Magnetic MPT-333 User manual

Operang Instrucons
Full Height Turnsle
MPT-333 and MPT-353
Doc. ID: 5817,0028EN
Version 01

2
MPT-333 and MPT-353
MAGNETIC AUTOCONTROL GMBH
Grienmatt 20
79650 Schopfheim
Germany
Phone +49 7622 695 5
Fax +49 7622 695 802
www.magnetic-access.com

3
MPT-333 and MPT-353
Contents
Contents
1 Notes on the document 7
1.1 Purpose and contents of this operang instrucons 7
1.2 Read and store the operang instrucons 7
1.3 Non-compliance with the operang instrucons 8
1.4 Symbols and illustraons used in these operang instrucons 8
1.4.1 Warning notes and notes 8
2 Safety 10
2.1 Intended use 10
2.2 Changes and modicaons 10
2.3 Target groups 11
2.3.1 Operator and his responsibilies 11
2.3.2 Personnel - acvies and qualicaons 12
2.4 Personal protecve equipment 13
2.5 Symbols on the device 14
2.6 For your safety 14
2.7 To protect the environment 15
2.8 Emergency opening of the pedestrian gate 15
3 Technical data 16
3.1 Dimensions and design MPT-333 16
3.2 Dimensions and design MPT-353 19
3.3 Electrical connecon 22
3.4 Operang condions 23
3.5 Emissions 23
3.6 Control unit MGC 24
4 Design and funcon 25
4.1 Design MPT-333 25
4.2 Design MPT-353 26
4.3 Funcon 27
4.4 Denions and versions 28
4.4.1 Denions and versions MPT-333 28
4.4.2 Denons and version MPT-353 30

4
MPT-333 and MPT-353
Contents
5 Receipt of goods, transport and storage 32
5.1 Goods receiving department 32
5.2 Safety during transport 32
5.3 Transport 33
5.4 Storage 34
6 Unpacking, scope of delivery and idencaon 35
6.1 Unpacking 35
6.2 Scope of delivery 36
6.3 Idencaon 37
6.3.1 Type plate 37
7 Mounng the MPT-333 38
7.1 Safety during mounng 38
7.2 Mounng opons 39
7.3 Required steps 40
7.4 Specifying the installaon posion 40
7.5 Seng up foundaon and placing empty conduits 40
7.5.1 Requirements foundaon 40
7.5.2 Requirements empty conduits 41
7.5.3 Seng up foundaon and placing empty conduits 42
7.5.4 Foundaon and empty conduit plan
for base frame FURA T3 43
7.5.5 Foundaon and empty conduit plan for direct mounng 45
7.6 Assembling and mounng the base frame 47
7.6.1 Assembling the base frame 47
7.6.2 Assembling the base frame 47
7.7 Preliminary work for installaon directly on the foundaon 49
7.8 Mounng the MPT-333 50
7.8.1 Mounng the locking comb and cage half 50
7.8.2 Mounng the support beam 51
7.8.3 Mounng the centre pillar 53
7.8.4 Closing the cover of the support beam 56
7.9 Checking the assembly 57
8 Mounng the MPT-353 58
8.1 Safety during mounng 58
8.2 Mounng opons 59

5
MPT-333 and MPT-353
Contents
8.3 Required steps 60
8.4 Specifying the installaon posion 60
8.5 Seng up foundaon and placing empty conduits 60
8.5.1 Requirements foundaon 60
8.5.2 Requirements empty conduits 61
8.5.3 Seng up foundaon and placing empty conduits 62
8.5.4 Foundaon and empty conduit plan
for base frame FURA T5 63
8.5.5 Foundaon and empty conduit plan for direct mounng 65
8.6 Mounng the base frame 67
8.7 Preliminary work for installaon directly on the foundaon 69
8.8 Mounng the MPT-353 69
8.8.1 Mounng the cage halves 70
8.8.2 Mounng the support beam 71
8.8.3 Mounng the connecng rods and the centre pillars 73
8.8.4 Mounng the locking combs 80
8.8.5 Closing the cover of the support beam 81
8.9 Checking the assembly 82
9 Mounng the oponal mounng pillar for access-control devices 83
10 Electrical connecon 91
10.1 Safety during electrical connecon 91
10.2 Installing electrical protecve devices 92
10.3 Open and close cover or service door 93
10.3.1 Opening and closing the cover 94
10.3.2 Opening and closing the service door 94
10.4 Connecng the mains cable 95
10.5 Connecng customer control lines 97
10.6 Connecng emergency opening contacts 97
10.7 Installing and connecng customer access-control devices 97
10.8 Checking the electrical connecons 98
11 Commissioning 99
11.1 Safety during commissioning 99
11.2 Pung the pedestrian gate into operaon 99
11.3 Switching the pedestrian gate on and o 100
11.4 Parameterising the pedestrian gate 101

