with
minimum thickness of 20 mm, or to a material of equivalent or better strength.
To open the case door
There are quick locks on the both sides of the case. The door
can be unlocked by turning side locks towards the rear of the
case.
Warning! Only a qualified electrician is allowed to open the
enclosure.

4
Symbols and markings
Protective earth connector
Alternating or direct current
Power supply connection
The unit has wide power supply range of 41...265 VAC or 20...28 VAC/VDC depending on model. There are
two types of power supply connectors; grey connector color is used to indicate higher voltages and green
color to indicate 24 V.
FD100A4-F48/230 and FD100A6-F48/230
Do not strip the wires more than necessary in order to avoid exposing dangerous voltages. Tie the N and L
wires so that if one of them gets accidentally disconnected, the wire end can't reach the other connectors.
PE - Protective earth.
Free wire length must be
longer than on N and L
lines
Two cable glands
Small display and buttons
for configuration
Electronics
unit
D3
D2
D1
N
L
Power supply
41...265 VAC
Two cable glands

5
FD100A4-F24 and FD100A6-F24
Configuring
The display unit is configured with the small display and buttons inside the main case.
Electronics unit
To reach electronics unit open the main case as explained before. Use the small display and four buttons to
configure the display unit. Programming and input/output connections are explained in 2000-series panel
meter manual for each different device type.
SLOT C
SLOT B
SLOT A
Power supply (Factory connected)
Electronics unit
Buttons and display.
Programming is explained in corresponding 2000-
series panel meter manual.
See corresponding 2000-series
panel meter manual for input and
output connections
D3
D2
D1
24V Power supply
20...28 VAC/VDC
No polarity
Electronics
unit
Small display and buttons
for configuration
Two cable glands

6
Jumper configurations
If corresponding 2000-series manual informs that jumpers need to be changed, see below instructions to
reach the jumpers.
2. Open these 4 screws to open the electronics
case lid to reach internal measurement cards
1. Detach all connectors

7
Specifications
Enclosure
Indoors installation
Allowed
Dimensions
See page 3
Outdoors installation
Allowed
Protection
IP65
Altitude
Max 2000 m
Pollution degree
3
Operating temperature
-10…+50 °C
Weight, 4 digits
5 kg
Storage temperature
-30…+50 °C
Weight, 6 digits
6 kg
Humidity
< 90 %Rh
Power supply
Nominal voltage
20…28 VAC / VDC or
41…285 VAC
depending on model
Pre-fuse (not required)
>2 AT (24V), not required
>1 AT (230V), not required
Frequency
45…65 Hz
Installation category
CAT II
Power
<50 VA
Protection
Enclosure: Class 1,
protective earth. Inputs:
Class 2, reinforced
insulation.
Regulations
Electrical safety EN 61010-1
Classification
Fixed equipment, permanently connected equipment, with protective earth
See additional input and output card specifications from corresponding 2000-series manual.
Nokeval
Nokeval Oy, Yrittäjäkatu 12, 37100 Nokia, Finland,
This manual suits for next models
6
Table of contents
Other Nokeval Monitor manuals