National Instruments sbRIO-9698 User manual

USER MANUAL AND SPECIFICATIONS
sbRIO-9698
One-Slot C Series and Secondary Ethernet RIO Mezzanine Card
The sbRIO-9698 one-slot C Series RIO Mezzanine Card is an accessory you can use to
connect one board-only C Series module to the NI sbRIO-9607/9627. The sbRIO-9698
includes an Ethernet port for Ethernet communication or EtherCAT master functionality.
Figure 1. sbRIO-9698 Block Diagram
sbRIO RMC Interface Connector
ENET 1
Connector
C Series
Module
3.3 V
Digital I/O
5 V
Power Supply
x 24
Note Board-only C Series modules are designated sbRIO. For example, the
NI 9219 is the enclosed C Series module and the sbRIO-9219 is the board-only
version of the module.
Notice NI makes no electromagnetic compatibility (EMC) or CE marking
compliance claims for the sbRIO-9698. The end-product supplier is responsible for
conformity to any and all compliance requirements.
Notice The sbRIO-9698 must be installed inside a suitable enclosure prior to use.
Hazardous voltages may be present.
Notice Follow proper ESD precautions to ensure you are grounded before
installing hardware.
Notice The protection provided by the sbRIO-9698 can be impaired if the
sbRIO-9698 is used in a manner not described in this document.
Verifying the Kit Contents
Verify that the following items are included in the sbRIO-9698 kit.

Figure 2. sbRIO-9698 Kit Contents
4
3
2
1
6
5
1. M3 × 7 mm Silver Low-Profile Screw (x4)
2. M3 × 4 mm Black Low-Profile Screw (x6)
3. sbRIO-9698
4. C Series Module Support Bracket (x2)
5. Isolator Sheet
6. M3 × 7 mm Standoff (x4)
2| ni.com | sbRIO-9698 User Manual and Specifications

sbRIO-9698 Digital I/O Connector Pinout
J1, DIO
+5V
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
DGND
+5V
DIO22
DIO21
DIO19
DIO18
DIO17
DIO16
DIO23
DIO20
DIO15
DIO14
DIO13
DIO12
DIO11
DIO10
DIO9
DIO8
DIO7
DIO6
DIO5
DIO4
DIO3
DIO2
DIO1
DIO0
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 40
41 42
43 44
45 46
47 48
49 50
Pin 1
Table 1. Signal Descriptions
Signal Description
DGND Ground reference for the digital signal
DIO Digital input/output signal connection
+5 V 5 V power output connection for external devices
Note The DIO numbering on this connector corresponds to naming of the DIO on
the NI sbRIO device. For example, DIO0 on the sbRIO-9698 connector corresponds
to DIO0 on the NI sbRIO-9607/9627 RMC connector.
sbRIO-9698 User Manual and Specifications | © National Instruments | 3

sbRIO-9698 Dimensions
The following figures show the side and rear dimensions of the sbRIO-9698. For two-
dimensional drawings and three-dimensional models of the sbRIO-9698, visit ni.com/
dimensions and search by model number.
Figure 3. Side View with Dimensions
71.7 mm
(2.82 in.)
13.4 mm
(0.53 in.)
9.2 mm
(0.36 in.)
Figure 4. Front View with Dimensions
1
18.0 mm
(0.71 in.)
73.6 mm
(2.90 in.)
1. Recommended Keepaway from Modules
Installing the sbRIO-9698
What to Use
• sbRIO-9698
• sbRIO device
• Socket driver, 4.5 mm
• Screwdriver, Phillips #1
4| ni.com | sbRIO-9698 User Manual and Specifications

What to Do
1. Attach the two C Series support brackets to the sbRIO-9698 using four of the M3 × 4 mm
black, low-profile screws included in the kit.
Note Do not tighten the screws until you reach step 8. You may need to adjust
the brackets during assembly.
Figure 5. Attaching the Support Brackets to the sbRIO-9698
2. Connect board-only C Series modules to the sbRIO-9698.
sbRIO-9698 User Manual and Specifications | © National Instruments | 5

Caution To avoid causing damage to the sbRIO-9698 and the C Series
modules, do not allow C Series module support brackets to contact components
on the secondary side of the board-only C Series modules.
Figure 6. Connecting Board-only C Series Modules to the sbRIO-9698
3. Screw two of the remaining M3 × 4 mm black, low-profile screws into the holes.
Figure 7. Inserting Two Screws into the Module and Bracket Holes
4. Insert the four M3 × 7 mm standoffs from the secondary side of the NI sbRIO device into
the four mounting standoffs for your application. The mounting standoffs are not included
in the sbRIO-9698 kit.
6| ni.com | sbRIO-9698 User Manual and Specifications

