MAXIMUM Security Multi Zone User manual

-1–
Multidirectional (1800)
Outdoor/indoor intrusion detector
Multi Zone
®
Guide
www.maximum.co.il

-2–
Table of content
Congratulations ………………………………………………………………………………….. 3
Features ………………………………………………………………………………………….. 3
Description ………………………………………………………………………………………...4
Detection Pattern ……………………………………………………………………..………..5-9
Detection Pattern at 1 meter installation height ……………………………………..5
Detection Pattern at 1.8 meter installation height …………………………………...6
Installation height consideration ........................................................................7, 8
Limiting the detector's horizontal detection angle …………………………………...9
Terminal Block Wiring …………………………………………………………………………..10
Upon connecting Multi-Zone to the power supply …………………………..……………….10
Operation timing of the relays and the LED indicators ……………………………………...11
Preparing the Anti-masking channel for operation (Study Procedure) ……………….11, 12
Programming …………………………………………………………………………………….12
Definition of sensors and sensor groups ……………………………………………13
Programming Table ……………………………………………………………….14-21
The detector full functionality test ……………………………………………………………. 22
Specifications ……………………………………………………………………………………23
Remote Control RM-1 ……………………………………………………………….………..24
Introduction ....................................................................................................24, 25
Power ON/ OFF ...……………………………………………………………………..25
Navigation ……………………………………………………………………………...25
Programming (assigning) a code to the detector ………………………………….26
Entering programming and programming execution ………………………….26, 27
Programming the detector by the Remote Control …………………………….28-34
Displaying the Multi-Zone detector's status reports at the Remote Control …….35
Reading (drawing) the detector's status report to the Remote Control …………35
Saving the detector's status report to the Remote Control memory …………….36
Deleting the detector's status report from the Remote Control memory ………..36
Programming list as appears in the Remote Control ……………………………..37
Specifications of the Power Supply and batteries …………………………………38
Certificate of warranty ……………………………………………………………………...38-40

-3–
Congratulations
We thank you for choosing a product of MAXIMUM Security (1984) Ltd.
Basing on over 30 years experience in R&D and in production of advanced security
systems, we are proud to introduce to you the finest Outdoor/ Indoor motion detector ever
presented, aimed for military, industrial, commercial and residential security.
Please read all parts of this installation and operating manuals and follow the step-by-
step instructions, in order to ensure proper operation and maximal use of all benefits of
the detector.
Features
* Selected horizontal detection angle - up to 1800.
* Multi-Zone includes18 sensors:
- 6 PIR sensors.
- 3 Microwave sensors.
- 8 Anti-masking sensors.
- 1 Shock & Vibration sensor.
* The detector’s features can be programmed by Remote Control (can be purchased
separately).
* The detector can be programmed by means of:
- The detector’s built-in keyboard.
- Remote Control (can be purchased separately).
- External control panel (bus/ communication).
* Three different detection zones. For each zone you can program the following:
- Detection range.
- PIR and Microwave detection sensitivity.
- Pulse Count.
- Anti-masking sensitivity.
* Motion detection of certain direction.
* 8 preset detection programs for selection.
* Relay activation time from 1 second to 99 minutes.
* Relay logics (N.C. / N.O.).
* Pet friendly.
* Option for tone effect upon each detection event.
* Automatic temperature and humidity compensation.
* Waterproof and resistant to bad weather conditions.
* Bracket Free (internal calibration).

-4–
Description
The detector’s name, "Multi-Zone", speaks of its unique character. This motion detector
has six detection zones and unprecedented wide detection angle of up to 1800.
Multi-Zone is highly advanced and accurate. In addition its installation enables saving
expenses for installation of several standard detectors with small angle and detection
capability.

