Marvel MA15CRS1XS Manual

Installation
Operation and
Maintenance
Instructions
Ice Machine
MA15CRS1XS

Contents
Intro
Operating Instructions
First Use
Ice
Airflow and Product Loading
Maintenance
Service
Troubleshooting
Warranty
Obtaining Service
Environmental Requirements
Electrical
Cutout Dimensions
Product Dimensions
Side by Side Installation
Water Hookup
General Installation
Grille Installation
Door Swing
Door Adjust
Safety
Safety and Warning
Disposal and Recycling
Installation
Cleaning
Cleaning Condenser
Extended Non-Use
Installation Operation and Maintenance Instructions
2

Welcome to the Marvel Experience
Congratulations on adding a new Marvel crescent ice maker to your home and
thank you for choosing our quality American-built product. You’ll enjoy years of
crescent ice in the comfort and convenience of your home, backed by our full
worry-free warranty. We are thrilled to welcome you to our growing community of
Marvel owners, who trust in our products and our support.
The information in this guide is intended to help you install and maintain your new
Marvel crescent ice maker to protect and prolong the lifetime of your unit. We
encourage you to contact our Technical Support team at (800) 223-3900 with any
questions.
Cheers!
Installation Operation and Maintenance Instructions
3

Safety and Warning
NOTICE
Please read all instructions before installing, operating, or
servicing the appliance.
Use this appliance for its intended purpose only and follow
these general precautions with those listed throughout this
guide:
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a Danger,
Warning or Caution based on the risk type:
!DANGER
Danger means that failure to follow this safety statement
will result in severe personal injury or death.
!WARNING
Warning means that failure to follow this safety statement
could result in serious personal injury or death.
!CAUTION
Caution means that failure to follow this safety statement
may result in minor or moderate personal injury, property
or equipment damage.
!WARNING
CALIFORNIA PROPOSITION 65
This product contains chemicals known to the state of
California to cause cancer and birth defects or other
reproductive harm.
www.P65warnings.CA.gov
Disposal and Recycling
!DANGER
RISK OF CHILD ENTRAPMENT. Before you throw away
your old refrigerator or freezer, take off the doors and leave
shelves in place so children may not easily climb inside.
If the unit is being removed from service for disposal, check and
obey all federal, state and local regulations regarding the
disposal and recycling of refrigeration appliances, and follow
these steps completely:
1. Remove all consumable contents from the unit.
2. Unplug the electrical cord from its socket.
3. Remove the door(s)/drawer(s).
Environmental Requirements
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce the
unit’s ability to reach low temperatures and/or reduce ice
production on applicable models.
For best performance, keep the unit out of direct sunlight and
away from heat generating equipment.
In climates where high humidity and dew points are present,
condensation may appear on outside surfaces. This is
considered normal. The condensation will evaporate when the
humidity drops.
!CAUTION
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
Installation Operation and Maintenance Instructions
4

Electrical
!WARNING
SHOCK HAZARD — Electrical Grounding Required. Never
attempt to repair or perform maintenance on the unit until
the electricity has been disconnected.
Never remove the round grounding prong from the plug
and never use a two-prong grounding adapter.
Altering, cutting or removing power cord, removing power
plug, or direct wiring can cause serious injury, fire, loss of
property and/or life, and will void the warranty.
Never use an extension cord to connect power to the unit.
Always keep your working area dry.
NOTICE
Electrical installation must observe all state and local
codes. This unit requires connection to a grounded
(three-prong), polarized receptacle that has been placed
by a qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz,
15A power supply (normal household current). An individual,
properly grounded branch circuit or circuit breaker is
recommended. A GFCI (ground fault circuit interrupter) is
usually not required for fixed location appliances and is not
recommended for your unit because it could be prone to
nuisance tripping. However, be sure to consult your local codes.
See CUTOUT DIMENSIONS for recommended receptacle
location.
Cutout Dimensions
PREPARE SITE
Your Marvel product has been designed for either free-
standing or built-in installation. When built-in, your unit does
not require additional air space for top, sides, or rear.
However, the front grille must NOT be obstructed, and
clearance is required for an electrical connection in the rear.
!CAUTION
Unit can NOT be installed behind a closed cabinet door.
CUTOUT DIMENSIONS
32"
(813 mm)
to
33"
(838 mm)
15-1/4"
(387 mm)
4"
(102 mm)
7"
mm) (178
5/8"
(16 mm)
Preferred location
for water line and
electrical outlet is in
adjacent cabinet.
Installation Operation and Maintenance Instructions
5
See Electrical
Specifications
for Power Supply
23-3/4"
(603 mm)
Minimum

Product Dimensions
*Add 3/4" To Depth For Water Line Clearance
Installation Operation and Maintenance Instructions
Not Including Handle
6

Installation Operation and Maintenance Instructions
Side-by-Side Installation
Two units may be installed side-by-side.
Cutout width for a side-by-side installation is the cutout
dimension of a single unit times two.
No trim kit is required. However, 1/4" (6 mm) of space needs to
be maintained between the units to ensure unobstructed door
swing.
Units must operate from separate, properly grounded electrical
receptacles placed according to each unit’s electrical
specifications requirements.
Side-by-Side Installation with Bracket
1. Slide both units out so screws on top of units are easily
accessible.
2. Remove screws as shown below.
3. Place bracket over holes and attach to unit with two screws
removed in step 2 using a T-25 Torx driver. Tighten screws
fully.
4. Gently push units into position. Be careful not to entangle
the electrical cord or water line, if applicable.
5. Re-check the leveling, from front to back and side to side.
Make any necessary adjustments. The unit’s top surface
should be approximately 1/8" (3 mm) below the countertop.
7