6
MPT-333 and MPT-353
Contents
12 Operaon 101
13 Cleaning and maintenance 101
13.1 Safety during cleaning and maintenance 101
13.2 Cleaning the pedestrian gate 102
13.2.1 Cleaning the pedestrian gate from the outside 102
13.2.2 Cleaning support beam from the inside 103
13.3 Maintenance schedule 104
14 Correcve acon 104
15 Spare parts and repair 105
15.1 Changing and adjusng proximity sensors 105
16 Converng the locking unit 107
16.1 Safety during conversion 107
17 Customer service 111
18 Decommissioning 112
18.1 Safety during decommissioning 112
18.2 Take the pedestrian gate out of operaon 112
19 Disassembly and disposal 113
19.1 Safety during disassembly and disposal 113
19.2 Disassembly and disposal of the system 113
20 EU-Declaraon of Conformity 114
Index 115

7
MPT-333 and MPT-353
Notes on the document
1 Notes on the document
1.1 Purpose and contents of this operang instrucons
These operang instrucons provide all the informaon required for the product in
the various phases of its life cycle.
These operang instrucons contains the following informaon: Assembly and
funcon, transport and storage, unpacking and delivery, installaon and assembly,
electrical connecon, commissioning, operaon, cleaning and maintenance,
decommissioning, dismantling and disposal.
IMPORTANT!
For the parameterisaon of the MGC control unit see separate
document "Descripon of MGC control unit for MPT-333 and MPT-353
Full Height Turnsle (Doc.ID: 5817,0027)".
1.2 Read and store the operang instrucons
Pre-requisite for safe working is the observance of all specied safety notes, warning
notes and instrucons. In addion, the local accident prevenon regulaons,
general safety regulaons and local environmental regulaons applicable to the area
of applicaon of the product must be observed.
Carefully read these operang instrucons before starng any work! The operang
instrucons are a product component and must be kept in direct proximity of the
product, well accessible to the personnel at all mes.
If the product is passed on to third pares, please also provide these operang
instrucons.

8
MPT-333 and MPT-353
Notes on the document
1.3 Non-compliance with the operang instrucons
Magnec declines all liability for personal injury and material damage caused by not
observing the operang instrucons.
This applies in parcular to damage caused by:
› Non-intended use
› Use of non-qualied personnel
› Use of non-approved components
› Unauthorised modicaons
› Inappropriate assembly and installaon
› Improper operaon
› Defecve or unperformed maintenance and repairs
› Use of non-approved spare parts
› Operaon of a faulty product
1.4 Symbols and illustraons used in these operang instrucons
1.4.1 Warning notes and notes
Warning notes are characterised by pictograms in these operang instrucons. A
warning note starts with a signal word that expresses the extent of the hazard.
It is absolutely essenal to observe the warning notes and to proceed with cauon
in order to prevent accidents as well as bodily injuries and property damage.
Warning Notes
DANGER
The signal word DANGER points to an immediately dangerous
situaon, which leads to death or severe injuries if it is not avoided.
WARNING
The signal word WARNING points to a potenally dangerous situaon,
which can lead to death or severe injuries if it is not avoided.

9
MPT-333 and MPT-353
Notes on the document
CAUTION
The signal word CAUTION points to a potenally dangerous situaon,
which can lead to minor injuries if it is not avoided.
NOTICE
The signal word NOTICE points to a potenally harmful situaon,
which leads to property damage if it is not avoided.
Notes and recommendaons
IMPORTANT!
The signal word IMPORTANT highlights useful notes and
recommendaons as well as informaon for an ecient and trouble-
free operaon.

10
MPT-333 and MPT-353
Safety
2 Safety
2.1 Intended use
The MPT-333 Magnec Turnsle and MPT-353 Magnec turnsle are intended only
for access-control of persons from a zone not controlled (ZNC) to a zone controlled
(ZC).
The turnsle is intended for passage of persons who can pass the turnsle safely,
speedily and without any help. Separate access opons are provided for persons
who cannot pass the turnsle safely or without any help, e.g. small children, the
elderly or persons with impairments. Children under 14 years of age may only pass
through the turnsle under the supervision of an adult.
The turnsle may only be mounted on non-ammable oors.
The turnsle may only be operated within the temperature range indicated on the
type plate.
Misapplicaons
Any other or further use is considered improper use. Magnec is not liable for any
resulng personal injury or damage to property.
For example, the following applicaons are considered to be contrary to regulaons:
› Unaccompanied use of the turnsle by children under 14 years of age.
› Use of the turnsle by persons who cannot pass the turnsle safely, quickly or
without assistance.
› Use of the turnsle without cleared passage. This means that the centre pillar is
forced to rotate.
› Mounng the turnsle on a ammable oor.
2.2 Changes and modicaons
Changes or modicaons to the product, aachments or components may result
in unforeseen hazards. Before making any technical changes or modicaons to
the product of any of the components, wrien permission must be obtained from
Magnec.
Other manuals for MPT-333
1
This manual suits for next models
1
Table of contents
Other Magnetic Turnstile manuals
Popular Turnstile manuals by other brands

OZAK
OZAK VP-125 Assembly, Installation and Maintenance Handbook