Nira 6B VITON Instructions for use

Nira 6B Hand Pump
Instruction and Maintenance Manual

Copyright © Nira Pumps Oy, 2018 | 3/2018
2

Copyright © Nira Pumps Oy, 2018 | 3/2018
3
Contents
1 Nira 6B ............................................................................................................................................................................ 4
2 Use .................................................................................................................................................................................... 5
2.1 Before using ......................................................................................................................................................... 5
2.2 Installation ........................................................................................................................................................... 5
2.3 Using the pump .................................................................................................................................................. 5
3 Maintenance ................................................................................................................................................................. 6
4 Technical details ......................................................................................................................................................... 9
5 Limited international warranty ......................................................................................................................... 10
6 Frequently asked questions ................................................................................................................................ 11
7 Contact information ................................................................................................................................................ 12
Always read instructions carefully before use.
Familiarise yourself with the parts of the product and any markings before use.

Copyright © Nira Pumps Oy, 2018 | 3/2018
4
1 Nira 6B
The Nira 6B is a high-quality hand pump with primarily rust-proof construction. The 6B is suitable for pumping
liquids such as water*, oil and glycol. Easy to maintain and offering a long service life, the 6B is ideal for
applications such as pumping water for sauna use and pumping oil from tanks. The Nira 6B is available also
with VITON seals for pumping liquids such as petroleum, and EPDM seals for pumping glycol. The Nira 6B
Arctic features ECO seals and is ideal for applications such as pumping fuels in sub-zero conditions.
*not suitable for drinking water
Follow all instructions to avoid damage or injury
The parts of the Nira 6B pump are shown below (Figure 1).
Other product versions Nira 6B
VITON
Nira 6B
EPDM
Nira 6B Arctic
ECO
Flange gasket R611V R611E R611
Shaft seal R603V R603E R603ECO
Plunger seal (1989 and earlier) R56V R56E R56ECO
Plunger seal R606V R606E -
Cylinder seal R604V R604E R604ECO
Bottom valve R609V R609E R609ECO

Copyright © Nira Pumps Oy, 2018 | 3/2018
5
2 Use
2.1 Before using
Before first using the pump please ensure that the packaging is intact and that there are no signs of damage
during transit. Any signs of damage should be reported to the delivery company and to the supplier within two
(2) days of receiving the goods. Ensure that all parts on the packing list are included in the delivery. Contact
the seller immediately if there are any problems with the delivery.
2.2 Installation
The pump is mounted to a vertical surface through the two holes in the pump body. The pump flanges have
either ¾” or 1” threads to which various kinds of suitable pipes or connectors can be fitted. Be sure to check
that all connections are tight.
2.3 Using the pump
The pump is ready for use as soon as it is installed. The pump can lift up to 4 metres without a bottom valve
fitted to the suction line, and up to 8 metres with a bottom valve. Without height differences the length of the
suction pipe can be tens of metres. Please note that the length of the suction pipe and the height difference
between the pump and the water source affect the pumping capacity.
If the pump is used for pumping water and there is a risk of freezing, make sure that the pump is emptied of
water thoroughly after use. If the pump is permanently attached to an oil container make sure that the container
cannot be unintentionally drained through the siphon effect. An accessory designed to prevent draining due
to the siphon effect is available for containers with a 2” internal thread from Nira’s online store (article P61808).
The same pump must not be used for pumping both water and oil
This product is not suitable for pumping drinking water or foodstuffs
Ensure that there is sufficient space around the pump for safe operation
Before using the pump make sure that nothing is in the way of the handle
Ensure that all the parts of the product are firmly fixed in place before use
Check the condition and operation of the pump regularly (at least once a year)
Do not use a defective or leaking pump

