Transport
F1255PC BE should be transported and stored vertically
in a dry place. When being moved into a building,
F1255PC BE may be leant back 45 °.
Caution
The product can be tail heavy.
Remove the outer panels in order to protect them when
moving in confined spaces inside buildings.
EXTRACTING THE COOLING MODULE
To simplify transport and service, the heat pump can be
separated by pulling the cooling module out from the
cabinet.
See page 54 for instructions about the separation.
Assembly
• Position F1255PC BE on a fixed foundation that can
take the weight of the heat pump. Use the product's
adjustable feet to obtain a horizontal and stable set-
up.
30 - 50 mm
30 - 50 mm
15 - 40 mm
• Because water comes from F1255PC BE, the area
where the heating pump is located must be equipped
with floor drainage.
•Install with its back to an outside wall, ideally in a room
where noise does not matter, in order to eliminate
noise problems. If this is not possible, avoid placing
it against a wall behind a bedroom or other room
where noise may be a problem.
• Wherever the unit is located, walls to sound sensitive
rooms should be fitted with sound insulation.
• Route pipes so they are not fixed to an internal wall
that backs on to a bedroom or living room.
INSTALLATION AREA
Leave a free space of 800 mm in front of the product.
Approx. 50 mm free space is required on each side, to
remove the side panels (see image). The panels do not
need to be removed during service. All service on
F1255PC BE can be carried out from the front. Leave
space between the heat pump and the wall behind (and
any routing of supply cables and pipes) to reduce the
risk of any vibration being propagated.
* A normal installation needs 300 – 400 mm (any side) for connection
equipment, i.e. level vessel, valves and electrical equipment.
7Chapter 2 | Delivery and handlingNIBE F1255PC BE
2 Delivery and handling