Lunos e2 mini User manual

I EN Installation Manual
Decentralised Ventilation System with Heat
Recovery
Type e² and e²short
- Please pass on to user -
II FR Instruction d'installation
Ventilation Décentralisée avec Récupération
de Chaleur de Type e² et e²court
- S‘il vous plaît envoyer à l‘utilisateur -

2
Contents Page:
About this manual, Safety instructions 2
Technical specifications, Disposal 2
Dimensional diagrams 3
Installation position, Operating conditions 3
Shipping units, Note on LUNOS outer covers 4
Assembly: Assembly pipe and outside grid 5
Assembly – Electric installation and electric connection 6
Assembly – Assembly of the ventilation insert and the indoor blind 7
Assembly noise absorption set 8
Filter replacement, Cleaning 9
Additional and replacement parts 9
About this manual
Read this manual carefully and completely before assembly. Abide by the general safety instruc-
tions and the safety symbols with information in the text.
Hand out this manual to the user (tenant, proprietors, property management etc.) after completing
assembly.
Symbols in this manual
This symbol is a danger warning in connection with risk of injury.
This symbol is a danger warning in connection with risk of injury from electricity.
Safety instructions
Technical specifications
Beware! Any assembly work to the ventilation device may only be carried out after dis-
connecting all phases of supply voltage! The ventilation device is fitted with protective insulati-
on according to Protection Class II, the protection connection is superfluous!
Attention! The electric connection may only be made by authorised qualified personnel
and according to the applicable version of VDE 0100!
Attention! This device may not be operated by children and persons (filter replacement/
cleaning) who are not able to operate the device safely due to their psychic, sensory or mental
abilities or their inexperience or lack of knowledge. Children should be supervised to ensure
that they do not play with the device.
Device voltage: 12 VDC SELV
Type of protection: IP 22
Volume flow: 18 m³/h - 38 m³/h possible
Measuring sound pressure level 16,5 dB; 19,5 dB
Disposal
Dispose of the packaging correctly sorted. If you want to dispose of the device, abide by the
current rules and regulations. The applicable municipal office will provide information.
Installation Manual EN

3
1m
Dimensional diagrams (all dimensions in mm) EN
Ventilation device
Installation position
Local ventilation devices with heat recovery of the type e² only function in pairs in bidirectional operati-
on. A device operates 70 s (50 s for e² short) in feed air operation, the other 70 s (50 s for e²short) in
exhaust air operation at the corresponding volume flow level as set. Then the air direction is changed.
It is thus ensured that the total of the volume flow admitted is equal to the total of the exhausted volu-
me flow. If a device pair operating in push-pull operation is installed in two different rooms of the flat
and operated, a sufficiently dimensioned interconnection between the air movement must be provided
by overflow air apertures.
Recommended minimum spacing when
installing a pair of devices in a wall:
Recommended minimum spacing when
installing a pair of devices across a corner:
1 m
1,4m
1m
35 300 - 700 17180
180
Dimensions in mm 200 – 300
e²short :
Operating conditions
Temperatur conditions: -15°C to +40°C
Applicable indoor up to 65% relative humidity. During heating period are small condensate formation
possible. If the limitation of use are overstepped, turn of the device and close the indoor blind. Ensure
the gasper supply.
Heat exchanger
Heat
exchanger

4
Shipping units EN
Check the supplies for completeness and perfect conditions
Assembly pipe Outside grid
Heat exchanger unit Indoor blind 9/IBE
Pipe
Protection lid
for cleaning
Type 9/R160 Order No.: 36 765 Type 1/WE180 white Order No.: 39 852
Note on LUNOS outer covers
The full plastic outer covers supplied by LUNOS provide high resistance to driving rain and meet the
requirements of Stress Group III according to DIN 4108-3 (2014-11).
For buildings in wind-exposed locations or if the risk of strong winds and rain on the outer covers,
additional weather protection measures must be taken, if necessary.
Filter (included in the supply unit built-in device e²)
Alternative inner screens see pricelist or on request

5
Further outdoor grids upon request
Assembly – Assembly pipes and outside grid EN
Make the wall openings for the
assembly pipes (e.g. by coring,
core bit Ø 162 mm).
If necessary shorten the pipe to the
required installation length (e²: min.
300 mm; e²short: min. 200 mm).
Take care that the pipe overlaps on
both sides to cope with the plaster
thicknesses (after plastering the
pipe must close flush with the plas-
ter). Insert the pipe and seal it all
around (assembly glue Order No.
038 733).
The product is not inten-
ded for connection to rigid
metal conduit. Only use the
provided plastic pipe.
Apply plaster indoors and outdoors.
When outdoor closure is plastered
first replace the plaster protection lid
outdoors by an outdoor closure
piece.
Remove the plaster protection lid
outdoors. Assemble the outdoor
grid using the integrated claw
fasteners (tighten screws).
①
②
➂
Indoors
Indoors Outdoors
Outdoors
Plaster protective lid
Tighten claw fasteners with screws
3 mm

