Lumens OIP-D50C User manual

To download the latest version of Quick Start
Guide, multilingual user manual, software, or
driver, etc., please visit Lumens
https://www.MyLumens.com/support
OIP-D50C
AVoIP Controller
User Manual - English
[Important]

1
Table of Contents
Chapter 1 Package Contents...................................................................2
Chapter 2 Instruction before installation................................................3
2.1 Selecting Switch ............................................................................................... 3
2.2 Bandwidth Calculation.................................................................................... 3
Chapter 3 Product Overview....................................................................4
3.1 System Requirements..................................................................................... 4
3.2 I/O functions Introduction............................................................................. 4
3.3 Remote Control ................................................................................................ 5
3.4 IR Pin Assignment............................................................................................ 5
3.5 RS-232 Pin and Default Setting.................................................................... 5
Chapter 4 Installation and Connections.................................................6
4.1 Connection diagram........................................................................................ 6
4.2 Connection Setting.......................................................................................... 6
Chapter 5 Start Using...............................................................................7
5.1 Switch Setting ................................................................................................... 7
Chapter 6 WebGUI Control ......................................................................8
6.1 WebGUI Control Descriptions ...................................................................... 8
6.2 WebGUI Control Menu Descriptions .......................................................... 9
Chapter 7 Troubleshooting....................................................................22
Chapter 8 Safety Instructions................................................................23
Copyright Information...............................................................................24

2
Chapter 1 Package Contents
OIP-D50C Controller
Instruction for
installation
Remote Control
5V/2.6A Power supply
(including a
multinational adapter)
3.5 mm to infrared
extender
Foot mats
(A set of four)
Terminal block
(90°3pin)
Terminal block
(90°5pin)
Terminal block
(180°5pin)
x2
Quick Installation Guide

3
Chapter 2 Instruction before installation
2.1 Selecting Switch
Recommended Brand/Model
Brand
Model
Brand
Model
NETGEAR
S3300 Series
ZyXEL
GS1920
NETGEAR
M4300 Series
ZyXEL
GS2210
D-Link
DGS-1510
ZyXEL
XS3700
Cisco
Catalyst 2960-X
Dell
PowerConnect 5524
EtherWAN
EX26262F
Dell
PowerConnect 2816
2.2 Bandwidth Calculation
The table below summarizes the network bandwidth required for setting resolutions before
installation as a reference
Resolution
Image
Quality
Settings
Maximum
Frame Rate
Average Network
Bandwidth (Mbps)
3840*2160 (2160p30)
Auto
30
218 (146~268)
1920*1080 (1080p)
Auto
60
133 (80~210)
1280*720 (720p)
Auto
60
147 (112~177)
1600*1200 (UXGA)
Auto
60
81 (57~105)
1280*1024 (SXGA)
Auto
60
113 (79~150)
1024*768 (XGA)
Auto
60
81 (72~120)
800*600 (SVGA)
Auto
60
66 (49~82)
640*480 (VGA)
Auto
60
43 (29~56)

4
Chapter 3 Product Overview
3.1 System Requirements
An effective network connection provided by a switch or router, used to connect this product and a
compatible VoIP extender (including encoder and decoder).
An HDMI audio and video equipment, such as a HD TV or screen.
3.2 I/O functions Introduction
3.2.1 Front panel
NO.
Item
Function Descriptions
①
Power indicator
When this light is on, the product is turned on and
connected to the power supply.
②
IR receive window
It only receives the IR signals from the remote control of
this product.
3.2.2 Rear panel
NO.
Item
Function Descriptions
③
IR input port
Connect an IR extender to extend IR to remote devices.
④
RS-232/RS-422/RS
-485 output port
Not supported yet, it is expected to be activated through
firmware update in the future.
⑤
RS-232 input port
This product can be operated via RS-232.
⑥
Contactor input port
Connect to other devices with contactor switch
functions, such as window alarms and door switches. It
can receive up to 8 contactor signals.
⑦
HDMI output port
It can connect to an HDMI display.
⑧
USB port
It can connect a USB keyboard and mouse to operate
the WebGUI control page.
<Remark> Please connect the USB control device
before turning on this product.
⑨
CTRL network port
A computer can operate this product via a network
switch connect device.
⑩
OIP network port
(PoE)
It can connect to a control encoder and decoder.
⑪
Reset-to-default
button
Hold this button for 3 seconds to restart the device and
restore the factory settings.
⑫
Power connector
Plug in the 5V DC power adapter to supply power.