-5–
Detection Pattern
The display shows the vertical position of the PIR sensor groups. The letter indicates the
position of the upper PIR sensor group, while the digit indicates the position of the lower
PIR sensor group.
1
Installation
height:
1meter
Lower sensors
in position # 2:
6 meter range
Lower sensors
in position # 3:
8 meter range
Upper sensors
in position # C:
10 meter range
Lower sensors
in position # 1:
2 meter range
Upper sensors
in position # A:
4 meter range
Upper sensors
in position # B:
7 meter range
2
3
4
5
6
7
8
9
10
11
12 m
Detector
Multi-Zone
Upper sensors
in position # D
Lower sensors
in position # 4
Side view
Grey = Upper PIR sensors
Black = Lower PIR sensors
For 1 meterinstallation height
12m
meter
12 m
meter
12 m
PIR
MW 3
PIR
PIR
Top view
Microwave 2
MW 1

-6–
The display shows the vertical position of the PIR sensor groups. The letter indicates the
position of the upper PIR sensor group, while the digit indicates the position of the lower
PIR sensor group.
For 1.8 meterinstallation height
1
Installation
height:
1.8 meter
Lower sensors
in position # 3:
10 meter range
Lower sensors
in position # 1:
4 meter range
Upper sensors
in position # 2:
7 meter range
2
3
4
5
6
7
8
9
10
11
12 m
Detector
Multi-Zone
Upper sensors
in position # D
Lower sensors
in position # 4
Upper sensors
in position # C:
11 meter range
Upper sensors
in position # B:
8 meter range
Upper sensors
in position # A:
5 meter range
Grey = Upper PIR sensors
Black = Lower PIR sensors
12m
meter
12 m
meter
12 m
PIR
MW 3
PIR
PIR
Top view
Microwave 2
MW 1
Side view

-7–
Installation height consideration
The installation height is between 1 ~ 2 meters. The upper and lower PIR sensor groups
must be moved up or down according to the installation height of the detector (refer to the
table on the next page).
Move up
Move down
Move up
Move down
The display
shows the
vertical position
of the PIR sensor
groups. The letter
indicates the
position of the
upper PIR sensor
group, while the
digit indicates the
position of the
lower PIR sensor
group.

-8–
Move the upper PIR sensor group up or down according to the following table:
Installation Height
Letter indicated
on the Scale
1.0 m
A
1.5 m
B
1.7 m
C
2.0 m
D
Move the Lower PIR sensor up or down according to the following table:
Required declination Angle
Number indicated
on the Scale
00
1
100
2
200
3
300
4
00
100
200
300
4
3
2
1
e
v
e
n
t
.
Declination angel of the lower PIR sensor beam:

-9–
Limiting the detector's horizontal detection angle
Near each one of the six PIR sensors there are plates, which you may move (left and
right) in order to limit the detector's horizontal detection angle.
The plates you my move,
left and right, in order to
limit the detector's
horizontal detection angle.

-10–
Terminal Block Wiring
Terminal Block Wiring Specifications
Terminal No.
Mark on the PCB board
For
1+2
+ -
12 V DC input Power Supply
3+4
COM, IN, OUT
Data communication between the detector and
the control panel.
5+6
MASK
Anti-masking relay.
7+8
RELAY 2
Secondary alarm relay that activates also in
case of shock or vibration detection.
9+10
RELAY 1
Main alarm relay switching on upon movement
detection.
11+12
TAMP
Tamper switch (located in rear and front case).
Upon connecting Multi-Zone to the power supply
Upon connecting Multi-Zone to the power supply, a 60 second countdown begins. When
the countdown ends, 3 short tones will be heard indicating that the detector is now ready
for work.
During the countdown, red, green and yellow LED indicators will blink one after another
on the top of the detector. The display will provide information about the vertical location
of the PIR sensors array (see information on page 7, 8, 12).
In case the power supply is low, red and green LEDs will blink shortly each second.
IN OUT
COM
12 V DC
MASK
RELAY2
RELAY1
TAMP
1
2
3
4
5
6
7
8
9
10
11
12
Table of contents
Other MAXIMUM Security Security Sensor manuals





















