Marani PDA500P User manual

Designed in Italy Assembled in China
DSP Power Amplifier Module
PDA500P
User’s Manual
SEED Guangzhou Electronic LTD. 4F/5F, Build B, No.885, Shenzhou Road, Guangzhou, China Tel:+86 (20) 62845258 - www.marani.com.cn - info@seed-digital.com.cn
Class D 500W+500W or 1kW in BTL with DSP
Vers 1.1

Introduction
Designed in Italy Assembled in China
Marani PDA500P amplifier module provides exceptionally high power density and powerful integrated DSP features,
making it suitable for a broad range of loudspeaker applications. PDA500P amplifier module features analog inputs
with link output; comprehensive DSP functions (crossover, parametric EQ, delay and limiter control); network
control via RS485 on Cat-5 cable .
The lightning ash with arrowhead symbol within an equilateral triangle is intended to alert the
user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may
be of sufficient magnitude to constitute a risk of electric shock to humans.
Important safety instructions
Explanation of Graphical Symbols
The exclamation point within an equilateral triangle is intended to alert the user to the presence
of important operating and maintenance (servicing) instructions in the literature accompanying
Read the information for use (User Manual).
Please keep the User Manual in a safe place during the lifetime of the product. The User Manual forms an integral part of the
product.
Heed all warnings.
Follow all instructions.
Do not use this product near water (for example, in damp rooms or near a swimming pool).
Clean only with dry cloth.
Do not cover the heat sink. Install in accordance with the User Manual.
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.
Protect the power cord from being walked on, pinched or damaged in any other way. Pay particular attention to plugs and the
point where they exit from the Amplifier Unit.
The product may only be used in accordance with the information provided in the User Manual. Before and during the usage of
the amplifier please ensure that all recommendations, especially the safety recommendations in the User Manual, are
adhered to. The Amplifier Unit is designed for the amplification of pulsed audio signals and the Amplifier Unit should only be
connected to speakers with an average impedance that is not lower than the impedances specified in the User's Manual.
PDA500P User Manual

Designed in Italy Assembled in China
Damages that require service:
Unplug the Amplifier Unit from the mains supply and refer to your dealer/distributor or other authorized repair workshop.
Servicing is required when:
- The power-supply cord or plug has been damaged.
- Liquid has been spilled or objects have fallen into the amplifier.
- The amplifier has been exposed to rain or moisture.
- The amplifier has been dropped or suffered damage in any other way.
- The amplifier exhibits a distinct change from its normal function or performance.
Servicing:
Do not attempt to service this product yourself. As opening or removing covers may expose you to dangerous voltage or
other hazards, the amplifier may only be opened by qualified personnel. Please refer to your dealer/distributor.
Servicing and Replacement Parts:
All service and repair work must be carried out by an authorized dealer/distributor. When replacement parts are required,
please ensure that the dealer/distributor only uses replacement parts specified by the manufacturer. The use of
unauthorized replacement parts may result in injury and/or damage through fire or electric shock or other electricity-
related hazards.
Safety Check:
Upon completion of any service or repairs to this product, ask the dealer/distributor to perform safety
checks to determine that the amplifier is in proper operating condition.
Read the information for use (User Manual):
When shipping the product, always use the original shipping carton and packing materials. For maximum
protection, repack the unit as it was originally packed at the factory.
Environments:
Use this product only in E1, E2, E3 or E4 environments according to EN55103-2.
“Electromagnetic compatibility – Product family standard for audio, video and audio-visual entertainment lighting control
apparatus for professional use – Part 2: Immunity”.
Ventilation and heat sink:
The heatsink is provided to ensure reliable operation of the Amplifier Unit and to protect it from overheating. The heat sink
must not be blocked or covered. This product should not be installed unless proper ventilation is provided or manufacturer’s
instructions have been adhered to.
Water and Moisture:
Do not use this product near water (for example, in damp rooms or near a swimming pool).
Cleaning:
Unplug the Amplifier Unit from the wall outlet before cleaning. Do not use liquid or aerosol cleaners.
Power-cord Protection:
Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon them or
against them, paying particular attention to cords and plugs, and the point where they exit from the Amplifier Unit.
Lightning:
For added protection of the product during lightning storms, or when it is left unattended and unused for long periods of
time, unplug it from the wall outlet. This will prevent damage to the product due to lightning and power-line surges.
Disconnection from the mains power supply can only be achieved by removing the plug from the mains socket and by external
disconnection of all poles from the mains.
Interference of external objects and/or liquids with the appliance:
Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short out
parts that could result in a fire or electric shock. Never spill liquid of any kind on the amplifier.
PDA500P User Manual

Designed in Italy Assembled in China
Accessories:
Do not place this product on an unstable cart, stand, tripod, bracket, or table. The product may fall, causing serious injury,
and serious damage to the product. Any mounting of the product should follow the manufacturer’s instructions, and should
use a mounting accessory recommended by the manufacturer.
Connecting:
When you connect the Amplifier Unit to other equipment, turn off the power and unplug all of the equipment from the supply
source. Failure to do so may cause an electric shock and serious personal injury. Read the User's Manual of the other
equipment carefully and follow the instructions when making the connections.
Sound Volume:
Reduce the volume to minimum before you turn on the amplifier to prevent sudden high levels of noise which may cause
hearing or speaker damage.
PDA500P User Manual

