M-TI 1510A User manual

MTI Part Number 7001-0040
Revision 3.1 – August 7, 2014
1510A
Precision Signal Source with direct digital synthesis
Software Operation Manual
his document discloses subject matter in which MTI Instruments Inc. has proprietary rights and such subject matter shall not, without written permission of MTI
Instruments Inc. be used, released, or disclosed in whole or in part. This legend shall be marked on any reproduction hereof in whole or in part.
MTI Instruments, Inc.
325 Washington Avenue Extension, Albany, New York 12205 USA
█Phone: (518) 218-2550 █FAX: (518) 218-2506
Note:
Performing a user calibration with the
software package will result in an
accuracy of 2% at best. A factory cal
is required to achieve the original
published MTI specifications.

Page i MTI Part Number 7001-0040
Revision 3.1 August 7, 2014
Thank you for purchasing your copy of the
1500 Series Precision Signal Source Software Package
The 1500 Series Precision Signal Source Software Package has
been designed to help you realize the full power of your 1500CS
Precision Calibrator or 1510A Precision Signal Source. Once the
software has been loaded on a standard PC computer and the
communications link installed and connected to the 1500CS
Calibrator, the software package will enable you to perform
many useful maintenance and calibration tasks including:
Setup of the 40 Memory Locations
Manage the configuration of your 1500CS or 1510A
Control of the 1500CS or 1510A output signals from
your computer

Page ii MTI Part Number 7001-0040
Revision 3.1 August 7, 2014
TABLE OF CONTENTS
OVERVIEW
Overview of the 1500 Series Software Package.............................1
Installing the Software ................................................................2
Installing the 1510A USB Driver...................................................3
Before you start the Software ......................................................5
Connecting to your Calibrator ......................................................6
Starting the Software ..................................................................7
TAB FUNCTIONS
Setup.........................................................................................8
Calibration Factors ......................................................................9
Memories .................................................................................10
Memory Labels .........................................................................12
DROP-DOWN MENU FUNCTIONS
Device......................................................................................15
Configuration............................................................................16
Setup.......................................................................................18
Factors.....................................................................................19
Memory....................................................................................20
Tools........................................................................................22
Remote Control Panel...........................................................23
Calibration Wizard................................................................26
Help.........................................................................................41
OPTIONAL ACCESSORIES
Useful System Accessories.........................................................42

Page 1 MTI Part Number 7001-0040
Revision 3.1 August 7, 2014
OVERVIEW OF THE 1500 SERIES SOFTWARE PACKAGE
The 1500 Series Precision Signal Source Software Package is a
perfect companion to your 1500CS Precision Calibrator or 1510A
Precision Signal Source. The package features an easy-to-use
user interface, and offers a number of useful utilities for the
control and maintenance of your 1500 Series Unit. With the
Software Package, you will be able to:
Pre-Program Memory Locations – The 1500CS and 1510A
have 40 memory locations that can hold pre-programmed signal
settings. Each location can be pre-programmed and
downloaded in the unit using this Software Package.
Review Memory Location Programs – The 1500CS and
1510A have 40 memory locations that can hold pre-
programmed signal settings. Each or all of the 40 memory
location settings can be up-loaded from the unit for review and
editing. Changes can then be downloaded back into the unit.
Check Calibrator Configuration – The 1500CS and 1510A
have several internal parameters such as software revision
level, most recent calibration date, and unit serial numbers
stored in its memory. All of these parameters may be viewed
using this Software Package.
Remote Control Of signals – The 1500 Series Precision
Signal Source Software Package also provides an easy to use
interface for controlling the signals generated by the 1500CS via
its RS-232 interface and the 1510A via its USB interface.