6
Assembly – Electric installation and electric connection EN
Safety instructions:
Beware! Any assembly work to the ventilation device may only be carried out when all phases
of supply voltage have been disconnected!
Make sure that the supply voltage of all connection lines is dead! (separation from the power
supply with a free space between contacts of at least 3 mm, e.g. all-phase disconnecting electr.
protection).
Each electric circuit of this ventilation system must be fitted with a residual current protection
(e.g. RCD)!
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a.) Installation work and electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards, including fire-rated construction.
b.) Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating
equipment manufacturer’s guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for Heating, Refri-
geration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c.) When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
d.) Ducted fans must always be vented to the outdoors.
e.) If this unit is to be installed over a tub or shower, it must be marked as appropri-
ate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) –
protected branch circuit.
The product’s installation shall not conflict with any requirement in the National Electrical Code,
ANSI/NFPA 70-1999.
Additional installations and electrical components in this ventilation system are prohibited!
The system is controled by Univer-
sal Control 5/UNI or Touch Air
Comfort TAC. Look for the installa-
tion instructions.
Select the position of the switch.
Slit the cable ducts (power cable +
cable to the device pairs). Lay the
power cable (e.g. 3 x AWG18) and
the cables to the pairs of devices
(e.g. 3 x AWG20). Circuit and
switch are connected like the dia-
gramm below.
➃
Power cable
Switch
Device 1
Feed/Exh
Device 2
Exh./Feed
horizontal
vertical
also slit pipes
for cable
Only slit the pipes
in these four areas
Connector box

7
⑤
I III II
0
Important! Set
coding switch to the
functions requested.
In accordance with
installation manual
of 5/UNI. Deviating
coding switch set-
tings are not admis-
sible and lead to
malfunctions!
Series switch
Front view
Universal
control
grey
red
black
red
blue
purple
red
blue
purple
W1 W2
+ 12V
-
rd bl vi rd bl vi
Unit 1;3;5 Unit 2;4;6
From/To To/From
Assembly – Assembly of the ventilation insert and the indoor blind
Remove plaster protection lid
inside, insert heat exchanger unit
into the assembly pipe, ensure
there is a 22 mm spacing. Motor
is on the inside.
Motor
22 mm
⑥
EN

8
Connect cables to plugs, insert
pin and socket connectors into the
recess of the heat exchanger
casing.
⑦Cable Motor cable
red
blue
violet
S1/S2
-
+
Pin-and-socket
connector
S1 - Device 1
S2 - Device 2
Insert indoor closure with filter
casing, snap the indoor blind into
place in open position!
Ready!
open
closed
⑧
Assembly noise absorption set
Can be used as from a pipe
length of 300 mm for e² and
230mm for e²short. Position noise
absorption ring and noise absorp-
tion layer as depicted. The noise
absorption layer can be shorte-
ned if necessary.
Noise absorption ring noise absorption layer
EN

9
Filter replacement EN
The contaminated filter will be signali-
ze. For exact functionality please show
the user manual for Universal Control
5/UNI or Touch Air Comfort TAC. In
other respects do the filter replace-
ment in the following way:
Put the indoor closure off, extract the
filter, insert new or cleaned filter (the
filter cleaning could be made for exa-
mple in a dishwasher), put the indoor
closure on.
The ventilation opening must not de-
livered or covered.
Filter
Please draw up the filter replacement below:
Cleaning
If necessary wipe the indoor blind and covering frame with a dry soft cloth.
Filter replacement and cleaning may neither be carried out by children nor by persons who are
not able to operate the device safely due to their psychic, sensory or mental abilities or their
inexperience or lack of knowledge.
Additional and replacement parts
Indoor blind compl. 9/IBE Order No.: 39 851
Replacement filter G3, 9/FIB3R, pack of 3 Order No.: 37 214
Noise absorption set 9/SW Order No.: 39 850
Wind pressure fuse 9/WDSE (for assembly pipe from 370 mm length) Order No.: 39 860
Acustic insulated frame 9/IBS Order No.: 39 947
LED illuminates beneath the switch
LUNOS Germany
LUNOS Lüftungstechnik GmbH Tel. +49 30 362 001-0
für Raumluftsysteme Fax +49 30 362 001-89
Wilhelmstr. 31 [email protected]
13593 Berlin ∙ Germany www.lunos.de
Filter replacement date Expected filter replacement Type of filter used

10
I EN Installation Manual
Decentralised Ventilation System with Heat
Recovery
Type e² and e²short
- Please pass on to user -
II FR Instruction d'installation
Ventilation Décentralisée avec Récupération
de Chaleur de Type e² et e²court
- S‘il vous plaît envoyer à l‘utilisateur -
Other manuals for e2 mini
5
This manual suits for next models
1
Table of contents
Languages:
Other Lunos Fan manuals

Lunos
Lunos AB 30/60 User manual

Lunos
Lunos e2 mini User manual

Lunos
Lunos e2 mini User manual

Lunos
Lunos Silvento ec User manual

Lunos
Lunos e2 Series User manual

Lunos
Lunos RA 15-60 User manual

Lunos
Lunos e2 neo User manual

Lunos
Lunos Silvento EC User manual

Lunos
Lunos Ne t Series User manual

Lunos
Lunos 9/WDS User manual
Popular Fan manuals by other brands

ELTA FANS
ELTA FANS H03VV-F installation guide

Hunter
Hunter 20714 Owner's guide and installation manual

Emerson
Emerson CARRERA VERANDA CF542ORB00 owner's manual

Hunter
Hunter Caraway Owner's guide and installation manual

Panasonic
Panasonic FV-15NLFS1 Service manual

Kompernass
Kompernass KH 1150 operating instructions