Designed in Italy Assembled in China
Overwiev
The PDA500P on the front panel offer the possibility
to select up to 8 presets, edited and uploaded on the
unit through a Rotary encoder.
The Presets can be created thanks a Pc Sw which
controls the unit via a RS485 interface.
The PDA500P can be put in network with twin
modules and controlled within a single Pc interface.
The PDA500P is a powerful Class D BiAmp module for
active cabinets, allowing the user to process the
Input signal with first class 24bit/96kHz DSP
processes, both for filtering purposes and dynamic
ones.
The all DSP processes can be accessed by the
cabinets' manufacturer for the specific acoustic
characterization of the cabinet itself,and by the user
for the application personalization.
For the Cabinets' manufacturers, 5 paramteric filters
(Peaker or Variable Q Shelving) are available on the
Input path of the signl, so as a RMS compressor
operating on both Low/High outputs, and fed by the
Low output path signal.
On the Low/High ways, Lp/Hp filters up to 48dB/Oct
are available, so as up to 15ms Delay, one firs/second
order All Pass filter for phase control purposes, 5
parametric filters (Peaker or Variable Q Shelving ),
RMS compressor and Clip Limiter.
The all processes available to the manufacturers
(Factory) are under Password.
On the PDA500P Panel, a Master Input Gain is
available for the simultaneous level control of the
input level control; 3 leds are indicating the Input
Signal presence, the Limiter activity and the Power
On/Off of the unit.
PDA500P User Manual

Designed in Italy Assembled in China
Main Features
USER Available Processes on the Main Input path
White/Pink Noise Generator
Noise Gate:
Input Gain:
Parametric Equalization:
Filters:
Filter gain:
Center frequency:
Filter Q:
HPF:
Delay
White and Pink Noise Generator with Level controls from -40 up to 0dB
From -80dB up to -50dB Threshold, or Bypass
from -12dB up to 12dB
5 filters assignable as Bell or Shelving
Symmetrical Bell or High/Low Variable Q Shelving
for Bell and Shelving the gain is ranging from -12dBu up to +6dBu by 0.5dBu
resolution steps
selectable with a 1/24th of octave resolution steps from 20Hz up to 20kHz
Q from 0.5 up to 10 by 0.1 resolution steps. Each Filter of the Eq can be
singularly “Bypassed” once set.
from 1st order (Butterworth -6dB/Oct) up to 4th Order (Butterworth, Linkwitz
or Bessel -24dB/Oct)
9.998ms by 10.4us increment/decrement step
FACTORY Available Processes on the LOW/HIGH Input path
X-Over Section:
X-Over Section:
LPF on Outputs:
Filter’s Cutting Frequency
steps
Parametric Equalization:
Filters:
Filter gain:
Center frequency:
Filter Q:
RMS Compressor:
Drive:
Threshold:
Hp/LP Filters up to 48dB/Oct
from 1st order (Butterworth -6dB/Oct) up to 8th Order (Butterworth, Linkwitz
or Bessel -48dB/Oct)
from 1st order (Butterworth -6dB/Oct) up to 8th Order (Butterworth, Linkwitz
or Bessel -48dB/Oct)
1/24th of octave
7 filters assignable as Bell or Shelving
Symmetrical Bell or High/Low Variable Q Shelving
for Bell and Shelving the gain is ranging from -12dBu up to +6dBu by 0.5dBu
resolution steps
selectable with a 1/24th of octave resolution steps from 20Hz up to 20kHz
Q from 0.5 up to 10 by 0.1 resolution steps
Each Filter of the Eq can be singularly “Bypassed” once set.
RMS compressor fed from the Filters section output
from -12dBu up to 6dBu
from 6dBu up to -24dBu
PDA500P User Manual

Designed in Italy Assembled in China
Ratio:
Noise Gate:
IAttack time:
Release time:
Output Volume:
All Pass Filter:
Delay
1:1 (Bypass) up to 100:1 (Limiting), with Ratio Slope computed on Log Table with
0.1dB steps precision
Soft/Hard
Attack time from 5ms up to 100ms (1ms resolution up to 20ms, then 10ms
resolution up to 100ms)
from 0.4 sec up to 1 sec (0.1sec resolution)
from -18dBu up to 18dBu
First (90Deg) and Second (180Deg) order All Pass filters.
The second order All Pass has a variable Q ranging from 0.5 up to 10
9.998ms by 10.4us increment/decrement step
Super User Processes
RMS Compressor:
Drive:
Threshold:
Ratio:
Knee:
Release time
Hold time:
Peak Limiter:
Threshold:
Attack time:
Release time:
RMS compressor fed from the Filters section output
from -12dBu up to 6dBu
from 6dBu up to -24dBu
1:1 (Bypass) up to 100:1 (Limiting), with Ratio Slope computed on Log Table with
0.1dB steps precision
Soft/Hard
Attack time from 1ms up to 3sec (1ms resolution up to 20ms, then 10ms
resolution up to 100ms, then 100ms resolution up to 3sec)
from 40ms sec up to 3 sec (10ms resolution up to 200ms, then 100ms
resolution up to 3sec)
fast PEAK Limiter fed from the all previous processes output
from 12dBu up to -18dBu
Attack time from 1ms up to 100ms (1ms resolution up to 20ms, then 10ms
resolution up to 100ms)
Release time from 40 ms up to 1 sec (10ms resolution up to 200ms, then
100ms resolution up to 1sec)
PDA500P User Manual

Designed in Italy Assembled in China
Operating Mode
The PDA500P can work as a stand alone unit [Stand Alone Mode], where up to 8 preset can be recalled by
directly selecting them through the 8 positions encoder available on the front panel, or can work as completely
remotely controlled unit [Remote Control Mode].
As soon as is turned ON the device will load the currently selected preset, depending from the current
position of the Preset Eq encoder.
The Power Led will turn ON (Red) and the unit will be ready to work.
Stand Alone Mode
When the PDA500P is operating as stand alone unit, so running one of the 8 available presets, previously
created and stored within the unit with the remote control PC SW, the only available control are the 8 “preset
encoder”, allowing to select 1 of the 8 available presets previously stored through the PC SW Remote Control.
In Stand Alone Mode, the only indications of the “Activity” of the PDA500P in terms of running processes and
signal status, can be checked thanks to the Signal Led, indicating if Signal is present at the module Input and
the Limit Led indicating when on, if the DSP is dynamically compressing/Limiting the audio signal and indicating
an Input Clip condition when blinking.
The Input Signal can be sent to the unit through any one of the Male/Female XLR connectors.
The one not used can be used for mirroring the Input signal to an other unit.
The available potentiometer can help to control the Signal Input Level.
Remote Control Mode
When the PDA500P is operating as stand alone unit, so running one of the 8 available presets, previously
created and stored within the unit with the remote control PC SW, the only available control are the 8 “preset
encoder”, allowing to select 1 of the 8 available presets previously stored through the PC SW Remote Control.
In Stand Alone Mode, the only indications of the “Activity” of the PDA500P in terms of running processes and
signal status, can be checked thanks to the Signal Led, indicating if Signal is present at the module Input and
the Limit Led indicating when on, if the DSP is dynamically compressing/Limiting the audio signal and indicating
an Input Clip condition when blinking.
The Input Signal can be sent to the unit through any one of the Male/Female XLR connectors.
The one not used can be used for mirroring the Input signal to an other unit.
The available potentiometer can help to control the Signal Input Level.
PDA500P User Manual

Designed in Italy Assembled in China
PC Sw Remote Control Operations
The PDA500P can be controlled by a Remote Control Sw running on Pc, allowing to fully edit the all processes
available on each channel of the PDA500P.
More, once created the desired configurations and selected the desired processes, the complete set up can
be stored within the PDA500P and recalled later on as preset also when the unit is working in Stand Alone
Mode.
Once launched the Pc Sw Remote Control, previously installed on Pc (for the installation it is enough to run the
“Installation Sw” and to install also the USB driver which installation instruction are on the CD containing the
Remote Control Sw and coming with the PDA500P), the following screen shot will appear on the Pc:
The screen above is allowing to set the RS485 connection parameters.
With the
RS485: the RS485 connection has to be selected when the PDA500P is connected to the PC through the
RS485 line.
In this case the PDA500P will be controlled as one of a NET of chained units, being allowed the net control of
more units when using the RS485 connection.
In the RS485 mode (chosen by “checking” the RS485 button on the “Communication Port” frame), need to
assign the proper “COM” port in order to match the COM port assigned by the Pc to the “USB to Serial Port”
within the Device Manager window at the “Ports (COM&LPT)” directory.
When selected the RS485 connection, more PDA500P can be connected all together.
In order this to happen, need the all units (connected in net and up to 32) to be identified by DIFFERENT ID
number.
In order the units to have a different ID, need to pre-assign to the all units used in net a specific ID number.
When selected the RS485 mode, this can be done connecting one by one the units to be used in net and
assigning to anyone of them an ID through the “Configure ID Device” button.
When a Unit is connected, pressing the “Configure ID Device” it is possible to enter a window allowing to
assign to the unit the ID number.
NOTE: for avoiding problems is highly suggested to work with COM ports number within the 10.
PDA500P User Manual

Designed in Italy Assembled in China
Once selected the desired connection, pressing the “OK” button the Main Environment Window of the Pc Sw
will open:
Double clicking on the Unit's name which processes/parameters have to be edited, the editing environment of
the selected unit will open.
PDA500P User Manual
Table of contents
Other Marani Amplifier manuals