Electricalconnectionsmayonlybemadebyanelectricianwithvalidinstallationauthorizationaccording
tothecurrentregulations.TheAuraelectricheaterissuitableforuseinafamilysauna,one(1)heater
persaunaroom.Retaintheinstallationandoperatinginstructionsforfurtherreference.
UserubbercableH07RN-Fasaconnectioncable.
Controlofelectricheatingwiththeheater:Theelectricheatingcontrolcableisbroughtdirectly
totheheater’sjunctionboxandfurthertotheheater’sterminalblockwitharubbercablethatis
dimensionallyidenticaltotheincomingcable.
Duringtherstheating,theresistorsmayemitfumes.Therefore,ensurethattheroomisproperly
ventilated.NOTE! Please also read the user instructions for the controller!
Alwayscheckthesaunaroombeforeswitchingtheheateron!Alwaysmakesurethatthetimerhas
switchedthepoweroafterthesettimeperiod!
Thetemperatureisadjustedbymeansofthecontroller(seepage15).Theactualheatingtimedepends
onthedimensions,structureandthermalinsulationofthesauna.Thetemperatureinthesaunaroom
canbemaintainedatthedesiredlevelwiththethermostat.Ifthetemperatureofthesaunaroom
becomesdangerouslyhighforanyreason,theoverheatingprotectorwillswitchtheheater’spowero.
Thecauseofoverheatingmustalwaysbeinvestigated.Thepowercanbeswitchedonagainbypressing
theoverheatingprotectorresetbutton(seepage17).
Anexcessiveheatingtimeconsumesenergyanddoesnotimprovethesteamingproperties.Thebest
steamisachievedbykeepingthesauna’sheatingtimerelativelyshort,atabout30–60min.,according
tothesizeofthesaunaandtheheater’spower.Thesizeofthesauna,theglassdoor,windows,or
materialsusedmayrequirealongerheatingtime.