1/5 Rev 0 14.12.2005
INSTRUCTION MANUAL FOR COMPRESSORS MGF BABY 6/30 and
6/50
1) GENERAL INFORMATION
Compressor to be used only in dry atmosphere protected against
moisture and water.
In case lammable products are sprayed using compressed air
rom your compressor : ensure proper ventilation o the
workingarea.
Do NOT alter sa ety valve (8) - or pressure regulatorsettings (
inside black box (0) ) to avoid dangerous workingconditions.
In case o abnormal noise, overheating or umes : pull mains out
immediately.
Repairs : should be done by quali ied personnel only or contact
Idee iks vzw
Prior to repair or maintenance : depressurise the compressor – by
means o (4) - and disconnect rom mains.
This compressor is suited or 230 V and 50 Hz. ( not or use in
USA ) and should be connected to an earthed electrical outlet.
2) TRANSPORT
New ompressor pi ked-up at Ideefiks vzw – Obeeliks E-Shop :
The compressor is illed with the right amount o oil
The combined oil/airinlet (1) on the compressorhousing is
closed by means o a PVC stopper.
The air-inlet ilter (1) is packed in a plastic bag and attached to
the oil/airinlet ( rontside o compressorhousing )
Compressormotorblock is blocked or transport with cardboard
strips between motor and casing.
In this described condition the compressor can be transported
in a sa e way.
New ompressor shipped to you by Ideefiks vzw – Obeeliks E-
Shop :
The compressor is NOT illed with oil. Oil is contained in the
package.
The combined oil/airinlet (1) on the compressorhousing is
closed by means o a PVC stopper.
The air-inlet ilter (1) is packed in a plastic bag and attached to
the oil/airinlet ( rontside o compressorhousing )
Compressormotorblock is blocked or transport with cardboard
strips between motor and casing.
The compressed air outletconnectors (6) on the
pressureregulator + manometer (3) are dismounted /
unscrewed and packed separately.
In this described condition the compressor can be transported
or shipped in a sa e way.
Transport of your ompressor :
Remove the air-inlet ilter (1)
Close o the combined oil/airinlet (1) on the
compressormotorblock with the PVC stopper ; this will avoid
any spill o oil.
Keep the compressor in an upright position.
In this described condition the compressor can be transported
in a sa e way.
For extra sa ety the motorblock can be blocked by means o
cardboard strips to be placed between motor and housing.
(4) Drain moisturetrap