Installation Operation and Maintenance Instructions
Water Hookup
PREPARE PLUMBING
The water valve uses a standard 1/4" (6.35 mm) compression
fitting.
!CAUTION
Plumbing installation must observe all state and local
codes. All water and drain connections MUST BE made by
a licensed/qualified plumbing contractor. Failure to follow
recommendations and instructions may result in damage
and/or harm.
Water Supply Connection
When connecting the water supply, please note the following:
• Before installing the unit and connecting to the cold water
supply, review the local plumbing codes.
• The water pressure should be between 20 and 120 psi (138
and 827 kPa).
• The water line MUST have a shut-off valve in the supply line.
• The water line should be looped into 2 coils. This will allow
the unit to be removed for cleaning and servicing. Make
certain that the tubing is not pinched or damaged during
installation.
!WARNING
Connect to potable water supply only.
!CAUTION
Do not use any plastic water supply line. The line is under
pressure at all times. Plastic may crack or rupture with age
and cause damage to your home.
Do not use tape or joint compound when attaching a
braided flexible water supply line that includes a rubber
gasket. The gasket provides an adequate seal – other
materials could cause blockage of the valve.
Failure to follow recommendations and instructions may
result in damage and/or harm, flooding or void the product
warranty.
Use new hose set. Do not reuse old hose set.
!CAUTION
Turn off water supply and disconnect electrical supply to
unit prior to installation.
Use caution when handling back panel. The edges could
be sharp.
1. Turn off water supply and disconnect electrical supply to
product prior to attempting installation.
2. Remove the back panel.
8

Installation Operation and Maintenance Instructions
3. Locate water valve inlet.
4. Break away filler feature in bushing with flat screwdriver.
5. Thread water line through back panel hole (with bushing).
6. Locate water valve inlet and connect to valve.
7. Turn on water supply and check for leaks.
8. Reinstall back panel.
9. Install retaining clip.
Remove
ZLWKɠDW
screwdriver
Anti-Tip Bracket
1. Slide unit out so screws on top of unit are easily accessible.
2. Remove the two screws from the opposite side of the hinge
assembly using a T-25 Torx driver (see below).
3. Place bracket over holes and attach to unit with two screws
removed in step 2 using a T-25 Torx driver. Tighten screws
fully.
4. Gently push unit into position. Be careful not to entangle the
electrical cord or water line, if applicable.
5. Check to be sure the unit is level from front to back and side
to side. Make any necessary adjustments. The unit’s top
surface should be approximately 1/8" (3 mm) below the
countertop.
6. Secure bracket into adjoining surface.
9

Installation Operation and Maintenance Instructions
General Installation
LEVELING INFORMATION
1. Use a level to confirm
the unit is level. Level
should be placed
along top edge and
side edge as shown.
2. If the unit is not level,
adjust the legs on the corners of the unit as necessary.
3. Confirm the unit is level after each adjustment and repeat
the previous steps until the unit is level.
INSTALLATION TIP
If the room floor is higher than the floor in the cutout opening,
adjust the rear legs to achieve a total unit rear height of 1/8"
(3 mm) less than the opening’s rear height. Shorten the unit
height in the front by adjusting the front legs. This allows the
unit to be gently tipped into the opening. Readjust the front legs
to level the unit after it is correctly positioned in the opening.
INSTALLATION
1. Plug in the power/electrical cord.
2. Gently push the unit into position. Be careful not to entangle
the cord or water and drain lines.
3. Re-check the leveling, from front to back and side to side.
Make any necessary adjustments. The unit’s top surface
should be approximately 1/8" (3 mm) below the countertop.
4. Install the anti-tip bracket.
5. Remove interior packing material and wipe out the inside of
the unit with a clean, water-dampened cloth.
1
Turn to Adjust
10
Table of contents
Other Marvel Ice Maker manuals

Marvel
Marvel 30iM-BB-O User guide

Marvel
Marvel ML15CRS1XS Manual

Marvel
Marvel 30iM-BS User guide

Marvel
Marvel 25iM-BB-O User guide

Marvel
Marvel 15iM-BB User guide

Marvel
Marvel 25iM-BS User guide

Marvel
Marvel 15IM-BS User guide

Marvel
Marvel MLNP115 User manual

Marvel
Marvel 15iM Manual

Marvel
Marvel MACP215 Series User manual

Marvel
Marvel MA15C Series Manual

Marvel
Marvel 60CIM-SS-F Manual

Marvel
Marvel 15AF Manual

Marvel
Marvel MPCP415-IS01A User manual

Marvel
Marvel MP15C Series Manual

Marvel
Marvel 30iM-BB-F User guide

Marvel
Marvel MACL215-IS01B User manual

Marvel
Marvel 30iMT Assembly instructions

Marvel
Marvel 30iMA-BB User manual

Marvel
Marvel 6OCIM-SS-F User manual