5
3.3 Remote Control
Preset locations 1 ~ 8: Press any key to start the corresponding preset location of that
number.
3.4 IR Pin Assignment
3.5 RS-232 Pin and Default Setting
Default Setting of the Serial Port
Baud Rate
19200
Data Bit
8
Parity Bit
N
Stop Bit
1
Flow Control
N
3-pin Terminal Block
GND
RxD
TxD
IR Extender
IR
Electricity
Ground

6
Chapter 4 Installation and Connections
4.1 Connection diagram
4.2 Connection Setting
This product needs to be equipped with a encoder and decoder at the same time. After the
encoder and decoder are connected, connecting to this product can manage multiple encoders
and decoders through the WebGUI control page.
①Connect the network switch of the same domain as the encoder and decoder to the OIP
network port, so that all OIP devices are in the same local area network.
②Connecting to a HDMI display can check the device status message and access the
WebGUI control page without computer.
③Connect to USB keyboard and mouse.
After completing the above steps, you can use the keyboard and mouse to operate the
WebGUI control page for operations and settings. You can also follow the steps below to
control this product through computer:
④Connect the CTRL network port to the network switch of the same domain as the computer,
so that the D50C controller and the computer are in the same local area network. Enter the
IP address of the controller in the web browser to operate and control the product on the
web page.
⑤Use a 3-pin terminal block to DE-9 terminal cable to connect to a desktop, notebook, or
other serial main control devices, to perform operation through RS-232.
IR
Remote Control
Power Supply
LAN
Control keyboard with
a contactor
LAN
Computers with serial
ports or network ports
RS-232 input
Or
Special Local Area
Network Connection
Network Switch
LAN
Special VoIP Network
Connection
Network Switch
LAN
Contactor
input
HDMI output
VoIP Decoder
VoIP Encoder
LAN
USB hub
HDTV
Keyboard/Mouse
IR input

7
Chapter 5 Start Using
5.1 Switch Setting
Notes
VoIP transmission will consume a lot of bandwidth (high resolutions), and it needs to be paired with
a Gigabit network switch that supports Jumbo Frame and IGMP (Internet Group Management
Protocol) Snooping. It is strongly recommended to be equipped with a switch which includes VLAN
(Virtual Local Area Network) professional network management.
Most consumer-grade routers cannot handle the high traffic flow generated by multicast, so it is not
recommended to directly use the router as your network switch. It is strongly recommended to avoid
mixing your commonly used network traffic with VoIP streaming flow. VoIP streaming flow should at
least use a separate subnet.
Setting Suggestions
Please set Port Frame Size (Jumbo Frame) to 8000.
Please set IGMP Snooping and relevant settings (Port, VLAN, Fast Leave, Querier) to [Enable].

8
Chapter 6 WebGUI Control
6.1 WebGUI Control Descriptions
6.1.1 Control by Connecting a Display
Connect the display to the HDMI output port as well as the keyboard and mouse to the USB port to
see the unlogged WebGUI control page as shown in the figure below. For detailed menu descriptions,
please see 6.2 WebGUI Control Menu Descriptions.
6.1.2 Control via a Web Browser
Open a web browser on the computer and enter the IP address of the CTRL LAN port to see the
unlogged WebGUI control page as shown in the figure below. For detailed menu descriptions, please
see 6.2 WebGUI Control Menu Descriptions.
Even if the user has not logged in, the user can still operate some tabs (Monitor & Control, System).
On the one hand, it allows users to change the existing I/O settings or preset I/O settings at any time.
It also protects other sensitive and critical settings and configuration for you. To log in to the WebGUI
control page, please go to the System tab and click the login button. The default user name and
password are both “admin”. If you control the device with a display but without a keyboard, click the
keyboard icon in the lower right corner to open the keyboard and type in the user name and
password.
<Remark> If you are not sure about the IP address of the CTRL LAN port, please connect the HDMI
display and check the message on the screen.

9
6.2 WebGUI Control Menu Descriptions
6.2.1 Monitor & Control - Image
Description
This tab is to preview the encoder, decoder, and video area in the connection, and you can use drag and drop to
change the signal settings.
No
Item
Function Descriptions
1
Preview of
Encoder Signal
Source
Drag and drop to assign signal sources to different decoders or groups.
2
Preview of
Decoder Video
Area
Display the preview thumbnail of the decoder signals, including the currently available
display groups.
3
Stop
Drag an object to this button and release to stop setting the object.
The thumbnail of the image source will be displayed under normal conditions, and the status icon will be
displayed under the following conditions:
When the encoder is
not currently connected
to the input source.
When the encoder or
decoder does not support
image thumbnails.
When the encoder or decoder is disconnected or not detected by
the main controller.
6.2.2 Monitor & Control –Video Wall
1
2
3
1
2
3
Other manuals for OIP-D50C
1
Table of contents
Popular Gateway manuals by other brands

LST
LST M500RFE-AS Specification sheet

Kinnex
Kinnex Media Gateway quick start guide

2N Telekomunikace
2N Telekomunikace 2N StarGate user manual

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Original instructions

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE user guide

Telsey
Telsey CPVA 500 - SIP Technical manual