Page 2 MTI Part Number 7001-0040
Revision 3.1 August 7, 2014
INSTALLING THE SOFTWARE
The 1500 Series Precision Signal Source Software Package is
supplied on CD-ROM. This software must be installed
before connecting the 1510A Precision Signal Source to
your computer for the first time. Open a Windows Explorer
window to view the contents of the CD.
Double Click on the SETUP.EXE
program to begin the installation
process as illustrated:
As the program installation continues,
a welcome display will be produced,
followed by the License acceptance
display. At the conclusion of the
installation process, the software
loading completion display will appear
as illustrated below.
Click on the FINISH button to
complete the process.
At this time you may also wish to
install a copy of the Acrobat Reader
which is also included on the CD.
Note that the CD also includes a
folder, which contains PDF versions of
both the 1500 Series Users Manual
and a copy of this manual.
If necessary, open the Adobe folder
and install the Adobe Reader
application.
When all software has been installed,
remove the CD from the drive.

Page 3 MTI Part Number 7001-0040
Revision 3.1 August 7, 2014
INSTALLING THE 1510A USB DRIVER
During Setup, the file mti1510A.INF was copied to the
Windows\INF folder on your computer. This file contains
instructions for loading the required USB drivers for the 1510A
Precision Signal Source.
Verify that this file exists. If it does not, manually copy the file from
the USB folder on the CDROM and placed it in your Windows\INF
folder.
After verifying that the INF file exists, connect the USB cable to the
1510A and connect it to a free USB port on your computer.
The Windows Found New Hardware Wizard screen will display.
Select No, not this time
and press Next.
Select Install the
software automatically
(Recommended) and
press Next.
If warned that the driver
has not passed Windows
Logo Testing, press
Continue Anyway.

Page 4 MTI Part Number 7001-0040
Revision 3.1 August 7, 2014
INSTALLING THE 1510A USB DRIVER
continued
When driver installation completes, press
Finish.
Your 1510A is ready for use.
Click Start-Settings-Control Panel and
double click the System icon. When the
System Properties dialog displays, click the
Hardware tab.
Then click the Device Manger button.
In Device Manager, scroll down to the Ports
category and open it. Locate the 1510A
Charge Calibrator entry and note the assigned
COM port. In the next step, the COM port
value must be entered into the program INI
file.
Close the Device Manager.

Page 5 MTI Part Number 7001-0040
Revision 3.1 August 7, 2014
BEFORE YOU START THE SOFTWARE
After installation of the software you will need to check a few items to ensure
efficient operation of all program features.
First, open the file: C:PBS\PbsCalibrator\Program\PbsCalibrator.INI
Verify that the path to the Adobe reader is correct for your system. If not,
replace the correct path within the quotation marks in the INI file and SAVE. If
you do not have Adobe reader installed, the 1500 Series Precision Signal Source
Software Package CDROM contains a copy of the Adobe reader installation
package.
Also verify that the Serial Port number listed in the INI file is correct for your
system. 1=COM1, 2=COM2, etc.
For the 1500CS, set PORT1 to the appropriate serial port number.
For the 1510A, set PORT2 to the port number previously determined from Device
Manager.
Make the necessary changes, SAVE and close the INI file viewer. All other
entries and setting in the file should be left unchanged.
Finally, you may wish to place a shortcut to the program on your
computer desktop. The 1500 Series Precision Signal Source Software
Package program is located in:
C:\PBS\PbsCalibrator\Program\PbsCalibrator.exe

Page 6 MTI Part Number 7001-0040
Revision 3.1 August 7, 2014
CONNECTING TO YOUR CALIBRATOR
Your 1500CS accessory kit includes a communications cable that
connects between the 1500CS Calibrator and your computer via
an RS232 port. MTI Cable 7500-7503 has been designed
specifically to connect between the 1500CS and your computer.
Your 1510A accessory kit includes a communications cable that
connects between the 1510A Precision Signal Source and your
computer via a USB port. MTI Cable 6000-2001 has been
designed specifically to connect between the 1510A and your
computer.
For successful communications ensure that your computer port is
connected as illustrated above.
1500CS
DB9 to RJ12 Cable
MTI P/N 7500-7503
USB Cable
MTI P/N 6000-2001
1510A

Page 7 MTI Part Number 7001-0040
Revision 3.1 August 7, 2014
STARTING THE SOFTWARE
Double clicking on the program icon will launch the 1500 Series
Precision Signal Source Software Program.
An introductory display will first be visible:
Followed by the user interface display:
The following sections of this manual will explain the various
features and functions of the software package.
Table of contents