Figure 8. Inserting the Standoffs into the NI sbRIO Device
1
2
3
1. M3 × 7 mm Standoff (x4)
2. sbRIO Device
3. Mounting Standoff (x4, Not Provided)
5. Tighten the standoffs to 0.45 N · m (4.0 lb · in.). Do not overtighten.
6. Press the isolator sheet over the standoffs so that 1 mm to 2 mm of standoff protrudes
through the holes.
7. Align the bracket holes attached to the sbRIO-9698 with the tops of the M3 × 7 mm
standoffs, and insert the four M3 × 7 mm silver low-profile screws.
sbRIO-9698 User Manual and Specifications | © National Instruments | 7

Figure 9. Inserting the Standoffs and Screws into the NI sbRIO Device
1
2
3
1. M3 × 7 mm Silver Low-Profile Screw (x4)
2. sbRIO-9698
3. Isolator
8. Tighten all the screws to 0.45 N · m (4.0 lb · in.). Do not overtighten.
sbRIO-9698 Specifications
Caution Do not operate the sbRIO-9698 in a manner not specified in this
document. Product misuse can result in a hazard. You can compromise the safety
protection built into the product if the product is damaged in any way. If the product
is damaged, return it to NI for repair.
8| ni.com | sbRIO-9698 User Manual and Specifications

Definitions
Warranted specifications describe the performance of a model under stated operating
conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating
conditions but are not covered by the model warranty.
•Typical specifications describe the performance met by a majority of models.
•Nominal specifications describe an attribute that is based on design, conformance testing,
or supplemental testing.
Specifications are Typical unless otherwise noted.
3.3 V Digital I/O on 50-Pin IDC Connector
Number of DIO channels 24
Maximum tested current per channel ±3 mA
Input logic levels
Input low voltage, VIL 0 V minimum; 0.8 V maximum
Input high voltage, VIH 2.0 V minimum; 5.25 V maximum
Output logic levels
Output high voltage, VOH
when sourcing 3 mA
2.4 V minimum; 3.465 V maximum
Output low voltage, VOL
when sinking 3 mA
0.0 V minimum; 0.4 V maximum
Network/Ethernet Port
Number of interfaces 1
Network interface 10Base-T, 100Base-TX, and
1000Base-T Ethernet
Compatibility IEEE 802.3
Communication rates 10 Mbps, 100 Mbps,
1000 Mbps auto-negotiated, half-/full-duplex
Maximum cabling distance 100 m/segment
Physical Characteristics
If you need to clean the device, wipe it with a dry towel.
Torque for screws 0.45 N · m (4.0 lb · in)
Weight 39 g (1.4 oz)
sbRIO-9698 User Manual and Specifications | © National Instruments | 9

Environmental
Operating temperature
(IEC 60068-2-1, IEC 60068-2-2)
-40 °C to 85 °C
Thermal validation of an NI sbRIO system assembled with the sbRIO-9698 requires validating
the NI sbRIO device and board-only C Series modules. Measure the operating temperature of
board-only C Series modules 7.6 mm (0.3 in.) above the module surface. Refer to the
documentation of the NI sbRIO device and board-only C Series modules for operating
temperature limits and, if applicable, for typical specifications.
Storage temperature
(IEC 60068-2-1, IEC 60068-2-2)
-40 °C to 85 °C
Operating humidity
(IEC 60068-2-78, IEC 60068-2-2)
10% RH to 90% RH, noncondensing
Storage humidity
(IEC 60068-2-78, IEC 60068-2-2)
5% RH to 95% RH, noncondensing
Maximum altitude 5,000 m
Indoor use only.
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance
information. To obtain product certifications and the DoC for NI products, visit ni.com/
certification, search by model number or product line, and click the appropriate link in the
Certification column.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible
manner. NI recognizes that eliminating certain hazardous substances from our products is
beneficial to the environment and to NI customers.
For additional environmental information, refer to the Minimize Our Environmental Impact
web page at ni.com/environment. This page contains the environmental regulations and
directives with which NI complies, as well as other environmental information not included in
this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of the product life cycle, all NI products must be
disposed of according to local laws and regulations. For more information about
how to recycle NI products in your region, visit ni.com/environment/weee.
10 | ni.com | sbRIO-9698 User Manual and Specifications
Table of contents
Other National Instruments Microcontroller manuals
Popular Microcontroller manuals by other brands

AMS
AMS AS7261 Demo Kit user guide

Novatek
Novatek NT6861 manual

Espressif Systems
Espressif Systems ESP8266 SDK AT Instruction Set

Nuvoton
Nuvoton ISD61S00 ChipCorder Design guide

STMicrolectronics
STMicrolectronics ST7 Assembler Linker user manual

Texas Instruments
Texas Instruments Chipcon CC2420DK user manual

Texas Instruments
Texas Instruments TMS320F2837 D Series Workshop Guide and Lab Manual

CYPRES
CYPRES CY14NVSRAMKIT-001 user guide

Texas Instruments
Texas Instruments INA-DUAL-2AMP-EVM user guide

Espressif Systems
Espressif Systems ESP8266EX Programming guide

Abov
Abov AC33M8128L user manual

Laird
Laird BL654PA user guide