MicroIQ UT User manual

MODELS: UT CT ST
Locker mode instructions
For Office furniture, storage cabinets, lockers, safes, vaults, secured enclosures
TM

1
The factory master code is: 135243
If any there are any errors in executing the steps below
or too much time elapses between the steps, (3x)
and the lock will exit the programming mode.
Getting Started
Two operating modes:
1. Station mode (repeated use with the same code)
2. Locker mode (use with a temporary code)
(green, red, yellow) indicates station mode
(green, yellow, red) indicates locker mode
Note: The is pre-programmed with a factory master code
Operation:
Unlock by entering a valid code. The green LED will illuminate. Turn the knob to unlock.
To lock, enter a four digit code and turn the knob to align the knob pointer with the lock icon on the keypad.
Programming Chart Symbols:
P= press program button
- Solid color indicates LED is lit
-
Indicates LED is flashing
-
- Location to point the key-fob
(Nx)
Indicates flashes N times
1,2,3,4,5 = Indicates the button number to press
Note:
TM
P
Green
Proceed
LED
Red
Error
LED
Yellow
Low battery
LED
Knob
in locked
position
Location to
point the
key-fob
Battery
holder
with cover
Keypad
Program
button
Push thin
front edge
inward
Press
Here
R
The operating mode is specified at the time of order.To determine the lock`s operating mode, remove the battery,
press and release the program button, and reinsert the battery.
Note the color sequence of the LED flashes when the battery is reinserted:
Receives a signal from an electronic
TriTeq key-fob when it is pointed at the
receiver located behind the program button.
Program button:
Infrared Receiver:
Knob:
Moves the lock mechanism from
the locked and unlocked states.
Multiple levels of access:
1.Master code and/or blue control key fob
2.User code
Initiates the programming mode.
When pressed the green LED will illuminate.
P

Locker Mode Programming Instructions:
2
Note: The lock must be unlocked to program in locker mode. User codes are one time use.
CHANGE THE MASTER CODE (6 DIGITS) USING THE FACTORY CODE
112233
Example: 135243 (6x)
Result: Old master code 135243 was erased and new master code 112233 was accepted.
factory master code new master code (6x)
LOCK USING A SINGLE USE USER CODE (4 DIGITS)
Example: 1234
Result: User code 1234 was created and the device was locked
new user code turn knob to lock
turn knob to lock
(every 3 seconds)(3x)
(every 3 seconds)(3x)
CHANGE THE MASTER CODE (6 DIGITS)
Example: 112233 123455
Result: Old master code 112233 was erased and new master code 123455 was accepted.
(6X)
(6x)
old master code new master code
UNLOCK USING A SINGLE USE USER CODE
Example: 1234
Result: User code 1234 was used to unlock the .
Note: The user code created in locker mode is a one time code and is erased when the
is unlocked.
new user code turn knob to unlock
turn knob to unlock
TM
TM
UNLOCK USING THE MASTER CODE
Example: 112233
Result: Master code 112233 was used to unlock the .
Note: If the knob is left in the unlocked position for more than 20 seconds, the user code will
be erased. However, if the is left unlocked for less than 20 seconds, the user code
will not be erased and the device can still be unlocked with that code.
master code
TM
TM

3
Lockout
Double digit codes
To watch the programming videos for the mode please visit:
http://microiqlock.com/station_mode
or the station mode video instructions please visit:
http://microiqlock.com/locker_mode
Switching Modes
Note: The master code is retained when switching modes.
2. Remove the battery for 10 seconds
4. Release the program button
5. Enter the 6 digit master code. When the master code is entered correctly, the yellow LED will illuminate
6. Press button number 2for LOCKER MODE, Press button number 1for STATION MODE
7. Once the lock switches modes, the LED’s will flash in a specific sequence for each mode:
8. Proceed to operate the lock in the selected mode
a)
b)
Locker Mode:
Station Mode:
1. Unlock the and turn the knob to the unlocked position
TM
3. While holding the program button , reinsert the battery and wait until all 3 LED’s
fade in and fade out simultaneously
After 10 consecutive incorrect unlocking attempts, the lock will enter in a “Lockout mode” for two minutes.
While in lockout mode, the operation is temporarily disabled. Each key press will trigger the red LED and the
alert will sound three times. Two minutes after the last key was pressed, the lock will return to normal state and
can be used as intended.
The numbers 6, 7, 8, and 9 can be entered by pressing two keys simultaneously in order to produce a sum.
For example 2 and 4 can be pressed simultaneously to produce the number 6 (2+4=6).
Note: if the code was programmed using 2+4 as the 6 digit, the 2+4 must be used when accessing the lock, because
other combinations that equal six such as 1+5 are distinguished from 2+4.
PROGRAM A CONTROL FOB
Example:
Result: The control fob can now unlock the .
(6x)
master code
123455
point blue control fob at and press the fob button
TM
(6x)
point blue control fob at and press the fob button
UNLOCK USING THE CONTROL FOB
turn knob to unlockPoint the blue control fob at and press the fob button
Note: If the knob is left in the unlocked position for more than 20 seconds, the user code will
be erased. However, if the is left unlocked for less than 20 seconds, the user code
will not be erased and the device can still be unlocked with that code.
TM