Copyright © Nira Pumps Oy, 2018 | 3/2018
6
3 Maintenance
The Nira 6B pump does not require any regular maintenance. This chapter describes the process of changing
the seals in the pump.
The pump should only be serviced or repaired by a capable person
Only use original parts
Before commencing work ensure that the pump is empty of liquid and that the system is not
pressurised
Ensure that all parts are properly tightened after maintenance
Ensure that the pump works as it should after maintenance work
Changing the flange gasket
Changing the bottom valve

Copyright © Nira Pumps Oy, 2018 | 3/2018
7
Changing the cylinder seals
Changing the plunger body and seal (R606)

Copyright © Nira Pumps Oy, 2018 | 3/2018
8
Changing the plunger seal (R56)
Changing the shaft seal

Copyright © Nira Pumps Oy, 2018 | 3/2018
9
4 Technical details
Nira 6B
Material: Cast silumin, steel, stainless steel
Seal material: Nitrile / VITON / EPDM / ECO
Max. Capacity: c. 40l/min
Weight: 3.3kg
Flange threads: ¾” or 1”
Max. pressure: continuous 1 Bar, peak 3 Bar
Packaging dimensions: 500 x 245 x 140mm

Copyright © Nira Pumps Oy, 2018 | 3/2018
10
5 Limited international warranty
The warranty period is determined in the agreement documents. Unless otherwise agreed, the warranty period
for manufacturing and material defects is 2 years.
Warranty Conditions
The warranty is only valid if the warranty demand is presented together with the original invoice or sales slip
or (order) confirmation.
Nira’s obligations are limited to the repair or, at its discretion, replacement of the product or the defective part.
Defective parts shall be replaced with new or equivalent “as new” parts. If necessary, the entire product shall
be exchanged with an identical or functionally identical product. The value of the warranty is always limited to
the value of the defective product. Nira shall not in any event be liable for any direct or indirect consequential
loss. The defective parts removed from a product as part of a warranty case shall become the property of Nira
and shall be retained for by the End Customer for Nira, if necessary. If these parts cannot be returned to Nira
upon request, Nira is entitled to charge for a corresponding amount. When genuine Nira parts are installed in
a Nira product under warranty, only the remaining warranty period of the repaired device applies.
Warranty repairs must be carried out by Nira or authorised Nira dealers. No reimbursement will be made for
repairs carried out by a non-Nira representative, and any such repair work or damage to the products caused
by such repair work will not be covered by this warranty.
This product is not considered to be defective in materials nor workmanship if it requires adaptation in order
to conform to other local or national technical or safety standards.
This warranty covers none of the following:
a) Periodic checks, maintenance and repair or replacement of parts due to normal wear and tear
b) Costs relating to transport, removal or installation of the product;
c) Misuse, including the failure to use this product for its normal purposes or incorrect installation;
d) Damage caused by lightning, water, fire, acts of God, natural catastrophes, war, public disturbances or any
other cause beyond the control of Nira;
e) Spillage of chemicals or liquids, or use of any other hazardous or non-instructed substances, which may
affect the product;
f) Minor defects or deviations from the product specifications which are immaterial, negligible or trivial as
regards to the value or the functioning of the product
Proceeding in a Warranty Case
The following information is an explanation of what you must do in the case of a warranty claim. First, please
contact your Nira dealer and describe the problem (possibly with photographs or videos) and inform Nira of
the product type and date of purchase. Nira’s technicians will help to diagnose defects and malfunctions, and
are often capable of eliminating the malfunction over the phone.
In the event that warranty service is required, you should return the product to the dealer from whom it was
purchased, or directly to Nira’s factory in Finland. In this case, the customer is responsible for the dispatch and
insurance of the product, and the transport and insurance costs shall be borne by the customer. Nira shall
assume the costs for the materials / spare parts and the labour costs as required, as well as the standard
return transportation to the sender. In case of difficulty, details of local dealers are available online at
www.nira.fi. You may also contact the service centre in Finland (e-mail: [email protected]).
This manual suits for next models
3
Table of contents
Other Nira Water Pump manuals
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual