5
MODEL IDE TIFICATIO
A complete measuring system consists of:
1.One code for EC OTEL®series 910 electronics and transducer
2.Optional: code for thread-on mounting flanges, consult factory for other sizes or materials
9 M1 0
APPROVALS/ CABLE ENTRY / OUSING MATERIALS
A Weatherproof – 3/4" NPT dual cable entry, anti-corrosive coated aluminium
VATEX flameproof enclosure – 3/4" NPT dual cable entry, anti-corrosive coated aluminium
W ATEX flameproof enclosure – M20 x 1,5 dual cable entry, anti-corrosive coated aluminium
5 ATEX flameproof enclosure – 3/4" NPT single cable entry, stainless steel
PROCESS CONNECTION - SIZE/TYPE
BASIC MODEL NUMBER
910 Echotel®910, ultrasonic level switch with relay
complete code for Echotel®910
X = product with a specific customer requirement
MA 3/4" NPT
M2 1" NPT
M9 1" BSP (G 1")
Threaded
M1 1" 150 lbs ANSI RF
ME 1" 300 lbs ANSI RF
M 1" 600 lbs ANSI RF
MC 1 1/2" 150 lbs ANSI RF
MF 1 1/2" 300 lbs ANSI RF
MD 2" 150 lbs ANSI RF
MG 2" 300 lbs ANSI RF
MJ 2" 600 lbs ANSI RF
A SI Flanges
M3 1 1/2" Tri-Clamp®
M4 2" Tri-Clamp®
M5 DN 25 DIN 11851
M6 DN 32 DIN 11851
M7 DN 40 DIN 11851
M8 DN 50 DIN 11851
Hygienic
MR
DN 25 PN 16/25/40 EN 1092-1 Type A
MX
DN 25 PN 63/100 EN 1092-1 Type B2
MS
DN 40 PN 16/25/40 EN 1092-1 Type A
MY
DN 40 PN 63/100 EN 1092-1 Type B2
MM
DN 50 PN 16 EN 1092-1 Type A
MT
DN 50 PN 25/40 EN 1092-1 Type A
MW
DN 50 PN 63 EN 1092-1 Type B2
MZ
DN 50 PN 100 EN 1092-1 Type B2
E (DI ) Flanges
ACTUATION LENGT – Specify per cm (0.39") increment
Total insertion length = actuation length + 6 mm (0.25")
00 3 Minimum 3 cm (1.2") – for NPT connections
00 5 Minimum 5 cm (2.0") – for all other connections
25 4 Maximum 254 cm (100.0")
INPUT POWER / RELAY OUTPUT
1 240 V AC/8 A DPDT goldflash relay J 240 V AC/5 A DPDT herm. sealed relay
2224 V DC/8 A DPDT goldflash relay K 224 V DC/5 A DPDT herm. sealed relay
0 120 V AC/8 A DPDT goldflash relay 120 V AC/5 A DPDT herm. sealed relay